Evaluation of a revised version of computer-assisted diagnosis system, BONENAVI version 2.1.7, for bone scintigraphy in cancer patients

被引:20
|
作者
Koizumi, Mitsuru [1 ]
Miyaji, Noriaki [1 ]
Murata, Taisuke [1 ]
Motegi, Kazuki [1 ]
Miwa, Kenta [1 ]
Koyama, Masamichi [1 ]
Terauchi, Takashi [1 ]
Wagatsuma, Kei [2 ]
Kawakami, Kazunori [3 ]
Richter, Jens [4 ]
机构
[1] Canc Inst Hosp, Dept Nucl Med, Koto Ku, Tokyo 1358550, Japan
[2] Tokyo Metropolitan Inst Gerontol, Res Team Neuroimaging, Itabashi Ku, Tokyo 1730015, Japan
[3] Fujifilm RI Pharma Co Ltd, Chuo Ku, Tokyo 1040031, Japan
[4] EXINI Diagnost AB, S-22370 Lund, Sweden
关键词
Bone scan; Skeletal metastasis; Computer-aided diagnosis; BONENAVI version 2.1.7; PROSTATE-CANCER; SCAN;
D O I
10.1007/s12149-015-0988-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BONENAVI is a computer-assisted diagnosis system that analyzes bone scintigraphy automatically. We experienced more than a few segmentation errors with the previous BONENAVI version (2.0.5). We have since obtained a revised version (2.1.7) and evaluate it. Bone scans of patients were analyzed by BONENAVI version 2.0.5 and a revised version 2.1.7 with regard to segmentation errors, sensitivity, and specificity. Patients with skeletal metastases from prostate cancer, lung cancer, breast cancer, and other cancers were included in the study as true-positive cases. Patients with no skeletal metastasis (regardless of hot spots), and patients with abnormal bone scans but no skeletal metastasis were included as negative cases. Bone-scan patients were subjected to artificial neural network (ANN) evaluation. Values equal to or above 0.5 were regarded as positive, and those below 0.5 as negative. The patients whose clinical status did not correspond to their ANN scores were assessed for any similarities. The frequency of segmentation errors was statistically significantly reduced when using BONENAVI version 2.1.7. The differences in sensitivity and specificity for the results of version 2.0.5 versus version 2.1.7 were not different, giving a high Cohen's kappa coefficient. In the patients who showed an increased ANN value with version 2.1.7, a few false-positive thoracic lesions were identified. Patients whose ANN value was significantly high with version 2.0.5 showed no tendencies. Revised BONENAVI version 2.1.7 for bone scintigraphy was superior with regard to segmentation errors. However, its sensitivity and specificity were similar to those of version 2.0.5. The false-positive identification of thoracic lesions in revised version 2.1.7 might be subject to remedy.
引用
收藏
页码:659 / 665
页数:7
相关论文
共 50 条
  • [1] Evaluation of a revised version of computer-assisted diagnosis system, BONENAVI version 2.1.7, for bone scintigraphy in cancer patients
    Mitsuru Koizumi
    Noriaki Miyaji
    Taisuke Murata
    Kazuki Motegi
    Kenta Miwa
    Masamichi Koyama
    Takashi Terauchi
    Kei Wagatsuma
    Kazunori Kawakami
    Jens Richter
    Annals of Nuclear Medicine, 2015, 29 : 659 - 665
  • [2] Evaluation of a computer-assisted diagnosis system, BONENAVI version 2, for bone scintigraphy in cancer patients in a routine clinical setting
    Mitsuru Koizumi
    Kei Wagatsuma
    Noriaki Miyaji
    Taisuke Murata
    Kenta Miwa
    Tomohiro Takiguchi
    Tomoko Makino
    Masamichi Koyama
    Annals of Nuclear Medicine, 2015, 29 : 138 - 148
  • [3] Evaluation of a computer-assisted diagnosis system, BONENAVI version 2, for bone scintigraphy in cancer patients in a routine clinical setting
    Koizumi, Mitsuru
    Wagatsuma, Kei
    Miyaji, Noriaki
    Murata, Taisuke
    Miwa, Kenta
    Takiguchi, Tomohiro
    Makino, Tomoko
    Koyama, Masamichi
    ANNALS OF NUCLEAR MEDICINE, 2015, 29 (02) : 138 - 148
  • [4] Diagnostic performance of a computer-assisted diagnostic system: sensitivity of BONENAVI for bone scintigraphy in patients with disseminated skeletal metastasis is not so high
    Koizumi, Mitsuru
    Motegi, Kazuki
    Koyama, Masamichi
    Ishiyama, Mitsutomi
    Togawa, Takashi
    Makino, Tomoko
    Arisaka, Yukiko
    Terauchi, Takashi
    ANNALS OF NUCLEAR MEDICINE, 2020, 34 (03) : 200 - 211
  • [5] Diagnostic performance of a computer-assisted diagnostic system: sensitivity of BONENAVI for bone scintigraphy in patients with disseminated skeletal metastasis is not so high
    Mitsuru Koizumi
    Kazuki Motegi
    Masamichi Koyama
    Mitsutomi Ishiyama
    Takashi Togawa
    Tomoko Makino
    Yukiko Arisaka
    Takashi Terauchi
    Annals of Nuclear Medicine, 2020, 34 : 200 - 211
  • [6] COMPUTER-ASSISTED DIAGNOSIS - SYSTEM EVALUATION
    WAXMAN, HS
    WORLEY, WE
    CLINICAL RESEARCH, 1989, 37 (02): : A784 - A784
  • [7] COMPUTER-ASSISTED DIAGNOSIS - SYSTEM EVALUATION
    WAXMAN, HS
    WORLEY, WE
    CLINICAL RESEARCH, 1990, 38 (02): : A517 - A517
  • [8] Usefulness of novel computer-assisted diagnosis algorithm with bone scintigraphy in CRPC patients with bone metastases.
    Nakayama, Michihiro
    Nomura, Kenta
    Okizaki, Atsutaka
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [9] Evaluation of diagnostic performance of a computer-aided diagnostic system, BONENAVI, on bone scintigraphy images
    Isoda, Takuro
    Baba, Shingo
    Maruoka, Yasuhiro
    Kitamura, Yoshiyuki
    Sasaki, Masayuki
    Honda, Hiroshi
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [10] Prediction of survival in prostate cancer patients by bone scan index using computer-assisted diagnosis system
    Yoshimura, M.
    Takahashi, Y.
    Uchida, K.
    Suzuki, K.
    Hashimoto, T.
    Funatsu, T.
    Yoshimura, N.
    Park, J.
    Saguchi, T.
    Saito, K.
    Tokuuye, K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S414 - S414