Mapping and quantifying hyperpolarized 3He magnetic resonance imaging apparent diffusion coefficient gradients

被引:21
|
作者
Evans, Andrea [1 ,2 ]
McCormack, David G. [3 ,4 ]
Santyr, Giles [1 ,2 ,5 ]
Parraga, Grace [1 ,2 ,4 ,5 ]
机构
[1] Univ Western Ontario, Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
[2] Univ Western Ontario, Dept Med Biophys, London, ON N6A 5K8, Canada
[3] Univ Western Ontario, Dept Med, Div Respirol, London, ON N6A 5K8, Canada
[4] Univ Western Ontario, Lawson Hlth Res Inst, London, ON N6A 5K8, Canada
[5] Univ Western Ontario, Dept Radiol & Nucl Med, London, ON N6A 5K8, Canada
关键词
emphysema; chronic obstructive pulmonary disease; thoracic imaging; noble gas lung imaging;
D O I
10.1152/japplphysiol.00178.2008
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
We measured hyperpolarized He-3 magnetic resonance imaging (MRI) apparent diffusion coefficients (ADC) and quantified ADC gradients in each three-by-three voxel region of interest (ROI). Such local ADC gradients can be represented in vector maps showing the magnitude (vertical bar G(3x3)vertical bar) and direction of ADC gradients, providing a qualitative visualization tool and quantitative measurement of airway and air space heterogeneity. Twenty-four subjects (15 male, mean age = 67 +/- 7 yr) with global initiative for chronic obstructive lung disease (GOLD) stage II (n = 9, mean age 68 +/- 6 yr), GOLD stage III chronic obstructive pulmonary disease (COPD; n = 7, mean age 67 +/- 8 yr), and age- matched healthy volunteers (n = 8, mean age 67 +/- 6 yr) were enrolled based on their age and spirometry results. Hyperpolarized 3He MRI was performed on a whole body 3.0 Tesla system. Mean He-3 ADC and ADC standard deviation were calculated for the center coronal slice, and the mean magnitude and direction of the ADC gradient vectors were calculated for each three- by- three voxel matrix (vertical bar G(3x3)vertical bar). While the He-3 ADC standard deviation was not significantly different, mean vertical bar G(3x3)vertical bar was significantly different between subjects with stage II (0.14 +/- 0.03 cm/s) and stage III COPD (0.19 +/- 0.03 cm/s; P < 0.005) and between healthy subjects (0.12 +/- 0.03 cm/ s) and those with stage II COPD (P < 0.02). The second order statistic vertical bar G(3x3)vertical bar may provide a sensitive measure of ADC heterogeneity for ROI representing 9.4 x 9.4 x 30 mm or 2.6 cm(3) of lung tissue.
引用
收藏
页码:693 / 699
页数:7
相关论文
共 50 条
  • [41] The apparent diffusion coefficient at 3He MRI:: Analysis of airspace size at in- and expiration
    Bink, A
    Hanisch, G
    Lill, J
    Schreiber, WG
    Thelen, M
    Kauczor, H
    RADIOLOGY, 2001, 221 : 631 - 631
  • [42] How Do Exercise Responses Relate To 3he Magnetic Resonance Imaging Apparent Diffusion Coefficients In Older Never-Smokers?
    Sheikh, K.
    Paulin, G.
    Svenningsen, S.
    McCormack, D. G.
    Neder, J. A.
    Parraga, G.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2015, 191
  • [43] Long-Range Diffusion of Hyperpolarized 3He in Rats
    Rodriguez, Ignacio
    Perez-Sanchez, Jose Manuel
    Peces-Barba, German
    Kaulisch, Thomas
    Stiller, Detlef
    Ruiz-Cabello, Jesus
    MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (01) : 54 - 58
  • [44] Hyperpolarized 3He and perfluorocarbon gas diffusion MRI of lungs
    Conradi, MS
    Saam, BT
    Yablonskiy, DA
    Woods, JC
    PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY, 2006, 48 (01) : 63 - 83
  • [45] Quantification of lung microstructure with hyperpolarized 3He diffusion MRI
    Yablonskiy, Dmitriy A.
    Sukstanskii, Alexander L.
    Woods, Jason C.
    Gierada, David S.
    Quirk, James D.
    Hogg, James C.
    Cooper, Joel D.
    Conradi, Mark S.
    JOURNAL OF APPLIED PHYSIOLOGY, 2009, 107 (04) : 1258 - 1265
  • [46] 3He spin exchange cells for magnetic resonance imaging
    Jacob, R.E., 1600, American Institute of Physics Inc. (92):
  • [47] Hyperpolarized 3He diffusion MRI and histology in pulmonary emphysema
    Woods, Jason C.
    Choong, Cliff K.
    Yablonskiy, Dmitriy A.
    Bentley, John
    Wong, Jonathan
    Pierce, John A.
    Cooper, Joel D.
    Macklem, Peter T.
    Conradi, Mark S.
    Hogg, James C.
    MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (06) : 1293 - 1300
  • [48] Polarisation and compression of 3He for magnetic resonance imaging purposes
    Geurts, DG
    van den Brand, JFJ
    Bulten, HJ
    Ferro-Luzzi, M
    Nicolay, K
    Poolman, HR
    POLARIZED GAS TARGETS AND POLARIZED BEAMS - SEVENTH INTERNATIONAL WORKSHOP, 1998, (421): : 459 - 460
  • [49] Recycling of 3He from lung magnetic resonance imaging
    Salhi, Z.
    Grossmann, T.
    Gueldner, M.
    Heil, W.
    Karpuk, S.
    Otten, E. W.
    Rudersdorf, D.
    Surkau, R.
    Wolf, U.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (06) : 1758 - 1763
  • [50] Pulmonary 3He magnetic resonance imaging of childhood asthma
    Cadman, Robert V.
    Lemanske, Robert F., Jr.
    Evans, Michael D.
    Jackson, Daniel J.
    Gern, James E.
    Sorkness, Ronald L.
    Fain, Sean B.
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2013, 131 (02) : 369 - +