A multi-beam x-ray imaging system based on carbon nanotube field emitters - art. no. 614204

被引:12
|
作者
Zhang, J. [1 ]
Yang, G. [1 ]
Lee, Y. Z. [1 ]
Cheng, Y. [1 ]
Gao, B. [1 ]
Qiu, Q. [1 ]
Lu, J. P. [1 ]
Zhou, O. [1 ]
机构
[1] Univ N Carolina, Dept Phys & Astron, Chapel Hill, NC 27599 USA
来源
Medical Imaging 2006: Physics of Medical Imaging, Pts 1-3 | 2006年 / 6142卷
关键词
carbon nanotube; field emission; multi-beam x-ray source; tomosynthesis;
D O I
10.1117/12.654006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this study, we report a multi-beam x-ray imaging system that can generate a scanning x-ray beam to image an object from multiple projection angles without mechanical motion. The key part of this imaging system is a multi-beam field emission x-ray (MBFEX) source which comprises a linear array of gated electron emitting pixels. The pixels are individually addressable via a MOSFET (metal-oxide-semiconductor field effect transistor) based electronic circuit. The device can provide a tube current of 0.1-1 mA at 40 kVp with less than 3 00 gm focal spot size from each of the emitting pixels. Multilayer images of different phantoms were reconstructed to demonstrate its potential applications in tomographic imaging. Since no mechanical motion is needed and the electronic switching time is generally negligible the MBFEX system has the potential to simplify the system design and lead to a fast data acquisition for tomographic imaging.
引用
收藏
页码:14204 / 14204
页数:8
相关论文
共 50 条
  • [31] Multi-beam X-ray ptychography for high-throughput coherent diffraction imaging
    Yao, Yudong
    Jiang, Yi
    Klug, Jeffrey A.
    Wojcik, Michael
    Maxey, Evan R.
    Sirica, Nicholas S.
    Roehrig, Christian
    Cai, Zhonghou
    Vogt, Stefan
    Lai, Barry
    Deng, Junjing
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [32] A Fully Closed Nano-Focus X-Ray Source With Carbon Nanotube Field Emitters
    Park, Sora
    Kang, Jun-Tae
    Jeong, Jin-Woo
    Kim, Jae-Woo
    Yun, Ki Nam
    Jeon, Hyojin
    Go, Eunsol
    Lee, Jeong-Woong
    Ahn, Yujung
    Yeon, Ji-Hwan
    Kim, Sunghee
    Song, Yoon-Ho
    IEEE ELECTRON DEVICE LETTERS, 2018, 39 (12) : 1936 - 1939
  • [33] Development of fully vacuum-sealed X-ray tubes with carbon nanotube field emitters
    Song, Yoon-Ho
    Kim, Jae-Woo
    Jeong, Jin-Woo
    Kang, Jun-Tae
    Choi, Sungyoul
    Choi, Kyoung Eun
    Ahn, Sung-Jun
    2012 25TH INTERNATIONAL VACUUM NANOELECTRONICS CONFERENCE (IVNC), 2012, : 20 - 20
  • [34] Transmission-type microfocus x-ray tube using carbon nanotube field emitters
    Heo, Sung Hwan
    Ihsan, Aamir
    Cho, Sung Oh
    APPLIED PHYSICS LETTERS, 2007, 90 (18)
  • [35] Development and assessment of a multi-beam continuous-phantom-motion x-ray scatter projection imaging system
    Dydula, Christopher
    Belev, George
    Johns, Paul C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (03):
  • [36] Energy response of the X-ray Imaging Spectrometer (XIS) on Suzaku - art. no. 626641
    Matsumoto, Hironori
    Nakajima, Hiroshi
    Yamaguchi, Hiroya
    Tsuru, Takeshi G.
    Koyama, Katsuji
    Hayashida, Kiyoshi
    Torii, Ken'ichi
    Namiki, Masaaki
    Tsunemi, Hiroshi
    Murakami, Hiroshi
    Ozaki, Masanobu
    Dotani, Tadayasu
    LaMarr, Beverly
    Kissel, Steven E.
    Bautz, Mark W.
    Space Telescopes and Instrumentation II: Ultraviolet to Gamma Ray, Pts 1 and 2, 2006, 6266 : 26641 - 26641
  • [37] Carbon Nanotube Field Emission X-ray System for Computed Tomography
    Ryu, Je Hwang
    Kim, Wan Sun
    Lee, Seung Ho
    Kang, Jung Su
    Kim, Jae Gon
    Lee, Soo Yeol
    Park, Kyu Chang
    Park, Hun Kuk
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [38] Analysis of the π* and σ* bands of the x-ray absorption spectrum of amorphous carbon -: art. no. 125204
    Díaz, J
    Anders, S
    Zhou, X
    Moler, EJ
    Kellar, SA
    Hussain, Z
    PHYSICAL REVIEW B, 2001, 64 (12)
  • [39] Tomosynthesis reconstruction from multi-beam X-ray sources
    Lalush, David S.
    Quan, Enzhuo
    Rajaram, Ramya
    Zhang, Jian
    Lu, Jianping
    Zhou, Otto
    2006 3RD IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1-3, 2006, : 1180 - +
  • [40] A novel gantry-free DBT system using a stationary multi-beam field emission X-ray source array based on carbon nanotubes (CNTs)
    Yang, G.
    Rajaram, R.
    Zhang, J.
    Sultana, S.
    Cao, G.
    Lalush, D.
    Lu, J.
    Zhou, O.
    MEDICAL PHYSICS, 2007, 34 (06) : 2347 - 2347