Direct quantification of aromatic hydrocarbons in geochemical fluids with a mid-infrared attenuated total reflection sensor

被引:34
|
作者
Pejcic, Bobby [1 ]
Boyd, Leigh [2 ]
Myers, Matthew [1 ]
Ross, Andrew [1 ]
Raichlin, Yosef [3 ]
Katzir, Abraham [3 ]
Lu, Rui [4 ,5 ]
Mizaikoff, Boris [4 ]
机构
[1] CSIRO, Earth Sci & Resource Engn, Wealth Oceans Flagship, Kensington, WA 6151, Australia
[2] Natl Measurement Inst, Perth, WA 6151, Australia
[3] Tel Aviv Univ, Sch Phys & Astron, IL-69978 Tel Aviv, Israel
[4] Univ Ulm, Inst Analyt & Bioanalyt Chem, D-89081 Ulm, Germany
[5] Univ Sci & Technol China, Dept Chem, Hefei 230026, Peoples R China
关键词
CRYSTAL MICROBALANCE SENSOR; VOLATILE ORGANIC-COMPOUNDS; MARINE-ENVIRONMENT; INFRARED DETECTION; CHLORINATED HYDROCARBONS; AQUEOUS-SOLUTIONS; CHEMICAL SENSOR; WAVE-GUIDES; CRUDE OILS; WATER;
D O I
10.1016/j.orggeochem.2012.11.011
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
An improved analytical method for directly and rapidly quantifying various monocyclic and polycyclic aromatic molecules in oil-water mixtures has been developed. This study reports on the application of a sensor based on attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) for determining the concentration of a number of volatile organic compounds (VOCs) and polycyclic aromatic hydrocarbons (PAHs) in water. The mid-infrared (MIR) sensor consists of a zinc selenide (ZnSe) waveguide with the surface modified by a thin poly(isobutylene) (PIB) coating. The sensitivity was investigated at different polymer film thicknesses and molecular weights. The analytical performance of the sensor was validated in the laboratory against a standard analytical technique for analyzing petroleum based samples. We have shown that the sensor may accurately quantify the benzene, toluene, ethylbenzene, xylenes and naphthalene (BTEXN) concentration in an oil-water mixture. The ATR-FTIR method overcomes the limitations associated with sampling/sample preparation and has the advantage that it may easily discriminate between meta-and para-xylene, which is difficult with conventional analytical techniques (i.e., GC). In addition, this technology may potentially be deployed in the field for geochemical mapping and to monitor in situ the concentration profile of a number of hydrocarbons in geological formations (e.g., petroleum systems). To demonstrate this, a miniaturized prototype of an ATR-IR sensor system taking advantage of planar-tapered silver halide fibers has been developed and tested. Crown Copyright (C) 2012 Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:63 / 71
页数:9
相关论文
共 50 条
  • [21] Screening of Wolbachia Endosymbiont Infection in Aedes aegypti Mosquitoes Using Attenuated Total Reflection Mid-Infrared Spectroscopy
    Khoshmanesh, Aazam
    Christensen, Dale
    Perez-Guaita, David
    Iturbe-Ormaetxe, Inaki
    O'Neill, Scott L.
    McNaughton, Don
    Wood, Bayden R.
    ANALYTICAL CHEMISTRY, 2017, 89 (10) : 5285 - 5293
  • [22] Attenuated Total Reflection Mid-Infrared (ATR-MIR) Spectroscopy and Chemometrics for the Identification and Classification of Commercial Tannins
    Ricci, Arianna
    Parpinello, Giuseppina P.
    Olejar, Kenneth J.
    Kilmartin, Paul A.
    Versari, Andrea
    APPLIED SPECTROSCOPY, 2015, 69 (11) : 1243 - 1250
  • [23] Development of a method for the determination of Fusarium fungi on corn using mid-infrared spectroscopy with attenuated total reflection and chemometrics
    Kos, G
    Lohninger, H
    Krska, R
    ANALYTICAL CHEMISTRY, 2003, 75 (05) : 1211 - 1217
  • [24] Soil Nutrient Detection Method Based on Combining Mid-Infrared Attenuated Total Reflection and Diffuse Reflectance Spectroscopy
    Chen Chen
    Li Zhi-wei
    Dong Da-ming
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37 (11) : 3557 - 3561
  • [25] Toward Chalcogenide Platform Infrared Sensor Dedicated to the In Situ Detection of Aromatic Hydrocarbons in Natural Waters via an Attenuated Total Reflection Spectroscopy Study
    Baillieul, Marion
    Baudet, Emeline
    Michel, Karine
    Moreau, Jonathan
    Nemec, Petr
    Boukerma, Kada
    Colas, Florent
    Charrier, Joel
    Bureau, Bruno
    Rinnert, Emmanuel
    Nazabal, Virginie
    SENSORS, 2021, 21 (07)
  • [26] Preparation and transmission characteristics of a mid-infrared attenuated total reflection hollow waveguide based on a stainless steel capillary tube
    Wang, Xu
    Guo, Hong
    Wang, Lin
    Yue, Fangyu
    Jing, Chengbin
    Chu, Junhao
    APPLIED OPTICS, 2016, 55 (23) : 6404 - 6409
  • [27] Mid-infrared fiber-optic attenuated total reflection spectroscopy of the solid-liquid phase transition of water
    Millo, A
    Raichlin, Y
    Katzir, A
    APPLIED SPECTROSCOPY, 2005, 59 (04) : 460 - 466
  • [28] The influence of wetting and drying cycles on mid-infrared attenuated total reflection spectra of quartz: Understanding spectroscopy of disturbed soil
    Karlowatz, M
    Aleksandrov, A
    Orlando, T
    Cathcart, JM
    Mizaikoff, B
    DETECTION AND REMEDIATION TECHNOLOGIES FOR MINES AND MINELIKE TARGETS IX, PTS 1 AND 2, 2004, 5415 : 629 - 637
  • [29] Attenuated total reflectance Fourier transform mid-infrared spectroscopic quantification of sorbitol and sorbose during a Gluconobacter biotransformation process
    Macauley-Patrick, S
    Arnold, SA
    McCarthy, B
    Harvey, LM
    McNeil, B
    BIOTECHNOLOGY LETTERS, 2003, 25 (03) : 257 - 260
  • [30] Attenuated total reflectance Fourier transform mid-infrared spectroscopic quantification of sorbitol and sorbose during a Gluconobacter biotransformation process
    Sue Macauley-Patrick
    S. Alison Arnold
    Brendan McCarthy
    Linda M. Harvey
    Brian McNeil
    Biotechnology Letters, 2003, 25 : 257 - 260