Ultrasensitive determination of ractopamine based on dual catalytic signal amplification by Pd nanocubes and HRP using a flow injection chemiluminescence immunoassay

被引:0
|
作者
Pei, Yingqi [1 ]
Zhang, Jing [2 ]
Wu, Kang [3 ]
Deng, Anping [1 ]
Li, Jianguo [1 ]
机构
[1] Soochow Univ, Key Lab Hlth Chem & Mol Diag Suzhou, Coll Chem Chem Engn & Mat Sci, Suzhou 215123, Peoples R China
[2] Shanghai Anim Dis Control Ctr, Shanghai 201103, Peoples R China
[3] Soochow Univ, Sch Biol & Basic Med Sci, Suzhou 215123, Peoples R China
基金
中国国家自然科学基金;
关键词
PEROXIDASE-LIKE ACTIVITY; NANOPARTICLES; GLUCOSE; CLENBUTEROL; EXTRACTION; RESIDUE; SENSOR; ASSAY;
D O I
10.1039/d0an01203c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid and highly sensitive flow injection chemiluminescence immunoassay was developed to detect ractopamine residues in pork products. Palladium nanocubes with excellent catalytic performance for a traditional luminol-PIP-H(2)O(2)chemiluminescence system were used as effective carriers to connect a ractopamine antibody and horseradish peroxidase (HRP). Double amplification of a chemiluminescence signal was realized because of palladium nanocubes and HRP. Carboxyl-modified resin beads were used as suitable materials to load ractopamine-coating antigens due to their good biocompatibility and large specific surface area. Based on the principle of competitive immunity, ractopamine standard solution would compete with antigen loaded on carboxyl resin beads for limited binding sites on a ractopamine antibody. Thus, the chemiluminescence intensity of an immunosensor has a linear negative correlation with the logarithm value of ractopamine concentration. Under optimal experimental conditions, the detection range of ractopamine was 0.005-1000 ng mL(-1), and the limit of detection (LOD) was 1.7 pg mL(-1)(S/N = 3). The proposed immunoassay possessed acceptable accuracy, high specificity and reproducibility and RAC was examined in pork and pig feed with satisfactory results, which would provide a better prospect for the detection of small molecules in food and environment analysis.
引用
收藏
页码:6171 / 6179
页数:9
相关论文
共 50 条
  • [31] Sensitive Lateral Flow Immunoassay Based on Specific Peptide and Superior Oxidase Mimics with a Universal Dual-Mode Significant Signal Amplification
    Dong, Tao
    Zhang, Xin
    Yuan, Jinlong
    Lin, Ziting
    Yin, Pengxue
    Yu, Haipeng
    Wang, Mingyang
    Liu, Aihua
    ANALYTICAL CHEMISTRY, 2023, 95 (33) : 12532 - 12540
  • [32] Sensitive Chemiluminescence Immunoassay for E. coli O157:H7 Detection with Signal Dual-Amplification Using Glucose Oxidase and Laccase
    Zhag, Yun
    Tan, Chen
    Fei, Ruihua
    Liu, Xiaoxiao
    Zhou, Yuan
    Chen, Jing
    Chen, Huanchun
    Zhou, Rui
    Hu, Yonggang
    ANALYTICAL CHEMISTRY, 2014, 86 (02) : 1115 - 1122
  • [33] Ultrasensitive Ti3C2Tx@Pt-Based Immunochromatography with Catalytic Amplification and a Dual Signal for the Detection of Chloramphenicol in Animal-Derived Foods
    Lin, Mengfang
    Gao, Zhimin
    Qian, Zhenjie
    Deng, Youwen
    Chen, Yanhong
    Wang, Yu
    Li, Xiangmei
    FOODS, 2024, 13 (09)
  • [34] Pt@AuNF nanozyme and horseradish peroxidase-based lateral flow immunoassay dual enzymes signal amplification strategy for sensitive detection of zearalenone
    Qiao, Weili
    He, Baoshan
    Yang, Jun
    Ren, Wenjie
    Zhao, Renyong
    Zhang, Yurong
    Bai, Chunqi
    Suo, Zhiguang
    Xu, Yiwei
    Wei, Min
    Jin, Huali
    INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2024, 254
  • [35] A simple and sensitive flow injection method based on the catalytic activity of CdS quantum dots in an acidic permanganate chemiluminescence system for determination of formaldehyde in water and wastewater
    Khataee, Alireza
    Lotfi, Roya
    Hasanzadeh, Aliyeh
    Iranifam, Mortaza
    PHOTOCHEMICAL & PHOTOBIOLOGICAL SCIENCES, 2016, 15 (04) : 496 - 505
  • [36] A simple and sensitive flow injection method based on the catalytic activity of CdS quantum dots in an acidic permanganate chemiluminescence system for determination of formaldehyde in water and wastewater
    Alireza Khataee
    Roya Lotfi
    Aliyeh Hasanzadeh
    Mortaza Iranifam
    Photochemical & Photobiological Sciences, 2016, 15 : 496 - 505
  • [37] Ultrasensitive assay of rhein in medicine based on its enhanced luminol-K3Fe(CN)6 chemiluminescence reaction using the flow injection technique
    Liu, EB
    Xue, BC
    MICROCHIMICA ACTA, 2006, 153 (1-2) : 51 - 56
  • [38] Ultrasensitive Assay of Rhein in Medicine Based on its Enhanced Luminol-K3Fe(CN)6 Chemiluminescence Reaction Using the Flow Injection Technique
    Erbao Liu
    Bingchun Xue
    Microchimica Acta, 2006, 153 : 51 - 56
  • [39] A dual-signal output electrochemical aptasensor for glypican-3 ultrasensitive detection based on reduced graphene oxide-cuprous oxide nanozyme catalytic amplification strategy
    Li, Guiyin
    Feng, Huafu
    Li, Xinhao
    Li, Shengnan
    Liang, Jintao
    Zhou, Zhide
    BIOELECTROCHEMISTRY, 2024, 158
  • [40] Simultaneous Detection of Infectious Diseases Using Aptamer-Conjugated Gold Nanoparticles in the Lateral Flow Immunoassay-Based Signal Amplification Platform
    Kim, Jinwoo
    Baek, Sowon
    Nam, Jungmin
    Park, Jeongeun
    Kim, Kihyeun
    Kang, Juyoung
    Yeom, Gyuho
    ANALYTICAL CHEMISTRY, 2024, 96 (04) : 1725 - 1732