Microwave-assisted solid phase extraction prior to ICP-MS determination of Pd and Pt in environmental and biological samples

被引:6
|
作者
Kovachev, N. [1 ,2 ]
Sanchez, A. [3 ]
Simitchiev, K. [4 ]
Stefanova, V. [4 ]
Kmetov, V. [4 ]
Canals, A. [1 ,2 ]
机构
[1] Univ Alicante, Dept Quim Analit Nutr & Bromatol, E-03080 Alicante, Spain
[2] Univ Alicante, Inst Univ Mat, E-03080 Alicante, Spain
[3] Ctr Salud Publ, Lab Salud Publ Alicante, Alicante, Spain
[4] Paisij Hilendarski Univ Plovdiv, Dept Analyt Chem, BG-4000 Plovdiv, Bulgaria
关键词
microwave-assisted solid phase extraction; ICP-MS; palladium determination; platinum determination; environmental samples; biological samples; PLATINUM-GROUP ELEMENTS; ATOMIC-ABSORPTION-SPECTROMETRY; PLASMA-MASS SPECTROMETRY; AIRBORNE PARTICULATE MATTER; ONLINE PRECONCENTRATION; ROAD DUST; SILICA-GEL; CATALYTIC-CONVERTERS; ANALYTICAL-CHEMISTRY; GROUP METALS;
D O I
10.1080/03067319.2010.534158
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and selective microwave-assisted solid phase extraction procedure coupled to inductively coupled plasma-mass spectrometry (ICP-MS) is proposed for palladium (Pd) and platinum (Pt) quantification in environmental and biological samples. Pd and Pt were quantitatively retained on commercial thioureido propyl functionalised silica gel packed inside a home-made glass microcolumn, and later eluted with 0.5% thiourea solution under microwave irradiation, followed by ICP-MS determination. The main variables affecting the procedural stages (i.e., sorption and desorption) and ICP-MS determination were optimised. The best conditions found were: (a) sorption: sample acidity, 1 M HCl; sample flow rate, 3 mL min(-1); (b) desorption: microwave radiation, power 800 W; eluent concentration, 0.5% thiourea; eluent flow rate, 0.5 mL min(-1); (c) ICP-MS determination: nebuliser feeding, free aspiration (0.3 mL min(-1)); internal standard, Rh (5 mg L-1). Analyte recoveries were higher than 90% and concentration factors up to 90 and 92 were achieved for Pd and Pt, respectively. Depending on the conditions, the methodological limits of detection were down to 0.2 ng L-1 for both analytes and repeatability, expressed as RSD%, varied between 1.3 and 11.0%. A method selectivity evaluation showed that most of the ICP-MS interferents were either quantitatively separated or more than 86% eliminated, except for Cu (elimination efficiency around 30%). Finally, the method was successfully used to determine Pd in certified reference materials (i.e. human urine and serum) and Pd and Pt in PM10 airborne particulate matter fractions.
引用
收藏
页码:1106 / 1119
页数:14
相关论文
共 50 条
  • [21] Microwave-assisted micro-solid-phase extraction for analysis of tetracycline antibiotics in environmental samples
    Jiao, Zhe
    Guo, Zongning
    Zhang, Suling
    Chen, Hongwei
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2015, 95 (01) : 82 - 91
  • [22] Microwave-assisted solvent extraction of environmental samples
    Camel, V
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2000, 19 (04) : 229 - 248
  • [23] Microwave-assisted extraction: Application to the determination of emerging pollutants in solid samples
    Sanchez-Prado, Lucia
    Garcia-Jares, Carmen
    Llompart, Maria
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (16) : 2390 - 2414
  • [24] Microwave-assisted vapor phase dissolution of photoresist and silicon oxide based slurry samples for the determination of trace impurities by high resolution ICP-MS
    Wan, CC
    Jiang, SJ
    You, MT
    Sahayam, AC
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2005, 20 (11) : 1290 - 1292
  • [25] Microwave-assisted vapor phase dissolution of photoresist and silicon oxide based slurry samples for the determination of trace impurities by high resolution ICP-MS
    Wan, Chia-Ching
    Jiang, Shiuh-Jen
    You, Min-Ta
    Sahayam, A.C.
    Journal of Analytical Atomic Spectrometry, 2005, 20 (11): : 1290 - 1292
  • [26] Microwave-assisted extraction for further Cl, Br, and I determination in medicinal plants by ICP-MS: a study of carbon interferences
    Nascimento, Mariele S.
    Druzian, Gabriel T.
    Pereira, Leticia S. F.
    Mesko, Marcia F.
    Picoloto, Rochele S.
    Mello, Paola A.
    Flores, Erico M. M.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (03) : 535 - 543
  • [27] Determination of polychlorinated biphenyls and chlorinated pesticides in environmental biological samples using focused microwave-assisted extraction
    Thompson, S
    Budzinski, H
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2000, 76 (01) : 49 - 60
  • [28] Speciation Analysis of Chromium in Water Samples With Pretreated Orange Peel "Solid Phase Extraction and Determination by ICP-MS
    Cheng, Xianzhong
    Peng, Yuan
    Cheng, Kuang
    Song, Yuyao
    Zhang, Shunxi
    ATOMIC SPECTROSCOPY, 2013, 34 (06) : 199 - 206
  • [29] Determination of Mineral Elements in Eight Pear Varieties by ICP-MS after Microwave-Assisted Digestion
    Chen Ji-luan
    Wu Ji-hong
    Jiang Ying
    Hu Xiao-song
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29 (02) : 496 - 498
  • [30] Preparation of Food Samples Using Homogenization and Microwave-Assisted Wet Acid Digestion for Multi-Element Determination with ICP-MS
    Rantasa, Matjaz
    Majer, David
    Finsgar, Matjaz
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2023, (202):