Validation of PRIMO Monte Carlo Model of Clinac®iX 6MV Photon Beam

被引:9
|
作者
Sarin, B. [1 ,2 ]
Bindhu, B. [1 ]
Saju, B. [2 ]
Nair, Raguram K. [2 ]
机构
[1] Noorul Islam Ctr Higher Educ, Dept Phys, Kanyakumari, Tamil Nadu, India
[2] Reg Canc Ctr, Div Radiat Phys, C Block,Room 3, Thiruvananthapuram 695011, Kerala, India
关键词
Clinac iX; Monte Carlo simulation; PENELOPE; PRIMO; DOSE-CALCULATION; DOSIMETRIC VALIDATION; SIMULATION; ALGORITHM; PENELOPE; CODE; XB;
D O I
10.4103/jmp.JMP_75_19
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study aims to model 6MV photon of Clinac (R) iX linear accelerator using PRIMO Monte Carlo (MC) code and to assess PRIMO as an independent MC-based dose verification and quality assurance tool. Materials and Methods: The modeling of Clinac (R) iX linear accelerator has been carried out by using PRIMO simulation software (Version 0.3.1.1681). The simulated beam parameters were compared against the measured beam data of the Clinac (R) iX machine. The PRIMO simulation model of Clinac (R) iX was also validated against Eclipse (R) Acuros XB dose calculations in the case of both homogenous and inhomogeneous mediums. The gamma analysis method with the acceptance criteria of 2%, 2 mm was used for the comparison of dose distributions. Results: Gamma analysis shows a minimum pass percentage of 99% for depth dose curves and 95.4% for beam profiles. The beam quality index and output factors and absolute point dose show good agreement with measurements. The validation of PRIMO dose calculations, in both homogeneous and inhomogeneous medium, against Acuros (R) XB shows a minimum gamma analysis pass rate of 99%. Conclusions: This study shows that the research software PRIMO can be used as a treatment planning system-independent quality assurance and dose verification tool in daily clinical practice. Further validation will be performed with different energies, complex multileaf collimators fields, and with dynamic treatment fields.
引用
收藏
页码:24 / 35
页数:12
相关论文
共 50 条
  • [1] Development of An Accurate Monte Carlo Model of the Standard Clinac 6MV Beam
    Egan, A.
    Laub, W.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [2] Commissioning of a Varian Clinac iX 6 MV Photon Beam using Monte Carlo Simulation
    Dirgayussa, I. Gde Eka
    Yani, Sitti
    Rhani, M. Fahdillah
    Haryanto, Freddy
    5TH INTERNATIONAL CONFERENCE ON MATHEMATICS AND NATURAL SCIENCES (ICMNS 2014), 2015, 1677
  • [3] Neutron contamination of Varian Clinac iX 10 MV photon beam using Monte Carlo simulation
    Yani, S.
    Tursinah, R.
    Rhani, M. F.
    Soh, R. C. X.
    Haryanto, F.
    Arif, I.
    13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [4] Monte carlo simulation of varian clinac iX 10 MV photon beam for small field dosimetry
    Yani, S.
    Rhani, M. F.
    Soh, R. C. X.
    Haryanto, F.
    Arif, I.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2017, 15 (03): : 275 - +
  • [5] Monte Carlo Model Validation of 6MV Beam of OMID, the First Iranian Linear Accelerator
    Abdoli, Mohammad Amin
    Hassanvand, Maryam
    Nejatbakhsh, Navid
    JOURNAL OF MEDICAL SIGNALS & SENSORS, 2024, 14 (08):
  • [6] The Effect of Voxel Size on Dose Distribution in Varian Clinac iX 6 MV Photon Beam Using Monte Carlo Simulation
    Yani, Sitti
    Dirgayussa, I. Gde E.
    Rhani, Moh Fadhillah
    Haryanto, Freddy
    Arif, Idam
    5TH INTERNATIONAL CONFERENCE ON MATHEMATICS AND NATURAL SCIENCES (ICMNS 2014), 2015, 1677
  • [7] Validation of the Elekta Synergy Platform Linac at 6 MV Photon Beam using PRIMO Monte Carlo Software
    Marzon, Jan Risty Lucido
    Convicto, Vernie C.
    Lapening, Melbagrace A.
    Berondo, Andelson L.
    Bacala, Angelina M.
    JOURNAL OF MEDICAL PHYSICS, 2024, 49 (03) : 410 - 418
  • [8] Validation of Monte Carlo Model for Dose Evaluation outside the Treatment Field for Siemens 6MV Beam
    Sinousy D.M.
    Attalla E.M.
    Fathy I.H.
    Elhussiny F.A.
    Elmekawy A.F.
    Sinousy, Dina Mohamed, 1600, Mashhad University of Medical Sciences (17): : 410 - 420
  • [9] Validation of BEAMnrc Monte Carlo model for a 12 MV photon beam
    Mohammed, Maged
    El Bardouni, T.
    Chakir, E.
    Saeed, M.
    Jamal, Al Zain
    Mohamed, Landour
    JOURNAL OF KING SAUD UNIVERSITY SCIENCE, 2018, 30 (04) : 537 - 543
  • [10] COMPARISON OF A MONTE CARLO 6MV LINAC MODEL WITH MEASURED 6MV BEAMS FOR PERIPHERAL DOSIMETRY
    Joosten, A.
    Levi, F.
    Baechier, S.
    Mirimanoff, R. O.
    Bochud, F.
    Moeckli, R.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S483 - S483