'Time apodization' of ultrasonic transducer arrays

被引:0
|
作者
Cincotti, G [1 ]
Cardone, G [1 ]
Gori, P [1 ]
Pomata, F [1 ]
Pappalardo, M [1 ]
机构
[1] Univ Roma Tre, Dipartimento Ingn Elettron, I-00146 Rome, Italy
关键词
transmit beamforming; apodization; contrast resolution;
D O I
10.1117/12.350664
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new apodization technique to enhance the contrast resolution of medical ultrasonic imaging systems is presented. It can easily be implemented on any commercial transducer array. The array aperture windowing in the transmitting mode is performed without modifying the driver voltage over the whole army, but only varying the driving pulse length from an element to another. A design curve has been determined which transforms any conventional amplitude apodization into a 'time apodization'. Experimental and numerical results are given for a 3.5 NHz convex array and for a 2.5 MHz phased array. They demonstrate the effectiveness of this method in reducing the off-axis energy ill the radiated pattern. Moreover, they point out that 'time apodization' improves also the range resolution, since the overall length of the ultrasonic pulse transmitted by the probe is reduced.
引用
收藏
页码:101 / 107
页数:7
相关论文
共 50 条
  • [1] Physical apodization of ultrasonic arrays
    Olbrish, KD
    Shung, KK
    ULTRASONIC TRANSDUCER ENGINEERING: MEDICAL IMAGING 1997, 1997, 3037 : 196 - 205
  • [2] ULTRASONIC TRANSDUCER ARRAYS FOR REAL-TIME TOMOGRAPHY OF HEART
    WHITTINGHAM, TA
    PHYSICS IN MEDICINE AND BIOLOGY, 1975, 20 (03): : 498 - 498
  • [3] Tolerance analysis and apodization processing of medical ultrasonic array transducer wave beams
    Wang, Bo
    Wan, Mingxi
    Wang, Supin
    Chen, Zhongmin
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 1999, 33 (03): : 5 - 9
  • [4] Study of Crosstalk in Linear Ultrasonic Transducer Arrays
    Celmer, Mateusz
    Opielinski, Krzysztof J.
    ACTA ACUSTICA UNITED WITH ACUSTICA, 2015, 101 (01) : 46 - 54
  • [5] Piezoelectric thick films for ultrasonic transducer arrays
    Hackenberger, WS
    Shrout, TR
    Pickrell, DP
    1996 INTERNATIONAL SYMPOSIUM ON MICROELECTRONICS, 1996, 2920 : 71 - 76
  • [6] THEORY FOR CROSS COUPLING IN ULTRASONIC TRANSDUCER ARRAYS
    BAER, RL
    KINO, GS
    APPLIED PHYSICS LETTERS, 1984, 44 (10) : 954 - 956
  • [7] ULTRASONIC TRANSDUCERS AND TRANSDUCER ARRAYS FOR APPLICATIONS IN AIR
    MANTHEY, W
    KROEMER, N
    MAGORI, V
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1992, 3 (03) : 249 - 261
  • [8] ULTRASONIC REFLECTIVITY TOMOGRAPHY - RECONSTRUCTION WITH CIRCULAR TRANSDUCER ARRAYS
    NORTON, SJ
    LINZER, M
    ULTRASONIC IMAGING, 1979, 1 (02) : 154 - 184
  • [9] Transparent capacitive micromachined ultrasonic transducer (CMUT) arrays for real-time photoacoustic applications
    Ilkhechi, Afshin Kashani
    Ceroici, Christopher
    Li, Zhenhao
    Zemp, Roger
    OPTICS EXPRESS, 2020, 28 (09) : 13750 - 13760
  • [10] Medical imaging using capacitive micromachined ultrasonic transducer arrays
    Johnson, J
    Oralkan, Ö
    Demirci, U
    Ergun, S
    Karaman, M
    Khuri-Yakub, P
    ULTRASONICS, 2002, 40 (1-8) : 471 - 476