A multi-beam x-ray imaging system based on carbon nanotube field emitters - art. no. 614204

被引:12
|
作者
Zhang, J. [1 ]
Yang, G. [1 ]
Lee, Y. Z. [1 ]
Cheng, Y. [1 ]
Gao, B. [1 ]
Qiu, Q. [1 ]
Lu, J. P. [1 ]
Zhou, O. [1 ]
机构
[1] Univ N Carolina, Dept Phys & Astron, Chapel Hill, NC 27599 USA
关键词
carbon nanotube; field emission; multi-beam x-ray source; tomosynthesis;
D O I
10.1117/12.654006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this study, we report a multi-beam x-ray imaging system that can generate a scanning x-ray beam to image an object from multiple projection angles without mechanical motion. The key part of this imaging system is a multi-beam field emission x-ray (MBFEX) source which comprises a linear array of gated electron emitting pixels. The pixels are individually addressable via a MOSFET (metal-oxide-semiconductor field effect transistor) based electronic circuit. The device can provide a tube current of 0.1-1 mA at 40 kVp with less than 3 00 gm focal spot size from each of the emitting pixels. Multilayer images of different phantoms were reconstructed to demonstrate its potential applications in tomographic imaging. Since no mechanical motion is needed and the electronic switching time is generally negligible the MBFEX system has the potential to simplify the system design and lead to a fast data acquisition for tomographic imaging.
引用
收藏
页码:14204 / 14204
页数:8
相关论文
共 50 条
  • [41] Direct Synthesis of Carbon Nanotube Field Emitters on Metal Substrate for Open-Type X-ray Source in Medical Imaging
    Gupta, Amar Prasad
    Park, Sangjun
    Yeo, Seung Jun
    Jung, Jaeik
    Cho, Chonggil
    Paik, Sang Hyun
    Park, Hunkuk
    Cho, Young Chul
    Kim, Seung Hoon
    Shin, Ji Hoon
    Ahn, Jeung Sun
    Ryu, Jehwang
    MATERIALS, 2017, 10 (08):
  • [42] Biomedical X-ray Imaging Enabled by Carbon Nanotube X-ray Sources
    Cao, Guohua
    CHINESE JOURNAL OF CHEMICAL PHYSICS, 2018, 31 (04) : 529 - 536
  • [43] Determination of Dosimetric Parameters for Vacuum-Sealed Miniature X-Ray Tube Based On Carbon Nanotube Field Emitters
    Kang, S.
    Chung, J.
    Kim, K.
    Kang, S.
    Eom, K.
    Song, C.
    Kim, J.
    Suh, T.
    MEDICAL PHYSICS, 2018, 45 (06) : E239 - E239
  • [44] Fabrication of multi-blade crystals for hard-X-ray multi-beam imaging system
    Yashiro, Wataru
    Liang, Xiaoyu
    Voegeli, Wolfgang
    Wada, Takeshi
    Kato, Hidemi
    Kajiwara, Kentaro
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2020, 59 (09)
  • [45] X-ray multi-beam diffraction and imaging at a 90° Bragg reflection with partially coherent radiation
    Nikulin, AY
    Souvorov, A
    Goodden, K
    Tamasaku, K
    Ishikawa, T
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2003, 36 (10A) : A87 - A92
  • [46] Polarimetry with a soft X-ray spectrometer - art. no. 701129
    Aarshall, Herman L.
    SPACE TELESCOPES AND INSTRUMENTATION 2008: ULTRAVIOLET TO GAMMA RAY, PTS 1 AND 2, 2008, 7011 : 1129 - 1129
  • [47] X-ray interferometry with microelectronvolt resolution -: art. no. 013904
    Shvyd'ko, YV
    Lerche, M
    Wille, HC
    Gerdau, E
    Lucht, M
    Rüter, HD
    Alp, EE
    Khachatryan, R
    PHYSICAL REVIEW LETTERS, 2003, 90 (01)
  • [48] Reply to "Comment on 'Correlation of x-ray absorption and x-ray photoemission spectroscopies in amorphous carbon nitride' " -: art. no. 016202
    Ripalda, JM
    Román, E
    Díaz, N
    Galán, L
    Montero, I
    Comelli, G
    Baraldi, A
    Lizzit, S
    Goldoni, A
    Paolucci, G
    PHYSICAL REVIEW B, 2001, 64 (01)
  • [49] CNTs Used to Produce Multi-Beam Scanning Field-Emission X-Ray Source
    Shiming Wu
    MRS Bulletin, 2005, 30 : 502 - 503
  • [50] CNTs used to produce multi-beam scanning field-emission x-ray source
    Wu, SM
    MRS BULLETIN, 2005, 30 (07) : 502 - 502