Effect of Different Implant Designs on Strain and Stress Distribution under Non-Axial Loading: A Three-Dimensional Finite Element Analysis

被引:27
|
作者
Oliveira, Helder [1 ]
Velasco, Aritza Brizuela [2 ]
Rios-Santos, Jose-Vicente [3 ]
Lasheras, Fernando Sanchez [4 ]
Lemos, Bernardo Ferreira [1 ]
Gil, Francisco Javier [5 ]
Carvalho, Alexandrine [1 ]
Herrero-Climent, Mariano [6 ]
机构
[1] Univ Fernando Pessoa, Fac Hlth Sci, P-4200150 Porto, Portugal
[2] Univ Oviedo, Dept Surg & Med Surg Specialties, Oviedo 33006, Spain
[3] Univ Seville, Sch Dent, Dept Periodontol, Seville 41009, Spain
[4] Univ Oviedo, Fac Sci, Math Dept, Oviedo 33007, Spain
[5] Univ Int Catalunya, Bioengn Inst Technol, Barcelona 08017, Spain
[6] Porto Dent Inst, P-4150518 Oporto, Portugal
关键词
dental implants; design; finite element analysis; strain distribution; stress distribution; bone quality; CONTROLLED CLINICAL-TRIAL; DENTAL IMPLANTS; OSSEOINTEGRATED IMPLANTS; EDENTULOUS PATIENTS; PRIMARY STABILITY; BONE-RESORPTION; EXTRACTION; IMMEDIATE; MICROMOTION; INTERFACE;
D O I
10.3390/ijerph17134738
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Implant design evolved alongside the development of implant therapy. The purpose of this finite element analysis (FEA) study was to analyze the influence of different implant designs on the stress and strain distribution to the implants and surrounding bone. Three implant designs with the same length and diameter were used. The three-dimensional geometry of the bone was simulated with a cortical bone of three different thicknesses and two medullar bone densities: low density (150 Hounsfield units) and high density (850 Hounsfield units). A 30 degrees oblique load of 150 N was applied to the implant restoration. Displacement and stress (von Mises) results were obtained for bone and dental implants. The strain and stress distributions to the bone were higher for the tissue-level implant for all types of bone. The maximum principal strain and stress decreased with an increase in cortical bone thickness for both cancellous bone densities. The distribution of the load was concentrated at the coronal portion of the bone and implants. All implants showed a good distribution of forces for non-axial loads, with higher forces concentrated at the crestal region of the bone-implant interface. Decrease in medullar bone density negatively affects the strain and stress produced by the implants.
引用
收藏
页码:1 / 17
页数:17
相关论文
共 50 条
  • [21] Finite element analysis of non-axial versus axial loading of oral implants in the mandible of the dog
    Barbier, L
    Vander Sloten, J
    Krzesinski, G
    Schepers, E
    Van Der Perre, G
    JOURNAL OF ORAL REHABILITATION, 1998, 25 (11) : 847 - 858
  • [22] Three-dimensional finite element analysis of three removable partial dentures under different loading conditions
    Cui, Wen
    Wang, Dong-Mei
    Wang, Cheng-Tao
    Huang, Qing-Feng
    Zhang, Fu-Qiang
    Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University, 2010, 44 (11): : 1588 - 1594
  • [23] Three-dimensional finite element analysis of stress distribution in different type of fixture applications
    Fioratti, R
    Guida, A
    Lupoli, G
    Eramo, S
    Giuca, MR
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 552 - 552
  • [24] Analysis of the Effect of Thread Depth in Four Different Thread Designs on the Stress Distribution at the Implant-bone Interface Using Finite Element Analysis - A Comparative Three-Dimensional In vitro Study
    Patwari, Swati
    Sahu, Jeeban
    Samanta, Satyaki
    Bharti, Shreya
    Saha, Dipanwita
    Manna, Rohan
    JOURNAL OF THE INTERNATIONAL CLINICAL DENTAL RESEARCH ORGANIZATION, 2024, 16 (01) : 48 - 54
  • [25] Finite Element Analysis of the Stress Distribution Associated With Different Implant Designs for Different Bone Densities
    Kurtulus, Ikbal Leblebicioglu
    Kilic, Kerem
    Bal, Burak
    Kilavuz, Ahmet
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (07): : 614 - 622
  • [26] A Three-dimensional Finite Element Analysis of Effect of Abutment Materials on Stress Distribution around Peri-Implant Bone in Immediate and Delayed Loading Conditions
    AGARWAL, S. A. U. M. Y. A.
    TRIVEDI, A. N. S. H. U. L.
    KUSUM, C. H. A. N. D. A. N. K.
    GOSWAM, R. O. M. A., I
    MOWAR, A. P. O. O. R. V. A.
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2022, 16 (06) : ZC55 - ZC60
  • [27] Comparative Evaluation of Implant Designs: Influence of Diameter, Length, and Taper on Stress and Strain in the Mandibular Segment-A Three-Dimensional Finite Element Analysis
    Raaj, Gowthama
    Manimaran, Pulliappan
    Kumar, Chandran Dhinesh
    Sadan, Duraisamy Sai
    Abirami, Mathivanan
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2019, 11 : S347 - S354
  • [28] Three-Dimensional Finite Element Analysis on Stress Distribution of Internal Implant-Abutment Engagement Features
    Cho, Sung-Yong
    Huh, Yun-Hyuk
    Park, Chan-Jin
    Cho, Lee-Ra
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (02) : 319 - 327
  • [29] Three-dimensional finite element stress analysis of a cuneiform-geometry implant
    Cruz, M
    Wassall, T
    Toledo, EM
    Barra, LPD
    Lemonge, ACD
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2003, 18 (05) : 675 - 684
  • [30] Stress Analysis of Dental Implant Bodies by Three-Dimensional Finite Element Method
    Kageyama, Yoshiyuki
    Shimura, Mari
    Nagai, Eiichi
    Sato, Yoshinori
    Majima, Hideyuki
    Journal of Robotics and Mechatronics, 1995, 7 (02): : 169 - 171