Vibration problem solution of high-capacity hydropower units

被引:1
|
作者
Khalyasmaa, A. I. [1 ]
Sultonov, S. M. [2 ]
Ahyoev, J. S. [2 ]
Bahovadinov, A. H. [3 ]
机构
[1] Ural Fed Univ, Ekaterinburg, Russia
[2] Tajik Tech Univ, Dept Power Stat, Dushanbe, Tajikistan
[3] Sangtuda 2 HPP, Engn & Maintenance Dept, Dushanbe, Tajikistan
关键词
D O I
10.1088/1757-899X/836/1/012009
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper proposes hydro generator vibration observations under various conditions and solution of a problem of high vibration in upper guide bearing of 110MW hydro generator. Among the test, which were carried out to identify vibration origin of hydro generating unit were: voltage drop tests, magnetic flux measurements, interferric gap measurements, turbine pressure pulsation measurements, etc. It was shown, that among other possible reasons, correct balancing, including pivot bearing adjustment was the most efficient measure to eliminate vibration in start-up modes of hydro power unit. According to the results of conducted step-by-step defect analysis, the corresponding recommendations were provided for service and maintenance regarding the generation unit No2 of Sangtuda-2 Hydro Power Plant, Tajikistan.
引用
收藏
页数:5
相关论文
共 50 条
  • [42] Investigation of Annular Furnaces and Development of a Boiler Profile for High-capacity Power Units.
    Serant, F.A.
    Zmeikov, V.N.
    Ustimenko, B.P.
    Tochilkin, V.N.
    Strizhko, Yu.V.
    Bulgakov, V.V.
    Ivanov, V.B.
    Kharkin, Yu.A.
    Itman, D.L.
    Svyatov, V.A.
    Teploenergetika, 1982, (10): : 33 - 36
  • [43] Concept and performance testing of a high-capacity oil damper comprising multiple damper units
    Yamamoto, Masashi
    Minewaki, Shigeo
    Nakahara, Manabu
    Tsuyuki, Yasuo
    Earthquake Engineering and Structural Dynamics, 2016, 45 (12): : 1919 - 1933
  • [44] Concept and performance testing of a high-capacity oil damper comprising multiple damper units
    Yamamoto, Masashi
    Minewaki, Shigeo
    Nakahara, Manabu
    Tsuyuki, Yasuo
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2016, 45 (12): : 1919 - 1933
  • [45] RAISING FLEXIBILITY AND RELIABILITY OF ONCE-THROUGH BOILERS OF HIGH-CAPACITY POWER UNITS
    PISKAREV, AA
    SERGEEV, VF
    THERMAL ENGINEERING, 1971, 18 (08) : 64 - &
  • [47] SCOPE FOR INCREASING SERVICE LIFE OF METAL IN HIGH-TEMPERATURE ELEMENTS OF HIGH-CAPACITY GENERATING UNITS
    ZOREV, NN
    KRYANIN, NR
    TRUSOV, LP
    THERMAL ENGINEERING, 1976, 23 (10) : 1 - 5
  • [48] Experience with Construction of High-pressure Centrifugal Fans for High-capacity Power Plant Units.
    Semov, V.V.
    Levinson, T.D.
    Lyamin, A.G.
    Energomashinostroenie, 1981, (07): : 8 - 11
  • [49] HIGH-CAPACITY STRIP SEALER
    不详
    VERPACKUNGS RUNDSCHAU, 1978, 29 (10): : 1530 - 1530
  • [50] Weavable high-capacity electrodes
    Sun, Chuan-Fu
    Zhu, Hongli
    Baker, Edward B., III
    Okada, Morihiro
    Wan, Jiayu
    Ghemes, Adrian
    Inoue, Yoku
    Hu, Liangbing
    Wang, YuHuang
    NANO ENERGY, 2013, 2 (05) : 987 - 994