In situ cryo-FIB/SEM Specimen Preparation Using the Waffle Method

被引:5
|
作者
Klykov, Oleg [1 ]
Bobe, Daija [1 ]
Paraan, Mohammadreza [1 ]
Johnston, Jake D. [1 ,2 ]
Potter, Clinton S. [1 ,3 ]
Carragher, Bridget [1 ,3 ]
Kopylov, Mykhailo [1 ]
Noble, Alex J. [1 ]
机构
[1] New York Struct Biol Ctr, Simons Electron Microscopy Ctr, Natl Ctr Insitu Tomog Ultramicroscopy, New York, NY 10027 USA
[2] Columbia Univ, Dept Physiol & Cellular Biophys, New York, NY USA
[3] Columbia Univ, Dept Biochem & Mol Biophys, New York, NY USA
来源
BIO-PROTOCOL | 2022年 / 12卷 / 21期
关键词
FIB; -SEM; HPF; Waffle Method; cryo-ET; Sample preparation; In situ; AutoTEM Cryo; ELECTRON-MICROSCOPY; EM;
D O I
10.21769/BioProtoc.4544
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Cryo-focused ion beam (FIB) milling of vitrified specimens is emerging as a powerful method for in situ specimen preparation. It allows for the preservation of native and near-native conditions in cells, and can reveal the molecular structure of protein complexes when combined with cryo-electron tomography (cryo-ET) and sub-tomogram averaging. Cryo-FIB milling is often performed on plunge-frozen specimens of limited thickness. However, this approach may have several disadvantages, including low throughput for cells that are small, or at low concentration, or poorly distributed across accessible areas of the grid, as well as for samples that may adopt a preferred orientation. Here, we present a detailed description of the "Waffle Method" protocol for vitrifying thick specimens followed by a semi-automated milling procedure using the Thermo Fisher Scientific (TFS) Aquilos 2 cryo-FIB/scanning electron microscope (SEM) instrument and AutoTEM Cryo software to produce cryo-lamellae. With this protocol, cryolamellae may be generated from specimens, such as microsporidia spores, yeast, bacteria, and mammalian cells, as well as purified proteins and protein complexes. An experienced lab can perform the entire protocol presented here within an 8-hour working day, resulting in two to three cryo-lamellae with target thicknesses of 100-200 nm and dimensions of approximately 12 mu m width and 15-20 mu m length. For cryo-FIB/SEMs with particularly lowcontamination chambers, the protocol can be extended to overnight milling, resulting in up to 16 cryo-lamellae in
引用
收藏
页数:16
相关论文
共 50 条
  • [31] In situ fiducial markers for 3D correlative cryo-fluorescence and FIB-SEM imaging
    Scher, Nadav
    Rechav, Katya
    Paul-Gilloteaux, Perrine
    Avinoam, Ori
    [J]. ISCIENCE, 2021, 24 (07)
  • [32] A three-dimensional reconstruction of coal microstructure using the Cryo-FIB-SEM technique
    Zakrzewski, Marcin
    Schertel, Andreas
    Brus, Grzegorz
    Wagner, Marian
    Sciazko, Anna
    Komatsu, Yosuke
    Kimijima, Shinji
    Kaneko, Shozo
    Szmyd, Janusz S.
    [J]. FUEL, 2020, 275
  • [33] Recent development in a TEM specimen preparation technique using FIB for semiconductor devices
    Nakahara, S
    [J]. SURFACE & COATINGS TECHNOLOGY, 2003, 169 : 721 - 727
  • [34] Target preparation of TEM samples using SEM observation in a double-beam FIB
    Altmann, F
    [J]. PRAKTISCHE METALLOGRAPHIE-PRACTICAL METALLOGRAPHY, 2005, 42 (04): : 206 - 212
  • [35] Warp-Free TEM Sample Preparation Methods Using FIB/SEM Systems
    Cook, Steven R.
    [J]. MICROSCOPY AND MICROANALYSIS, 2022, 28 (06) : 1961 - 1970
  • [36] VHUT-cryo-FIB, a method to fabricate frozen hydrated lamellae from tissue specimens for in situ cryo-electron tomography
    Zhang, Jianguo
    Zhang, Danyang
    Sun, Lei
    Ji, Gang
    Huang, Xiaojun
    Niu, Tongxin
    Xu, Jiashu
    Ma, Chengying
    Zhu, Yun
    Gao, Ning
    Xu, Wei
    Sun, Fei
    [J]. JOURNAL OF STRUCTURAL BIOLOGY, 2021, 213 (03)
  • [37] Overview on established and novel FIB based miniaturized mechanical testing using in-situ SEM
    Kiener, Daniel
    Motz, Christian
    Dehm, Gerhard
    Pippan, Reinhard
    [J]. INTERNATIONAL JOURNAL OF MATERIALS RESEARCH, 2009, 100 (08) : 1074 - 1087
  • [38] BIOLOGICAL SPECIMEN PREPARATION FOR SEM BY A METHOD OTHER THAN CRITICAL-POINT DRYING
    ADAMS, JL
    BATTJES, CJ
    BUTHALA, DA
    [J]. JOURNAL OF ELECTRON MICROSCOPY TECHNIQUE, 1987, 6 (03): : 315 - 315
  • [39] Optimizing the SEM specimen preparation method for accurate microanalysis of carbon nanotube/nanocluster hybrids
    Yue, Nailin
    Wang, Li
    He, Xingquan
    Liu, Hongyan
    Zhang, Wei
    [J]. JOURNAL OF MICROSCOPY, 2021, 282 (03) : 267 - 273
  • [40] TEM analysis of galvanized steel using the FIB lift-out specimen preparation technique
    Giannuzzi, LA
    Kempshall, BW
    Urbanik, CA
    Prenitzer, BI
    Drown, JL
    Shofner, T
    Brown, SR
    Irwin, RB
    Stevie, FA
    [J]. 9TH CONTINUOUS STEEL STRIP PLATING SYMPOSIUM, PROCEEDINGS, 1999, : 163 - 166