Microwave-assisted solid phase extraction prior to ICP-MS determination of Pd and Pt in environmental and biological samples

被引:6
|
作者
Kovachev, N. [1 ,2 ]
Sanchez, A. [3 ]
Simitchiev, K. [4 ]
Stefanova, V. [4 ]
Kmetov, V. [4 ]
Canals, A. [1 ,2 ]
机构
[1] Univ Alicante, Dept Quim Analit Nutr & Bromatol, E-03080 Alicante, Spain
[2] Univ Alicante, Inst Univ Mat, E-03080 Alicante, Spain
[3] Ctr Salud Publ, Lab Salud Publ Alicante, Alicante, Spain
[4] Paisij Hilendarski Univ Plovdiv, Dept Analyt Chem, BG-4000 Plovdiv, Bulgaria
关键词
microwave-assisted solid phase extraction; ICP-MS; palladium determination; platinum determination; environmental samples; biological samples; PLATINUM-GROUP ELEMENTS; ATOMIC-ABSORPTION-SPECTROMETRY; PLASMA-MASS SPECTROMETRY; AIRBORNE PARTICULATE MATTER; ONLINE PRECONCENTRATION; ROAD DUST; SILICA-GEL; CATALYTIC-CONVERTERS; ANALYTICAL-CHEMISTRY; GROUP METALS;
D O I
10.1080/03067319.2010.534158
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and selective microwave-assisted solid phase extraction procedure coupled to inductively coupled plasma-mass spectrometry (ICP-MS) is proposed for palladium (Pd) and platinum (Pt) quantification in environmental and biological samples. Pd and Pt were quantitatively retained on commercial thioureido propyl functionalised silica gel packed inside a home-made glass microcolumn, and later eluted with 0.5% thiourea solution under microwave irradiation, followed by ICP-MS determination. The main variables affecting the procedural stages (i.e., sorption and desorption) and ICP-MS determination were optimised. The best conditions found were: (a) sorption: sample acidity, 1 M HCl; sample flow rate, 3 mL min(-1); (b) desorption: microwave radiation, power 800 W; eluent concentration, 0.5% thiourea; eluent flow rate, 0.5 mL min(-1); (c) ICP-MS determination: nebuliser feeding, free aspiration (0.3 mL min(-1)); internal standard, Rh (5 mg L-1). Analyte recoveries were higher than 90% and concentration factors up to 90 and 92 were achieved for Pd and Pt, respectively. Depending on the conditions, the methodological limits of detection were down to 0.2 ng L-1 for both analytes and repeatability, expressed as RSD%, varied between 1.3 and 11.0%. A method selectivity evaluation showed that most of the ICP-MS interferents were either quantitatively separated or more than 86% eliminated, except for Cu (elimination efficiency around 30%). Finally, the method was successfully used to determine Pd in certified reference materials (i.e. human urine and serum) and Pd and Pt in PM10 airborne particulate matter fractions.
引用
收藏
页码:1106 / 1119
页数:14
相关论文
共 50 条
  • [31] Simple, fast, and low-contamination microwave-assisted digestion procedures for the determination of chemical elements in biological and environmental matrices by sector field ICP-MS
    Bocca, Beatrice
    Conti, Marcelo Enrique
    Pino, Anna
    Mattei, Daniela
    Forte, Giovanni
    Alimonti, Alessandro
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2007, 87 (15) : 1111 - 1123
  • [32] Semiautomatic method for the ultra-trace arsenic speciation in environmental and biological samples via magnetic solid phase extraction prior to HPLC-ICP-MS determination
    Montoro-Leal, P.
    Garcia-Mesa, J. C.
    Morales-Benitez, I
    Garcia de Torres, A.
    Vereda Alonso, E.
    TALANTA, 2021, 235 (235)
  • [33] Preconcentration and Determination of Trace Cu, Pb, and Zn in Biological Samples by Combining Carbon Nanofibers (CNFs) as a Solid Phase Extraction Adsorbent with ICP-MS
    He, Yuanyuan
    Chen, Shizhong
    Zhou, Xiaorong
    Wang, Xing
    ATOMIC SPECTROSCOPY, 2012, 33 (04) : 117 - 122
  • [34] Determination of U isotopic ratios in environmental samples by ICP-MS
    Uchida, S
    García-Tenorio, R
    Tagami, K
    García-León, M
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (07) : 889 - 892
  • [35] Multi-element determination of Pt, Pd and Ir traces in environmental samples by ICP-MS after pre-concentration
    Alonso Castillo, Manuel L.
    Garcia de Torres, Amparo
    Vereda Alonso, Elisa
    Siles Cordero, Ma Teresa
    Cano Pavon, Jose Manuel
    TALANTA, 2012, 99 : 853 - 858
  • [36] Determination of stable lead isotope ratios in environmental samples: Combination of microwave digestion and ICP-MS
    H. Kawamura
    H. Tagomori
    N. Matsuoka
    Y. Takashima
    S. Tawaki
    N. Momoshima
    Journal of Radioanalytical and Nuclear Chemistry, 1999, 242 : 717 - 720
  • [37] Determination of stable lead isotope ratios in environmental samples: Combination of microwave digestion and ICP-MS
    Kawamura, H
    Tagomori, H
    Matsuoka, N
    Takashima, Y
    Tawaki, S
    Momoshima, N
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1999, 242 (03) : 717 - 720
  • [38] Development of an automatic pH-adjustment system for solid phase extraction prior to the determination of REEs in seawater by ICP-MS
    Zhu, Yanbei
    Hioki, Akiharu
    Chiba, Koichi
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (06) : 883 - 889
  • [39] Microwave-assisted micellar extraction coupled with solid-phase extraction for preconcentration of pharmaceuticals in molluscs prior to determination by HPLC
    Cueva-Mestanza, R.
    Torres-Padron, M. E.
    Sosa-Ferrera, Z.
    Santana-Rodriguez, J. J.
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (10) : 1115 - 1122
  • [40] Automation of 99Tc extraction by LOV prior ICP-MS detection: Application to environmental samples
    Rodriguez, Rogelio
    Leal, Luz
    Miranda, Silvia
    Ferrer, Laura
    Avivar, Jessica
    Garcia, Ariel
    Cerda, Victor