A Practical Fault Phase Selection Scheme for Untransposed Double-circuit Transmission Lines on the Same Tower

被引:0
|
作者
Zhang, Shifeng
Hao, Zhiguo
Chao, Guang
Huang, Mingyu
Bo, Zhiqian
机构
关键词
Asymmetry; Double-circuit transmission lines; Fault phase selection; Six-sequence component;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Double-circuit transmission lines are usually untransposed within short distance, in which case the fault characteristics will be significantly different from the ideal transposition cases. In this paper, based on the analysis of fault characteristics of the untransposed double-circuit transmission lines on the same tower, a practical fault phase selection scheme is proposed to identify various fault types. Firstly, on the base of six-sequence component, the voltage, current and phase angle information are used to classify the faults into single line faults, same phase cross-county faults and different phase cross-county faults. Then, for each of the three categories, the specific fault phase is selected according to the current phase information. The simulation results of PSCAD given in this paper illustrate that the scheme proposed can withstand a greater degree of asymmetry of lines and identify all the fault types accurately.
引用
收藏
页码:788 / 793
页数:6
相关论文
共 50 条
  • [41] Optimal trip schemes of double-circuit lines on the same tower for crossing-line faults
    Qi, Liang
    Li, Yongli
    Li, Botong
    Su, Bin
    Jing, Lei
    Wang, Dechang
    [J]. 2008, Automation of Electric Power Systems Press (32):
  • [42] LIGHTNING PERFORMANCE OF DOUBLE-CIRCUIT TRANSMISSION LINES
    SARGENT, MA
    DARVENIZ.M
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1970, PA89 (05): : 913 - &
  • [43] Online parameter measurement of double-circuit transmission lines based on fault recorder
    Wei, Heng
    Zhou, Di
    Wang, Yi
    [J]. Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2011, 39 (23): : 138 - 142
  • [44] CALCULATION OF MATRICES CHARACTERIZING DOUBLE-CIRCUIT 3 PHASE TRANSMISSION LINES
    VAGO, I
    [J]. PERIODICA POLYTECHNICA-ELECTRICAL ENGINEERING, 1971, 15 (04): : 391 - &
  • [46] Unsynchronized Parameter-Free Fault Location for Two or Three Terminal Double-Circuit Transmission Lines Sharing the Same Tower via Unscented Kalman Filter
    Wang, Binglin
    Liu, Yu
    Lu, Dian
    Yue, Kang
    Nie, Yuan
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2023, 38 (03) : 1731 - 1746
  • [47] Reliability Evaluation and Weak Component Identification of ±500-kV HVDC Transmission Systems With Double-Circuit Lines on the Same Tower
    Hu, Bo
    Xie, Kaigui
    Tai, Heng-Ming
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (04) : 1716 - 1726
  • [48] Fault location on double-circuit transmission lines by phase correction of fault recorder signals without accurate time synchronization
    Peng, Nan
    Zhou, Lutian
    Liang, Rui
    Xue, Xue
    Piliposyan, Gor
    Hu, Yihua
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2020, 181
  • [49] Analysis of Long-term Measured Data of Audible Noise on UHV AC Double-circuit Transmission Lines on the Same Tower
    Zhang Y.
    Li R.
    Zhou B.
    Liu Z.
    He W.
    Li B.
    [J]. Gaodianya Jishu/High Voltage Engineering, 2017, 43 (07): : 2301 - 2308
  • [50] Novel scheme of fault phase selection for mixed-voltage four-circuit lines on same tower based on waveform correlation
    Zheng T.
    Yu S.
    Wu J.
    Luo M.
    [J]. Zheng, Tao (zhengtao_sf@126.com), 1600, Electric Power Automation Equipment Press (40): : 138 - 143and149