Ultrasensitive determination of ractopamine based on dual catalytic signal amplification by Pd nanocubes and HRP using a flow injection chemiluminescence immunoassay

被引:0
|
作者
Pei, Yingqi [1 ]
Zhang, Jing [2 ]
Wu, Kang [3 ]
Deng, Anping [1 ]
Li, Jianguo [1 ]
机构
[1] Soochow Univ, Key Lab Hlth Chem & Mol Diag Suzhou, Coll Chem Chem Engn & Mat Sci, Suzhou 215123, Peoples R China
[2] Shanghai Anim Dis Control Ctr, Shanghai 201103, Peoples R China
[3] Soochow Univ, Sch Biol & Basic Med Sci, Suzhou 215123, Peoples R China
基金
中国国家自然科学基金;
关键词
PEROXIDASE-LIKE ACTIVITY; NANOPARTICLES; GLUCOSE; CLENBUTEROL; EXTRACTION; RESIDUE; SENSOR; ASSAY;
D O I
10.1039/d0an01203c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid and highly sensitive flow injection chemiluminescence immunoassay was developed to detect ractopamine residues in pork products. Palladium nanocubes with excellent catalytic performance for a traditional luminol-PIP-H(2)O(2)chemiluminescence system were used as effective carriers to connect a ractopamine antibody and horseradish peroxidase (HRP). Double amplification of a chemiluminescence signal was realized because of palladium nanocubes and HRP. Carboxyl-modified resin beads were used as suitable materials to load ractopamine-coating antigens due to their good biocompatibility and large specific surface area. Based on the principle of competitive immunity, ractopamine standard solution would compete with antigen loaded on carboxyl resin beads for limited binding sites on a ractopamine antibody. Thus, the chemiluminescence intensity of an immunosensor has a linear negative correlation with the logarithm value of ractopamine concentration. Under optimal experimental conditions, the detection range of ractopamine was 0.005-1000 ng mL(-1), and the limit of detection (LOD) was 1.7 pg mL(-1)(S/N = 3). The proposed immunoassay possessed acceptable accuracy, high specificity and reproducibility and RAC was examined in pork and pig feed with satisfactory results, which would provide a better prospect for the detection of small molecules in food and environment analysis.
引用
收藏
页码:6171 / 6179
页数:9
相关论文
共 50 条
  • [41] A dual-signal output electrochemical immunosensor based on Au-MoS2/MOF catalytic cycle amplification strategy for neuron-specific enolase ultrasensitive detection
    Dong, Hui
    Liu, Shanghua
    Liu, Qing
    Li, Yueyuan
    Li, Yueyun
    Zhao, Zengdian
    BIOSENSORS & BIOELECTRONICS, 2022, 195
  • [42] Ultrasensitive sandwich-type electrochemical immunosensor based on dual signal amplification strategy using multifunctional graphenena nocomposites as labels for quantitative detection of tissue polypeptide antigen
    Wang, Yulan
    Wang, Yaoguang
    Pang, Xuehui
    Du, Bin
    Li, He
    Wu, Dan
    Wei, Qin
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 214 : 124 - 131
  • [43] Ultrasensitive assay of azithromycin in medicine and bio-fluids based on its enhanced luminol-H2O2 chemiluminescence reaction using flow injection technique
    Song, ZH
    Wang, CN
    BIOORGANIC & MEDICINAL CHEMISTRY, 2003, 11 (24) : 5375 - 5380
  • [44] A novel method for the determination of fluorescent whitening agent CBS in flour using flow-injection chemiluminescence based on a luminol-urea peroxide system
    He, Gaiyan
    Gao, Ruixia
    Hao, Yi
    Tang, Xiaoshuang
    ANALYTICAL METHODS, 2016, 8 (31) : 6082 - 6088
  • [45] Sulfur Quantum Dot-Based Electrochemiluminescence Resonance Energy Transfer System for a Dual-Mode Ultrasensitive Detection of MC-LR Using Ag+ as a Signal Amplification Switch
    Han, Yujie
    Du, Yu
    Xu, Kun
    Ren, Xiang
    Zhao, Guanhui
    Ru, Zhuangzhuang
    Jia, Yue
    Wei, Qin
    ANALYTICAL CHEMISTRY, 2023, 95 (22) : 8679 - 8686
  • [46] DETERMINATION OF VITAMIN A IN INFANT MILK-BASED FORMULAS AND PHARMACEUTICAL FORMULATIONS USING FLOW INJECTION WITH Ce(IV)-Na2SO3 CHEMILUMINESCENCE DETECTION
    Rishi, Lubna
    Yaqoob, Mohammad
    Asghar, Mohammad
    Shah, S. Haider
    Nabi, Abdul
    ANALYTICAL LETTERS, 2012, 45 (14) : 2037 - 2052
  • [47] A simple flow injection procedure for the determination of nanogram level norfloxacin in pharmaceutical preparations and biofluids using chemiluminescence detection based on its enhancement of potassium ferricyanide and luminol reaction
    Ying, Li
    LUMINESCENCE, 2012, 27 (02) : 176 - 176
  • [48] Dual-Modal Colorimetric and Surface-Enhanced Raman Scattering (SERS)-Based Lateral Flow Immunoassay for Ultrasensitive Detection of SARS-CoV-2 Using a Plasmonic Gold Nanocrown
    Atta, Supriya
    Zhao, Yuanhao
    Li, Joy Qiaoyi
    Vo-Dinh, Tuan
    ANALYTICAL CHEMISTRY, 2024, 96 (12) : 4783 - 4790
  • [49] Ultrasensitive point-of-care testing of salmonella in lettuce and milk samples using a recombinase polymerase amplification-based colorimetric/ fluorescent dual-readout lateral flow assay
    Feng, Jiaqi
    Xiong, Mengyuan
    Qiao, Yongsheng
    Wang, Ping
    Lin, Xianfeng
    Kang, Lixin
    Duan, Nuo
    Wang, Zhouping
    Wu, Shijia
    FOOD CHEMISTRY, 2025, 481
  • [50] Flow injection amperometric sandwich-type aptasensor for the determination of human leukemic lymphoblast cancer cells using MWCNTs-Pdnano/PTCA/aptamer as labeled aptamer for the signal amplification
    Tabrizi, Mahmoud Amouzadeh
    Shamsipur, Mojtaba
    Saber, Reza
    Sarkar, Saeed
    ANALYTICA CHIMICA ACTA, 2017, 985 : 61 - 68