Functional phantom for fMRI: a feasibility study

被引:12
|
作者
Renvall, V
Joensuu, R
Hari, R
机构
[1] Helsinki Univ Technol, Adv Magnet Imaging Ctr, FI-02015 TKK Espoo, Finland
[2] Helsinki Univ Technol, Low Temp Lab, Brain Res Unit, FI-02015 TKK Espoo, Finland
基金
芬兰科学院;
关键词
fMRI; BOLD; simulation; phantom; calibration;
D O I
10.1016/j.mri.2005.07.012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Functional magnetic resonance imaging (fMRI) reveals changes in blood oxygen level-dependent (BOLD) signal after considerable processing. This paper describes the implementation and testing of an fMRI phantom where electric current applied to a thin wire within a proton-rich medium substituted BOLD distortion of the magnetic field; the scanner detects these two distortions as practically identical signal changes. The magnitude of the change depended on the current strength. The phantom has a number of possible applications. Signal changes across sessions, days, instruments and individuals could be monitored. Placing the phantom close to a subject during an fMRI experiment could allow differentiating sensitivity changes in the scanner due to instrumentation from changes in the subject's state and performance during the experiment. The spatial extent of brain activations and effects of various changes in the chain of image formation could be analyzed using current-induced "activations". Furthermore, the phantom could expedite fMRI sequence development by reducing the need to scan human subjects, who introduce uncertainty to the signal. Thus, this fMRI phantom could be useful for both cognitive fMRI studies and scanner calibration. (C) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:315 / 320
页数:6
相关论文
共 50 条
  • [41] The functional anatomy of inspection time: a pilot fMRI study
    Deary, IJ
    Simonotto, E
    Marshall, A
    Marshall, I
    Goddard, N
    Wardlaw, JM
    INTELLIGENCE, 2001, 29 (06) : 497 - 510
  • [42] The functional anatomy of moral judgment - an fMRI-Study
    Heekeren, HR
    Wartenburger, I
    Schmidt, H
    Denkler, C
    Schwintowski, H
    Villringer, A
    NEUROIMAGE, 2001, 13 (06) : S417 - S417
  • [43] A functional MRI (fMRI) study of the perception of humor.
    Desmond, JE
    Cronin-Golomb, A
    Gabrieli, JDE
    Glover, GH
    JOURNAL OF COGNITIVE NEUROSCIENCE, 1998, 10 : 104 - 104
  • [44] A Rotational Cylindrical fMRI Phantom for Image Quality Control
    Tovar, David A.
    Zhan, Wang
    Rajan, Sunder S.
    PLOS ONE, 2015, 10 (12):
  • [45] Low Field NMR as a Tool for Neuronal Current Detection: A Feasibility Study in a Phantom
    Koerber, Rainer
    Hoefner, Nora
    Burghoff, Martin
    Trahms, Lutz
    Haueisen, Jens
    Martens, Sven
    Curio, Gabriel
    MAGNETIC PARTICLE IMAGING: A NOVEL SPIO NANOPARTICLE IMAGING TECHNIQUE, 1ST EDITION, 2012, 140 : 369 - 370
  • [46] Feasibility study of automating breast phantom scoring using image processing techniques
    Adel, I
    Guis, VH
    Rasigni, M
    Bourennane, S
    Image Processing: Algorithms and Systems IV, 2005, 5672 : 201 - 211
  • [47] Design and Use of a Custom Phantom for Regular Tests of Radiography Apparatus: A Feasibility Study
    Dukov, Nikolay
    Valkova, Vanessa-Mery
    Yordanova, Mariana
    Tsapaki, Virginia
    Bliznakova, Kristina
    JOURNAL OF IMAGING, 2024, 10 (10)
  • [48] Feasibility study to establish polymer gel dosimetry in a real lung tissue phantom
    Moser, T.
    Armbruster, S.
    Runz, A.
    Biederer, J.
    Karger, C. P.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S143 - S144
  • [49] Feasibility Study on Microwave Stroke Detection using a Realistic Phantom and the FDTD Method
    Ireland, David
    Bialkowski, Marek
    2010 ASIA-PACIFIC MICROWAVE CONFERENCE, 2010, : 1360 - 1363
  • [50] A feasibility study of magnetic resonance driven electrical impedance tomography using a phantom
    Wan, Yuqing
    Negishi, Michiro
    Constable, R. Todd
    PHYSIOLOGICAL MEASUREMENT, 2013, 34 (06) : 623 - 644