The relationship between measurement method and corneal structure on apparent intraocular pressure in glaucoma and ocular hypertension

被引:9
|
作者
Nessim, Maged [1 ]
Mollan, Susan P. [2 ]
Wolffsohn, James S. [3 ]
Laiquzzaman, Mohammad [4 ]
Sivakumar, Subramaniam [4 ]
Hartley, Stephanie [1 ]
Shah, Sunil [1 ,3 ,4 ]
机构
[1] City Hosp, Birmingham & Midland Eye Ctr, Birmingham B18 7QH, W Midlands, England
[2] Univ Hosp Birmingham NHS Trust, Queen Elizabeth Hosp, Dept Ophthalmol, Birmingham B15 2WB, W Midlands, England
[3] Aston Univ, Ophthalm Res Grp, Birmingham B4 7ET, W Midlands, England
[4] Heart England NHS Fdn Trust, Solihull Hosp, Birmingham B91 2JL, W Midlands, England
来源
CONTACT LENS & ANTERIOR EYE | 2013年 / 36卷 / 02期
关键词
Cornea; Intraocular pressure; Glaucoma; open angle; Ocular hypertension; Ocular tonometry; GOLDMANN APPLANATION TONOMETRY; DYNAMIC CONTOUR TONOMETRY; OPEN-ANGLE GLAUCOMA; NORMAL-TENSION GLAUCOMA; RESPONSE ANALYZER; BIOMECHANICAL PROPERTIES; NONCONTACT TONOMETRY; THICKNESS; HYSTERESIS; REDUCTION;
D O I
10.1016/j.clae.2012.11.001
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To analyse the relationship between measured intraocular pressure (IOP) and central corneal thickness (CCT), corneal hysteresis (CH) and corneal resistance factor (CRF) in ocular hypertension (OHT), primary open-angle (POAG) and normal tension glaucoma (NTG) eyes using multiple tonometry devices. Methods: Right eyes of patients diagnosed with OHT (n=47), normal tension glaucoma (n=17) and POAG (n=50) were assessed, IOP was measured in random order with four devices: Goldmann applanation tonometry (GAT); Pascal(R) dynamic contour tonometer (DCT); Reichert(R) ocular response analyser (ORA); and Tono-Pen(R) XL. CCT was then measured using a hand-held ultrasonic pachymeter. CH and CRF were derived from the air pressure to corneal reflectance relationship of the ORA data. Results: Compared to the GAT, the Tonopen and ORA Goldmann equivalent (IOPg) and corneal compensated (IOPcc) measured higher IOP readings (F=19.351, p<0.001), particularly in NTG (F=12.604, p<0.001). DCT was closest to Goldmann IOP and had the lowest variance. CCT was significantly different (F=8.305, p<0.001) between the 3 conditions as was CH (F=6.854, p=0.002) and CRF (F=19.653, p<0.001). IOPcc measures were not affected by CCT. The DCT was generally not affected by corneal biomechanical factors. Conclusion: This study suggests that as the true pressure of the eye cannot be determined non-invasively, measurements from any tonometer should be interpreted with care, particularly when alterations in the corneal tissue are suspected. (C) 2012 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:57 / 61
页数:5
相关论文
共 50 条
  • [31] Effect of Beclomethasone Nasal Spray on Intraocular Pressure in Ocular Hypertension or Controlled Glaucoma
    Yuen, Darana
    Buys, Yvonne M.
    Jin, Ya-Ping
    Alasbali, Tariq
    Trope, Graham E.
    JOURNAL OF GLAUCOMA, 2013, 22 (02) : 84 - 87
  • [32] Mean intraocular pressure and progression based on corneal thickness in patients with ocular hypertension
    A G P Konstas
    M T Irkec
    M A Teus
    B Cvenkel
    Y S Astakhov
    E D Sharpe
    G Hollo
    N Mylopoulos
    B Bozkurt
    C Pizzamiglio
    V V Potyomkin
    A M Alemu
    Q J Nasser
    J A Stewart
    W C Stewart
    Eye, 2009, 23 : 73 - 78
  • [33] Mean intraocular pressure and progression based on corneal thickness in patients with ocular hypertension
    Konstas, A. G. P.
    Irkec, M. T.
    Teus, M. A.
    Cvenkel, B.
    Astakhov, Y. S.
    Sharpe, E. D.
    Hollo, G.
    Mylopoulos, N.
    Bozkurt, B.
    Pizzamiglio, C.
    Potyomkin, V. V.
    Alemu, A. M.
    Nasser, Q. J.
    Stewart, J. A.
    Stewart, W. C.
    EYE, 2009, 23 (01) : 73 - 78
  • [34] A silent interplay between elevated intraocular pressure, glaucoma, and hypertension
    Sato, Tatsuya
    Umetsu, Araya
    Tanaka, Marenao
    Ohguro, Hiroshi
    Furuhashi, Masato
    HYPERTENSION RESEARCH, 2025, 48 (03) : 1208 - 1210
  • [35] Relationship between novel intraocular pressure measurement from Corvis ST and central corneal thickness and corneal hysteresis
    Matsuura, Masato
    Murata, Hiroshi
    Fujino, Yuri
    Yanagisawa, Mieko
    Nakao, Yoshitaka
    Tokumo, Kana
    Nakakura, Shunsuke
    Kiuchi, Yoshiaki
    Asaoka, Ryo
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2020, 104 (04) : 563 - 568
  • [36] Corneal Biomechanical Properties of various types of glaucoma and their impact on measurement of intraocular pressure
    Zhang, Yang
    Bian, Ailing
    Hang, Qijun
    Li, Luee
    Zhang, Shunhua
    Cheng, Gangwei
    Zhou, Qi
    OPHTHALMIC RESEARCH, 2023, 66 (01) : 749 - 756
  • [37] Influence of corneal and other ocular characteristics on measurement of intraocular pressure by three tonometers
    Quigley, HA
    Broman, AT
    Bandeen-Roche, K
    Congdon, NG
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [38] Assessment of the Ocular Response Analyzer as an Instrument for Measurement of Intraocular Pressure and Corneal Biomechanics
    Elsheikh, Ahmed
    Joda, Akram
    Abass, Ahmed
    Garway-Heath, David
    CURRENT EYE RESEARCH, 2015, 40 (11) : 1111 - 1119
  • [39] Differences in Intraocular pressure response to latanoprost between black and white patients with open angle glaucoma and ocular hypertension
    Banks, MC
    Hoffman, D
    Syed, H
    Caprioli, J
    Law, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U1171 - U1171
  • [40] Relationship between corneal hysteresis and intraocular pressure after intraocular volume expansion
    Dackowski, Evan
    Wang, Jessie
    Patel, Sejal
    Panvini, Ana Rubin
    Moon, Jee-Young
    Shrivastava, Anurag
    Schultz, Jeffrey S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)