Functional phantom for fMRI: a feasibility study

被引:12
|
作者
Renvall, V
Joensuu, R
Hari, R
机构
[1] Helsinki Univ Technol, Adv Magnet Imaging Ctr, FI-02015 TKK Espoo, Finland
[2] Helsinki Univ Technol, Low Temp Lab, Brain Res Unit, FI-02015 TKK Espoo, Finland
基金
芬兰科学院;
关键词
fMRI; BOLD; simulation; phantom; calibration;
D O I
10.1016/j.mri.2005.07.012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Functional magnetic resonance imaging (fMRI) reveals changes in blood oxygen level-dependent (BOLD) signal after considerable processing. This paper describes the implementation and testing of an fMRI phantom where electric current applied to a thin wire within a proton-rich medium substituted BOLD distortion of the magnetic field; the scanner detects these two distortions as practically identical signal changes. The magnitude of the change depended on the current strength. The phantom has a number of possible applications. Signal changes across sessions, days, instruments and individuals could be monitored. Placing the phantom close to a subject during an fMRI experiment could allow differentiating sensitivity changes in the scanner due to instrumentation from changes in the subject's state and performance during the experiment. The spatial extent of brain activations and effects of various changes in the chain of image formation could be analyzed using current-induced "activations". Furthermore, the phantom could expedite fMRI sequence development by reducing the need to scan human subjects, who introduce uncertainty to the signal. Thus, this fMRI phantom could be useful for both cognitive fMRI studies and scanner calibration. (C) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:315 / 320
页数:6
相关论文
共 50 条
  • [21] Feasibility of using fMRI to study mothers responding to infant cries
    Lorberbaum, JP
    Newman, JD
    Dubno, JR
    Horwitz, AR
    Nahas, Z
    Teneback, CC
    Bloomer, CW
    Bohning, DE
    Vincent, D
    Johnson, MR
    Emmanuel, N
    Brawman-Mintzer, O
    Book, SW
    Lydiard, RB
    Ballenger, JC
    George, MS
    DEPRESSION AND ANXIETY, 1999, 10 (03) : 99 - 104
  • [22] Assessment of Surgical Skills Competence Using fMRI: A Feasibility Study
    Morris, M. C.
    Frodl, T.
    D'Souza, A.
    Fagan, A. J.
    Ridgway, P. F.
    BRITISH JOURNAL OF SURGERY, 2015, 102 : 199 - 199
  • [23] Phantom haptic device upgrade for use in fMRI
    Hribar, Ales
    Koritnik, Blaz
    Munih, Marko
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2009, 47 (06) : 677 - 684
  • [24] Phantom haptic device upgrade for use in fMRI
    Ales Hribar
    Blaz Koritnik
    Marko Munih
    Medical & Biological Engineering & Computing, 2009, 47 : 677 - 684
  • [25] Accuracy and Feasibility of Synthetic CT for Lung Adaptive Radiotherapy: A Phantom Study
    Zhao, Ruifeng
    Wang, Xingliu
    Wei, Huanhai
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2023, 22
  • [26] Accuracy and Feasibility of Synthetic CT for Lung Adaptive Radiotherapy: A Phantom Study
    Zhao, Ruifeng
    Wang, Xingliu
    Wei, Huanhai
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2023, 22
  • [27] Compressed Sensing for fMRI: Feasibility Study on the Acceleration of Non-EPI fMRI at 9.4T
    Han, Paul Kyu
    Park, Sung-Hong
    Kim, Seong-Gi
    Ye, Jong Chul
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [28] A phantom feasibility study of acoustic enhanced drug perfusion in neurological tissue
    Lewis, George K., Jr.
    Olbricht, William
    2007 IEEE/NIH LIFE SCIENCE SYSTEMS AND APPLICATIONS WORKSHOP, 2007, : 67 - +
  • [29] Biplane Correlation Imaging: A Feasibility Study Based on Phantom and Human Data
    Samei, Ehsan
    Majdi-Nasab, Nariman
    Dobbins, James T., III
    McAdams, H. Page
    JOURNAL OF DIGITAL IMAGING, 2012, 25 (01) : 137 - 147
  • [30] Measurement of CT Dose to An HDPE Phantom Using Calorimetry: A Feasibility Study
    Chen-Mayer, H.
    Tosh, R.
    Bateman, F.
    Zimmerman, B.
    MEDICAL PHYSICS, 2012, 39 (06) : 3635 - 3635