IMAGING LUNG AERATION AND LUNG LIQUID CLEARANCE AT BIRTH USING PHASE CONTRAST X-RAY IMAGING

被引:58
|
作者
Hooper, Stuart B. [1 ]
Kitchen, Marcus J. [3 ]
Siew, Melissa L. L. [1 ]
Lewis, Robert A. [3 ,4 ]
Fouras, Andreas [5 ]
Pas, Arjan B. Te [6 ]
Siu, Karen K. W. [3 ,4 ]
Yagi, Naoto [2 ]
Uesugi, Kentaro [2 ]
Wallace, Megan J. [1 ]
机构
[1] Monash Univ, Dept Physiol, Clayton, Vic 3800, Australia
[2] SPring 8 JASRI, Sayo, Hyogo, Japan
[3] Monash Univ, Sch Phys, Clayton, Vic 3800, Australia
[4] Monash Univ, Monash Ctr Synchrotron Sci, Clayton, Vic 3800, Australia
[5] Monash Univ, Dept Biol Engn, Clayton, Vic 3800, Australia
[6] Royal Hosp Women, Div Newborn Serv, Melbourne, Vic, Australia
关键词
birth; fetus; lung aeration; mechanical ventilation; preterm birth; spontaneous breathing at birth; END-EXPIRATORY PRESSURE; FUNCTIONAL RESIDUAL CAPACITY; FETAL LUNG; VENTILATION; PRETERM; AIR; STRATEGIES; SECRETION; EXPANSION; SPECKLE;
D O I
10.1111/j.1440-1681.2008.05109.x
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The transition to extra-uterine life at birth is critically dependent on airway liquid clearance to allow the entry of air and the onset of gaseous ventilation. We have used phase contrast X-ray imaging to identify factors that regulate lung aeration at birth in spontaneously breathing term and mechanically ventilated preterm rabbit pups. Phase contrast X-ray imaging exploits the difference in refractive index between air and water to enhance image contrast, enabling the smallest air-filled structures of the lung (alveoli; < 100 mu m) to be resolved. Using this technique, the lungs become visible as they aerate, allowing the air-liquid interface to be observed as it moves distally during lung aeration. Spontaneously breathing term rabbit pups rapidly aerate their lungs, with most fully recruiting their functional residual capacity (FRC) within the first few breaths. The increase in FRC occurs mainly during individual breaths, demonstrating that airway liquid clearance and lung aeration is closely associated with inspiration. We suggest that transpulmonary pressures generated by inspiration provide a hydrostatic pressure gradient for the movement of water out of the airways and into the surrounding lung tissue after birth. In mechanically ventilated preterm pups, lung aeration is closely associated with lung inflation and a positive end-expiratory pressure is required to generate and maintain FRC after birth. In summary, phase contrast X-ray imaging can image the air-filled lung with high temporal and spatial resolution and is ideal for identifying factors that regulate lung aeration at birth in both spontaneously breathing term and mechanically ventilated preterm neonates.
引用
收藏
页码:117 / 125
页数:9
相关论文
共 50 条
  • [41] A new formula of phase contrast imaging for continuous X-ray based on in-line X-ray imaging
    Xia, Tian
    Ma, Jun Shan
    Cheng, Jing Hai
    Yang, Jun
    COMPUTING, CONTROL, INFORMATION AND EDUCATION ENGINEERING, 2015, : 333 - 336
  • [42] Contrast enhancement of propagation based X-ray phase contrast imaging
    Pan, Adam
    Xu, Ling
    Petruccelli, Jon C.
    Gupta, Rajiv
    Barbastathis, George
    ADVANCES IN COMPUTATIONAL METHODS FOR X-RAY OPTICS III, 2014, 9209
  • [43] Contrast-to-noise in X-ray differential phase contrast imaging
    Engel, Klaus J.
    Geller, D.
    Koehler, T.
    Martens, G.
    Schusser, S.
    Vogtmeier, G.
    Roessl, E.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S202 - S207
  • [44] Fabrication of absorption gratings with X-ray lithography for X-ray phase contrast imaging
    Wang, Bo
    Wang, Yu-Ting
    Yi, Fu-Ting
    Zhang, Tian-Chong
    liu, Jing
    Zhou, Yue
    INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 2018, 32 (13):
  • [45] Phase-contrast X-ray imaging with a large monolithic X-ray interferometer
    Takeda, T
    Momose, A
    Yu, QW
    Wu, J
    Hirano, K
    Itai, Y
    JOURNAL OF SYNCHROTRON RADIATION, 2000, 7 (07) : 280 - 282
  • [46] Using measurements of the spatial SNR to optimize phase contrast X-ray imaging
    Ullherr, M.
    Balles, A.
    Fella, C.
    Zabler, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 877 : 44 - 50
  • [47] Experimental Research on Phase Contrast Imaging using a Desktop X-ray Tube
    Yan Ming
    Ma Ge
    Tang Bo
    Zhou Haisheng
    2016 9TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, BIOMEDICAL ENGINEERING AND INFORMATICS (CISP-BMEI 2016), 2016, : 1349 - 1353
  • [48] Compressed X-ray phase-contrast imaging using a coded source
    Sung, Yongjin
    Xu, Ling
    Nagarkar, Vivek
    Gupta, Rajiv
    OPTICS COMMUNICATIONS, 2014, 332 : 370 - 378
  • [49] Observation of Crack Propagation in Glass Using X-ray Phase Contrast Imaging
    Parab, Niranjan D.
    Black, John T.
    Claus, Benjamin
    Hudspeth, Matthew
    Sun, Jianzhuo
    Fezzaa, Kamel
    Chen, Weinong W.
    INTERNATIONAL JOURNAL OF APPLIED GLASS SCIENCE, 2014, 5 (04) : 363 - 373
  • [50] X-ray phase contrast imaging using single absorption coded aperture
    Krejci, Frantisek
    Jakubek, Jan
    Kroupa, Martin
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 633 : S181 - S184