X-ray phase contrast imaging using single absorption coded aperture

被引:5
|
作者
Krejci, Frantisek [1 ,2 ]
Jakubek, Jan [1 ]
Kroupa, Martin [1 ]
机构
[1] Czech Tech Univ, Inst Expt & Appl Phys, CZ-12800 Prague 2, Czech Republic
[2] Czech Tech Univ, Fac Biomed Engn, Kladno 27201, Czech Republic
关键词
X-ray imaging; Phase contrast; Coded aperture; Phase retrivial; Medipix; RESOLUTION;
D O I
10.1016/j.nima.2010.06.161
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new method for X-ray phase contrast imaging is proposed in which only one absorption grating (acting in fact as a coded aperture) and a table-top nano-focus X-ray source are used. This method is based on very precise determination of position of the projected pattern downstreaming from the aperture with and without the inspected object directly from the image of the pattern. The technique is successfully demonstrated on the table-top setup equipped with Medipix family detectors and a nano-focus X-ray source (source-to-detector distance < 1 m). (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:S181 / S184
页数:4
相关论文
共 50 条
  • [1] NEW APPROACH IN PHASE CONTRAST X-RAY IMAGING USING CODED APERTURE
    Krejci, Frantisek
    Jakubek, Jan
    Kroupa, Martin
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2010, 5 : 59 - 63
  • [2] Single-Step, Quantitative X-ray Differential Phase Contrast Imaging using Spectral Detection in a Coded Aperture Setup
    Das, Mini
    Liang, Zhihua
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [3] A coded-aperture technique allowing x-ray phase contrast imaging with conventional sources
    Olivo, Alessandro
    Speller, Robert
    APPLIED PHYSICS LETTERS, 2007, 91 (07)
  • [4] Image formation principles in coded-aperture based x-ray phase contrast imaging
    Olivo, A.
    Speller, R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (22): : 6461 - 6474
  • [5] Compressed X-ray phase-contrast imaging using a coded source
    Sung, Yongjin
    Xu, Ling
    Nagarkar, Vivek
    Gupta, Rajiv
    OPTICS COMMUNICATIONS, 2014, 332 : 370 - 378
  • [6] Evaluating the effects of source conditions on coded-aperture based X-ray phase contrast imaging
    Zhang, Cui
    Pan, Xiaodong
    Shang, Hongjie
    Ding, Jingjie
    Li, Gongping
    EUROPEAN PHYSICAL JOURNAL-APPLIED PHYSICS, 2018, 83 (01):
  • [7] A simplified approach to quantitative coded aperture X-ray phase imaging
    Munro, Peter R. T.
    Hagen, Charlotte K.
    Szafraniec, Magdalena B.
    Olivo, Alessandro
    OPTICS EXPRESS, 2013, 21 (09): : 11187 - 11201
  • [8] Challenges of Employing a High Resolution X-ray Detector in a Coded-Aperture X-ray Phase-Contrast Imaging system
    Pil-Ali, Abdollah
    Adnani, Sahar
    Scott, Christopher C.
    Karim, Karim S.
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [9] Design and realization of a coded-aperture based X-ray phase contrast imaging for homeland security applications
    Olivo, A.
    Ignatyev, K.
    Munro, P. R. T.
    Speller, R. D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 610 (02): : 604 - 614
  • [10] Approximated transport-of-intensity equation for coded-aperture x-ray phase-contrast imaging
    Das, Mini
    Liang, Zhihua
    OPTICS LETTERS, 2014, 39 (18) : 5395 - 5398