Direct quantification of aromatic hydrocarbons in geochemical fluids with a mid-infrared attenuated total reflection sensor

被引:34
|
作者
Pejcic, Bobby [1 ]
Boyd, Leigh [2 ]
Myers, Matthew [1 ]
Ross, Andrew [1 ]
Raichlin, Yosef [3 ]
Katzir, Abraham [3 ]
Lu, Rui [4 ,5 ]
Mizaikoff, Boris [4 ]
机构
[1] CSIRO, Earth Sci & Resource Engn, Wealth Oceans Flagship, Kensington, WA 6151, Australia
[2] Natl Measurement Inst, Perth, WA 6151, Australia
[3] Tel Aviv Univ, Sch Phys & Astron, IL-69978 Tel Aviv, Israel
[4] Univ Ulm, Inst Analyt & Bioanalyt Chem, D-89081 Ulm, Germany
[5] Univ Sci & Technol China, Dept Chem, Hefei 230026, Peoples R China
关键词
CRYSTAL MICROBALANCE SENSOR; VOLATILE ORGANIC-COMPOUNDS; MARINE-ENVIRONMENT; INFRARED DETECTION; CHLORINATED HYDROCARBONS; AQUEOUS-SOLUTIONS; CHEMICAL SENSOR; WAVE-GUIDES; CRUDE OILS; WATER;
D O I
10.1016/j.orggeochem.2012.11.011
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
An improved analytical method for directly and rapidly quantifying various monocyclic and polycyclic aromatic molecules in oil-water mixtures has been developed. This study reports on the application of a sensor based on attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) for determining the concentration of a number of volatile organic compounds (VOCs) and polycyclic aromatic hydrocarbons (PAHs) in water. The mid-infrared (MIR) sensor consists of a zinc selenide (ZnSe) waveguide with the surface modified by a thin poly(isobutylene) (PIB) coating. The sensitivity was investigated at different polymer film thicknesses and molecular weights. The analytical performance of the sensor was validated in the laboratory against a standard analytical technique for analyzing petroleum based samples. We have shown that the sensor may accurately quantify the benzene, toluene, ethylbenzene, xylenes and naphthalene (BTEXN) concentration in an oil-water mixture. The ATR-FTIR method overcomes the limitations associated with sampling/sample preparation and has the advantage that it may easily discriminate between meta-and para-xylene, which is difficult with conventional analytical techniques (i.e., GC). In addition, this technology may potentially be deployed in the field for geochemical mapping and to monitor in situ the concentration profile of a number of hydrocarbons in geological formations (e.g., petroleum systems). To demonstrate this, a miniaturized prototype of an ATR-IR sensor system taking advantage of planar-tapered silver halide fibers has been developed and tested. Crown Copyright (C) 2012 Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:63 / 71
页数:9
相关论文
共 50 条
  • [41] A comparative study of mid-infrared diffuse reflection (DR) and attenuated total reflection (ATR) spectroscopy for the detection of fungal infection on RWA2-corn
    Kos, G
    Krska, R
    Lohninger, H
    Griffiths, PR
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (01) : 159 - 166
  • [42] A comparative study of mid-infrared diffuse reflection (DR) and attenuated total reflection (ATR) spectroscopy for the detection of fungal infection on RWA2-corn
    Gregor Kos
    Rudolf Krska
    Hans Lohninger
    Peter R. Griffiths
    Analytical and Bioanalytical Chemistry, 2004, 378 : 159 - 166
  • [43] Mid-infrared attenuated total reflectance spectroscopy for soil carbon and particle size determination
    Ge, Yufeng
    Thomasson, J. Alex
    Morgan, Cristine L. S.
    GEODERMA, 2014, 213 : 57 - 63
  • [44] Anharmonicity in the mid-infrared spectra of polycyclic aromatic hydrocarbons: molecular beam spectroscopy and calculations
    Lemmens, A. K.
    Rap, D. B.
    Thunnissen, J. M. M.
    Mackie, C. J.
    Candian, A.
    Tielens, A. G. G. M.
    Rijs, A. M.
    Buma, W. J.
    ASTRONOMY & ASTROPHYSICS, 2019, 628
  • [45] Application of Mid-Infrared Attenuated Total Reflectance Spectroscopy Using Broadly Tunable OPOs
    Nieuwenhuis, A. F.
    Lee, C. J.
    van der Slot, P. J. M.
    Lindsay, I. D.
    Gross, P.
    Boller, K. -J.
    2008 CONFERENCE ON LASERS AND ELECTRO-OPTICS & QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE, VOLS 1-9, 2008, : 1748 - +
  • [46] Probing computational methodologies in predicting mid-infrared spectra for large polycyclic aromatic hydrocarbons
    Kerkeni, B.
    Garcia-Bernete, I
    Rigopoulou, D.
    Tew, D. P.
    Roche, P. F.
    Clary, D. C.
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 2022, 513 (03) : 3663 - 3681
  • [47] Anharmonicity in the mid-infrared spectra of polycyclic aromatic hydrocarbons: Molecular beam spectroscopy and calculations
    Lemmens, A.K.
    Rap, D.B.
    Thunnissen, J.M.M.
    MacKie, C.J.
    Candian, A.
    Tielens, A.G.G.M.
    Rijs, A.M.
    Buma, W.J.
    Astronomy and Astrophysics, 2019, 628
  • [48] Mid-infrared spectroscopy-based antibody aggregate quantification in cell culture fluids
    Capito, Florian
    Skudas, Romas
    Kolmar, Harald
    Hunzinger, Christian
    BIOTECHNOLOGY JOURNAL, 2013, 8 (08) : 912 - U48
  • [49] New tool for epidermal and cosmetic formulation studies by attenuated total-reflection spectroscopy using a flexible mid-infrared fiber probe
    H. Heise
    L. Küpper
    W. Pittermann
    L. Butvina
    Fresenius’ Journal of Analytical Chemistry, 2001, 371 : 753 - 757
  • [50] Epidermal in vivo and in vitro studies by attenuated total reflection mid-infrared spectroscopy using flexible silver halide fibre-probes
    Heise, HM
    Küpper, L
    Pittermann, W
    Stücker, M
    JOURNAL OF MOLECULAR STRUCTURE, 2003, 651 : 127 - 132