The Relationship between Diurnal Variations in Intraocular Pressure Measurements and Central Corneal Thickness and Corneal Hysteresis

被引:55
|
作者
Kotecha, Aachal [1 ,2 ,3 ,4 ]
Crabb, David P. [3 ]
Spratt, Alexander
Garway-Heath, David F. [1 ,2 ,3 ,4 ]
机构
[1] Moorfields Eye Hosp, Glaucoma Res Unit, London EC1V 2PD, England
[2] UCL Inst Ophthalmol, London, England
[3] City Univ London, Dept Optometry & Visual Sci, London, England
[4] Moorfields Eye Hosp, NIHR, NHS Fdn Trust, Biomed Res Ctr Ophthalmol, London EC1V 2PD, England
关键词
GOLDMANN APPLANATION TONOMETRY; DYNAMIC CONTOUR TONOMETRY; BIOMECHANICAL PROPERTIES; IN-VIVO; GLAUCOMA; AGE; STROMA; EYES; VARIABILITY; EDEMA;
D O I
10.1167/iovs.08-2955
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To examine the relationship between office-hour changes in IOP, measured with the Goldmann applanation tonometer (GAT) and dynamic contour tonometer (DCT), and the corneal characteristics central corneal thickness (CCT) and corneal hysteresis (CH). METHODS. Sixty-two eyes of 62 untreated normal subjects and patients with untreated glaucoma had IOP measurements performed with the GAT (mm Hg) and DCT (mm Hg) over an 8-hour period at 2-hour intervals beginning at 9 AM. CCT (micrometers) was measured using a noncontact optical low-coherence reflectometry (OLCR) pachymeter, and CH (mm Hg) was measured with an ocular response analyzer (ORA). The associations between IOP measurements and corneal characteristics for each patient over the measurement period were assessed by using multilevel modeling. RESULTS. GAT and DCT IOP and CCT changed significantly during office hours (ANOVA; GAT: F = 19.9, P < 0.001; DCT: F = 4.6, P = 0.001; CCT: F = 16.4; P < 0.001). No significant changes were observed in CH (ANOVA; F = 1.8, P = 0.13). Multilevel modeling analysis of the interrelationships between CCT, CH, and age on IOP measurements revealed that both CCT and CH changes were significantly associated with GAT IOP changes (GAT IOP/CCT slope, 0.04 mm Hg/mu m; 95% confidence intervals [CIs], 0.02-0.06; GAT IOP/CH slope, 0.20 mm Hg/mm Hg; 95% CI, 0.01-0.39). CCT, but not CH, changes were significantly associated with DCT IOP changes (DCT IOP/CCT slope, 0.03 mm Hg/mu m; 95% CI, 0.00-0.05). However, although the association between CCT and GAT IOP was relatively uniform between subjects, association between CCT and DCT IOP showed greater intersubject variability. Age had no effect on the diurnal variation of IOP measured with either device. CONCLUSIONS. Measured IOP and corneal characteristics covary during office hours. Changes in CCT and CH are associated with changes in GAT IOP and, less consistently, with DCT IOP. The data suggest that variations in corneal characteristics explain a small proportion of the change in IOP measurements made with the GAT during office hours. (Invest Ophthalmol Vis Sci. 2009;50:4229-4236) DOI: 10.1167/iovs.08-2955
引用
收藏
页码:4229 / 4236
页数:8
相关论文
共 50 条
  • [1] Relationship between intraocular pressure, central corneal thickness and corneal topography
    Rinaldi, G
    Baccara, F
    Vattovani, O
    Gioulis, D
    Iacono, P
    Cecchini, P
    Ravalico, G
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U967 - U967
  • [2] Diurnal variations in intraocular pressure and central corneal thickness and the correlation between these factors in dogs
    Garzon-Ariza, Alicia
    Guisado, Alicia
    Galan, Alba
    Martin-Suarez, Eva
    [J]. VETERINARY OPHTHALMOLOGY, 2018, 21 (05) : 464 - 470
  • [3] Relationship between novel intraocular pressure measurement from Corvis ST and central corneal thickness and corneal hysteresis
    Matsuura, Masato
    Murata, Hiroshi
    Fujino, Yuri
    Yanagisawa, Mieko
    Nakao, Yoshitaka
    Tokumo, Kana
    Nakakura, Shunsuke
    Kiuchi, Yoshiaki
    Asaoka, Ryo
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2020, 104 (04) : 563 - 568
  • [4] Diurnal Variation of Ocular Hysteresis, Corneal Thickness, and Intraocular Pressure
    Shen, Meixiao
    Wang, Jianhua
    Qu, Jia
    Xu, Suzhong
    Wang, Xiaoxing
    Fang, Haizhen
    Lu, Fan
    [J]. OPTOMETRY AND VISION SCIENCE, 2008, 85 (12) : 1185 - 1192
  • [5] Relationship between Diurnal Variation in Intraocular Pressure and Central Corneal Power
    Biswas, Sayantan
    Biswas, Partha
    [J]. OPTOMETRY AND VISION SCIENCE, 2023, 100 (01) : 96 - 104
  • [6] Correlation between corneal hysteresis intraocular pressure, and corneal central pachymetry
    Touboul, David
    Roberts, Cynthia
    Kerautret, Julien
    Garra, Caroline
    Maurice-Tison, Sylvie
    Saubusse, Elodie
    Colin, Joseph
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (04): : 616 - 622
  • [7] Combining corneal hysteresis with central corneal thickness and intraocular pressure for glaucoma risk assessment
    D Pensyl
    M Sullivan-Mee
    M Torres-Monte
    K Halverson
    C Qualls
    [J]. Eye, 2012, 26 : 1349 - 1356
  • [8] Combining corneal hysteresis with central corneal thickness and intraocular pressure for glaucoma risk assessment
    Pensyl, D.
    Sullivan-Mee, M.
    Torres-Monte, M.
    Halverson, K.
    Qualls, C.
    [J]. EYE, 2012, 26 (10) : 1349 - 1356
  • [9] Diurnal variation of central corneal thickness and intraocular pressure in eyes with pseudoexfoliation
    Syed, Zeeshan
    Srikanth, Krishnagopal
    Nagarajan, Swathi
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (10) : 1607 - 1609
  • [10] Corneal hysteresis, central corneal thickness, and intraocular pressure in rheumatoid arthritis, and their relation to disease activity
    Nossair, Ashraf Ahmed
    Kassem, Mona Kassem
    Eltanamly, Rasha Mounir
    Alahmadawy, Yomna Amr
    [J]. MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2021, 28 (03) : 174 - 179