Inter-calibration of the CMS Barrel Electromagnetic Calorimeter Using π0 → γγ Decays

被引:0
|
作者
Yang, Y. [1 ]
机构
[1] CALTECH, Pasadena, CA 91125 USA
关键词
CMS; ECAL; Calibration;
D O I
10.1142/9789812819093_0068
中图分类号
O59 [应用物理学];
学科分类号
摘要
Inter-calibrating the electromagnetic calorimeter (ECAL) of the CMS detector in situ at the LHC to achieve the energy resolution approaching 0.5% at high energy is going to be important to fully exploit the physics reach of the detector, particularly for the discovery of the Higgs boson in the two-photon decay channel. In this paper we evaluate the potential of a calibration technique that makes use of photon pairs produced in neutral pion decays, pi(0) -> gamma gamma. Such photon pairs will be selected from the QCD events accepted by the Level-1 triggers using an online filter farm. Assuming a Level-1 trigger rate of 12.5 kHz, the rate of suitable neutral pions is found to be about 0.9 kHz. We show that 95% of the barrel electromagnetic calorimeter can be calibrated to at least 1% (0.5%) precision after several days (weeks) of data-taking in the low-luminosity scenario of LHC, L = 2 center dot 10(33) cm(-2) s(-1). In addition, we show that a 1% calibration precision is achieved with pi(0) decays produced in the pi(-) test beam runs during November 2006. The obtained calibration constants are successfully used for the reconstruction of 50 GeV electrons from the test beam data.
引用
收藏
页码:386 / 390
页数:5
相关论文
共 50 条
  • [41] Calibration and Performance of the CMS Electromagnetic Calorimeter in LHC Run2
    Cavallari, Francesca
    Rovelli, Chiara
    24TH INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS (CHEP 2019), 2020, 245
  • [42] Calibration and performance of the CMS Electromagnetic Calorimeter in LHC Run-II
    Kuo, C. M.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (06):
  • [43] Radiometric Inter-calibration of SAPHIR using the Microwave Humidity Sounders
    Ebrahimi, Hamideh
    Datta, Saswati
    Santos-Garcia, Andrea
    Jones, Linwood
    2014 13TH SPECIALIST MEETING ON MICROWAVE RADIOMETRY AND REMOTE SENSING OF THE ENVIRONMENT (MICRORAD), 2014, : 211 - 214
  • [44] Validation of the simulation of the CMS electromagnetic calorimeter using data
    Rovelli, Chiara
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2067 - 2069
  • [45] STAR barrel electromagnetic calorimeter absolute calibration using "minimum ionizing particles" from collisions at RHIC
    Cormier, TM
    Pavlinova, AI
    Rykov, MV
    Rykov, VL
    Shestermanov, KE
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 483 (03): : 734 - 746
  • [46] Calibration of the CMS Electromagnetic Calorimeter with √s=7 TeV LHC Collisions Data
    Di Matteo, Leonardo
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 1135 - 1137
  • [47] Transparency Variations and Calibration in CMS Electromagnetic Calorimeter Crystals: Monte Carlo Studies
    Chipaux, Remi
    Gentit, Francois-Xavier
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (03) : 1460 - 1464
  • [48] Cosmic ray calibration of the PbWO4 crystal electromagnetic calorimeter of CMS
    Franzoni, G.
    Calorimetry in High Energy Physics, 2006, 867 : 393 - 399
  • [49] Calibration of the very-front-end electronics for the electromagnetic calorimeter of the CMS experiment
    Blaha, J.
    Combaret, C.
    Fay, J.
    Maurelli, G.
    CZECHOSLOVAK JOURNAL OF PHYSICS, 2006, 56 : C401 - C408
  • [50] Inter-calibration of polar imager solar channels using SEVIRI
    Meirink, J. F.
    Roebeling, R. A.
    Stammes, P.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2013, 6 (09) : 2495 - 2508