Relationship between novel intraocular pressure measurement from Corvis ST and central corneal thickness and corneal hysteresis

被引:23
|
作者
Matsuura, Masato [1 ,2 ]
Murata, Hiroshi [1 ]
Fujino, Yuri [1 ]
Yanagisawa, Mieko [1 ]
Nakao, Yoshitaka [3 ]
Tokumo, Kana [3 ]
Nakakura, Shunsuke [4 ]
Kiuchi, Yoshiaki [3 ]
Asaoka, Ryo [1 ]
机构
[1] Univ Tokyo, Dept Ophthalmol, Tokyo 1138655, Japan
[2] Kitasato Univ, Grad Sch Med Sci, Dept Ophthalmol, Sagamihara, Kanagawa, Japan
[3] Hiroshima Univ, Dept Ophthalmol & Visual Sci, Hiroshima, Japan
[4] Saneikai Tsukazaki Hosital, Dept Ophthalmol, Himeji, Hyogo, Japan
基金
日本科学技术振兴机构;
关键词
glaucoma; OCULAR RESPONSE ANALYZER; BIOMECHANICAL PROPERTIES; GOLDMANN APPLANATION; DYNAMIC CONTOUR; TONOMETRY; PROGRESSION; PARAMETERS;
D O I
10.1136/bjophthalmol-2019-314370
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims Corvis ST (CST) yields biomechanical corrected IOP (bIOP) which is purported to be less dependent on biomechanical properties. In our accompanied paper, it was suggested that the repeatability of bIOP is high. The purpose of the current study was to assess the relationship between intraocular pressure (IOP) measured with CST and central corneal thickness (CCT) and corneal hysteresis (CH), in comparison with IOP measured with Goldmann applanation tonometry (GAT) and the ocular response analyzer (ORA). Methods A total of 141 eyes from 141 subjects (35 healthy eyes and 106 glaucomatous eyes) underwent IOP measurements with GAT, CST and ORA. The relationships between IOP measurements (ORA-IOPg, ORA-IOPcc, CST-bIOP and GAT IOP) and biomechanical properties (CCT, CH and corneal resistance factor (CRF)) were analysed using the linear regression analysis. Results IOPg, IOPcc and GAT IOP were significantly associated with CCT (p<0.001), whereas bIOP was not significantly associated with CCT (p=0.19). IOPg, bIOP and GAT IOP were significantly associated with CH (IOPg: p<0.001; bIOP: p<0.001; GAT IOP: p=0.0054), whereas IOPcc was not significantly associated with CH (p=0.18). All of IOP records were associated with CRF (p<0.001). Conclusion The bIOP measurement from CST is independent from CCT, but dependent on CH and CRF.
引用
收藏
页码:563 / 568
页数:6
相关论文
共 50 条
  • [1] The Relationship between Corvis ST Tonometry Measured Corneal Parameters and Intraocular Pressure, Corneal Thickness and Corneal Curvature
    Asaoka, Ryo
    Nakakura, Shunsuke
    Tabuchi, Hitoshi
    Murata, Hiroshi
    Nakao, Yoshitaka
    Ihara, Noriko
    Rimayanti, Ulfah
    Aihara, Makoto
    Kiuchi, Yoshiaki
    [J]. PLOS ONE, 2015, 10 (10):
  • [2] The Relationship between Diurnal Variations in Intraocular Pressure Measurements and Central Corneal Thickness and Corneal Hysteresis
    Kotecha, Aachal
    Crabb, David P.
    Spratt, Alexander
    Garway-Heath, David F.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (09) : 4229 - 4236
  • [3] Relationship between intraocular pressure, central corneal thickness and corneal topography
    Rinaldi, G
    Baccara, F
    Vattovani, O
    Gioulis, D
    Iacono, P
    Cecchini, P
    Ravalico, G
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U967 - U967
  • [4] Agreement in central corneal thickness measurement between Corvis ST and ocular response analyzer
    Salouti, Ramin
    Razeghinejad, Reza
    Masihpour, Nasrin
    Ghoreyshi, Maryam
    Nowroozzadeh, M. Hossein
    [J]. INTERNATIONAL OPHTHALMOLOGY, 2020, 40 (10) : 2563 - 2567
  • [5] Agreement in central corneal thickness measurement between Corvis ST and ocular response analyzer
    Ramin Salouti
    Reza Razeghinejad
    Nasrin Masihpour
    Maryam Ghoreyshi
    M. Hossein Nowroozzadeh
    [J]. International Ophthalmology, 2020, 40 : 2563 - 2567
  • [6] Correlation between corneal hysteresis intraocular pressure, and corneal central pachymetry
    Touboul, David
    Roberts, Cynthia
    Kerautret, Julien
    Garra, Caroline
    Maurice-Tison, Sylvie
    Saubusse, Elodie
    Colin, Joseph
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (04): : 616 - 622
  • [7] Combining corneal hysteresis with central corneal thickness and intraocular pressure for glaucoma risk assessment
    D Pensyl
    M Sullivan-Mee
    M Torres-Monte
    K Halverson
    C Qualls
    [J]. Eye, 2012, 26 : 1349 - 1356
  • [8] Combining corneal hysteresis with central corneal thickness and intraocular pressure for glaucoma risk assessment
    Pensyl, D.
    Sullivan-Mee, M.
    Torres-Monte, M.
    Halverson, K.
    Qualls, C.
    [J]. EYE, 2012, 26 (10) : 1349 - 1356
  • [9] Pachymetry and intraocular pressure measurement by corneal visualization Scheimpflug technology (Corvis ST)
    Steinberg, J.
    Mehlan, J.
    Frings, A.
    Druchkiv, V.
    Richard, G.
    Katz, T.
    Linke, S. J.
    [J]. OPHTHALMOLOGE, 2015, 112 (09): : 770 - 777
  • [10] Corneal hysteresis, central corneal thickness, and intraocular pressure in rheumatoid arthritis, and their relation to disease activity
    Nossair, Ashraf Ahmed
    Kassem, Mona Kassem
    Eltanamly, Rasha Mounir
    Alahmadawy, Yomna Amr
    [J]. MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2021, 28 (03) : 174 - 179