Inter-calibration of the CMS Barrel Electromagnetic Calorimeter Using π0 → γγ Decays

被引:0
|
作者
Yang, Y. [1 ]
机构
[1] CALTECH, Pasadena, CA 91125 USA
关键词
CMS; ECAL; Calibration;
D O I
10.1142/9789812819093_0068
中图分类号
O59 [应用物理学];
学科分类号
摘要
Inter-calibrating the electromagnetic calorimeter (ECAL) of the CMS detector in situ at the LHC to achieve the energy resolution approaching 0.5% at high energy is going to be important to fully exploit the physics reach of the detector, particularly for the discovery of the Higgs boson in the two-photon decay channel. In this paper we evaluate the potential of a calibration technique that makes use of photon pairs produced in neutral pion decays, pi(0) -> gamma gamma. Such photon pairs will be selected from the QCD events accepted by the Level-1 triggers using an online filter farm. Assuming a Level-1 trigger rate of 12.5 kHz, the rate of suitable neutral pions is found to be about 0.9 kHz. We show that 95% of the barrel electromagnetic calorimeter can be calibrated to at least 1% (0.5%) precision after several days (weeks) of data-taking in the low-luminosity scenario of LHC, L = 2 center dot 10(33) cm(-2) s(-1). In addition, we show that a 1% calibration precision is achieved with pi(0) decays produced in the pi(-) test beam runs during November 2006. The obtained calibration constants are successfully used for the reconstruction of 50 GeV electrons from the test beam data.
引用
收藏
页码:386 / 390
页数:5
相关论文
共 50 条
  • [21] Calibration results of CMS electromagnetic calorimeter photodetectors
    Balandras, A
    Depasse, P
    Donini, J
    El Mamouni, H
    Fay, J
    Gascon-Shotkin, S
    Ille, B
    Lethuillier, M
    Ravat, O
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 504 (1-3): : 335 - 338
  • [22] In-situ calibration of the CMS electromagnetic calorimeter
    Futyan, DI
    PARTICLES AND THE UNIVERSE, 2004, : 211 - 217
  • [23] Intercalibration of the CMS Electromagnetic Calorimeter with Neutral Pion Decays
    Gataullin, M.
    Collaboration, C. M. S.
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2009, 197 : 147 - 150
  • [24] High precision, low disturbance calibration system for the CMS Barrel Electromagnetic Calorimeter High Voltage apparatus
    Fasanella, G.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [25] Calibration of the CMS Electromagnetic Calorimeter with first LHC data
    Obertino, M. M.
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2011, 215 : 182 - 184
  • [26] Calibration of the CMS electromagnetic calorimeter at the LHC start up
    Ghezzi, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 617 (1-3): : 88 - 89
  • [27] Calibration of the CMS electromagnetic calorimeter with LHC collision data
    Obertino, M. M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 718 : 99 - 101
  • [28] Final calibration results of CMS electromagnetic calorimeter photodetectors
    Depasse, P.
    El Mamouni, H.
    Fay, J.
    Gascon-Shotkin, S.
    Ille, B.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 567 (01): : 242 - 245
  • [29] Commissioning, Performance and Calibration of Crystals of the CMS Electromagnetic Calorimeter
    Yang, Yong
    35TH INTERNATIONAL CONFERENCE OF HIGH ENERGY PHYSICS (ICHEP 2010), 2010,