Evaluation of a revised version of computer-assisted diagnosis system, BONENAVI version 2.1.7, for bone scintigraphy in cancer patients

被引:20
|
作者
Koizumi, Mitsuru [1 ]
Miyaji, Noriaki [1 ]
Murata, Taisuke [1 ]
Motegi, Kazuki [1 ]
Miwa, Kenta [1 ]
Koyama, Masamichi [1 ]
Terauchi, Takashi [1 ]
Wagatsuma, Kei [2 ]
Kawakami, Kazunori [3 ]
Richter, Jens [4 ]
机构
[1] Canc Inst Hosp, Dept Nucl Med, Koto Ku, Tokyo 1358550, Japan
[2] Tokyo Metropolitan Inst Gerontol, Res Team Neuroimaging, Itabashi Ku, Tokyo 1730015, Japan
[3] Fujifilm RI Pharma Co Ltd, Chuo Ku, Tokyo 1040031, Japan
[4] EXINI Diagnost AB, S-22370 Lund, Sweden
关键词
Bone scan; Skeletal metastasis; Computer-aided diagnosis; BONENAVI version 2.1.7; PROSTATE-CANCER; SCAN;
D O I
10.1007/s12149-015-0988-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BONENAVI is a computer-assisted diagnosis system that analyzes bone scintigraphy automatically. We experienced more than a few segmentation errors with the previous BONENAVI version (2.0.5). We have since obtained a revised version (2.1.7) and evaluate it. Bone scans of patients were analyzed by BONENAVI version 2.0.5 and a revised version 2.1.7 with regard to segmentation errors, sensitivity, and specificity. Patients with skeletal metastases from prostate cancer, lung cancer, breast cancer, and other cancers were included in the study as true-positive cases. Patients with no skeletal metastasis (regardless of hot spots), and patients with abnormal bone scans but no skeletal metastasis were included as negative cases. Bone-scan patients were subjected to artificial neural network (ANN) evaluation. Values equal to or above 0.5 were regarded as positive, and those below 0.5 as negative. The patients whose clinical status did not correspond to their ANN scores were assessed for any similarities. The frequency of segmentation errors was statistically significantly reduced when using BONENAVI version 2.1.7. The differences in sensitivity and specificity for the results of version 2.0.5 versus version 2.1.7 were not different, giving a high Cohen's kappa coefficient. In the patients who showed an increased ANN value with version 2.1.7, a few false-positive thoracic lesions were identified. Patients whose ANN value was significantly high with version 2.0.5 showed no tendencies. Revised BONENAVI version 2.1.7 for bone scintigraphy was superior with regard to segmentation errors. However, its sensitivity and specificity were similar to those of version 2.0.5. The false-positive identification of thoracic lesions in revised version 2.1.7 might be subject to remedy.
引用
收藏
页码:659 / 665
页数:7
相关论文
共 50 条
  • [31] Diagnostic utility of a computer-aided diagnosis system for whole-body bone scintigraphy to detect bone metastasis in breast cancer patients
    Urano, Misugi
    Maki, Yumi
    Nishikawa, Hiroko
    Kawai, Tatsuya
    Shiraki, Norio
    Shibamoto, Yuta
    ANNALS OF NUCLEAR MEDICINE, 2017, 31 (01) : 40 - 45
  • [32] Diagnostic utility of a computer-aided diagnosis system for whole-body bone scintigraphy to detect bone metastasis in breast cancer patients
    Misugi Urano
    Yumi Maki
    Hiroko Nishikawa
    Tatsuya Kawai
    Norio Shiraki
    Yuta Shibamoto
    Annals of Nuclear Medicine, 2017, 31 : 40 - 45
  • [33] COMPUTER-ASSISTED ADULT MEDICAL DIAGNOSIS - SUBJECT REVIEW AND EVALUATION OF A NEW MICROCOMPUTER-BASED SYSTEM
    WAXMAN, HS
    WORLEY, WE
    MEDICINE, 1990, 69 (03) : 125 - 136
  • [34] A Hybrid LECNN Architecture: A Computer-Assisted Early Diagnosis System for Lung Cancer Using CT Images
    Guraksin, Gur Emre
    Kayadibi, Ismail
    INTERNATIONAL JOURNAL OF COMPUTATIONAL INTELLIGENCE SYSTEMS, 2025, 18 (01)
  • [35] COMPUTER-ASSISTED DIAGNOSIS IN THE NON-INVASIVE EVALUATION OF PATIENTS WITH SUSPECTED CORONARY-ARTERY DISEASE
    DIAMOND, GA
    STANILOFF, HM
    FORRESTER, JS
    POLLOCK, BH
    SWAN, HJC
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1983, 1 (02) : 444 - 445
  • [36] Psychometric Features of the Turkish Version of the Cancer Rehabilitation Evaluation System-Short Form for Patients With Cancer
    Guner, Perihan
    Sar, Vedat
    Pehlivan, Tugba
    JOURNAL OF NURSING MEASUREMENT, 2022, 30 (03) : 482 - 495
  • [37] DEVELOPMENT AND USE OF TOUCH-SCREEN COMPUTER-ASSISTED SELF INTERVIEWING IN PORTUGUESE PATIENTS WITH CHRONIC IMMUNE DISEASES: EVALUATION OF AN ELECTRONIC VERSION OF SF-36V2
    Ribeiro, Claudia
    Moreira, Luis
    Silveira, Augusta
    Silva, Isabel
    Gestal, Juan
    Vasconcelos, Carlos
    ACTA REUMATOLOGICA PORTUGUESA, 2010, 35 (02): : 208 - 214
  • [38] Implementing a computer-assisted telephone interview (CATI) system to increase colorectal cancer screening: A process evaluation
    White, Mary Jo
    Stark, Jennifer R.
    Luckmann, Roger
    Rosal, Milagros C.
    Clemow, Lynn
    Costanza, Mary E.
    PATIENT EDUCATION AND COUNSELING, 2006, 61 (03) : 419 - 428
  • [39] Evaluation of Two Noninvasive Repositioning Systems for Computer-Assisted Oral Implant Surgery in Oral Cancer Patients
    Bodard, Anne-Gaelle
    Paris, Marion
    Salino, Samuel
    Fortin, Thomas
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2010, 23 (05) : 463 - 468
  • [40] Feasibility and acceptability of an audio computer-assisted self-interview version of the Alcohol, Smoking and Substance Involvement Screening Test (ASSIST) in primary care patients
    Spear, Suzanne E.
    Shedlin, Michele
    Gilberti, Brian
    Fiellin, Maya
    McNeely, Jennifer
    SUBSTANCE ABUSE, 2016, 37 (02) : 299 - 305