Study on Acoustic Catheter of Boiler Tube Leakage Monitoring Systems

被引:0
|
作者
Lv, Yongxing [1 ]
Feng, Qiang [1 ]
机构
[1] North China Elect Power Univ, Beijing, Peoples R China
关键词
power station; boiler; four tube leakage; resonance cavity; acoustic catheter; FAULT-DETECTION; DIAGNOSIS; SENSOR;
D O I
10.1016/j.phpro.2012.05.115
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Boiler tube leakage is the major reason of affecting the safe operation of the unit now, there are 3 methods of the "four tube" leakage detection: Traditional method, filtering method and acoustic spectrum analysis, acoustic spectrum analysis is the common method, but this method have low sensitivity and the sensor damage easily. Therewith, designed the special acoustic catheter with acoustic resonance cavity type, proved by experiments, the acoustic catheter with acoustic resonance cavity type can enhance leakage sound, can accurately extract leakage signals, has high sensitivity, and can avoid the effect of sensor by fire and hot-gas when the furnace is in positive pressure situation, reduce the installation and maintenance costs of the boiler tube leakage monitor system. (C) 2012 Published by Elsevier B.V. Selection and/or peer review under responsibility of ICMPBE International Committee.
引用
收藏
页码:641 / 646
页数:6
相关论文
共 50 条
  • [41] A Fiber Optic Acoustic Pyrometer for Temperature Monitoring in an Exhaust Pipe of a Boiler
    Zhou, Jingcheng
    Guo, Xu
    Du, Cong
    Lou, Xinsheng
    Cao, Chengyu
    Wang, Xingwei
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2019, 31 (19) : 1580 - 1583
  • [42] Real-time monitoring on boiler combustion based on acoustic measurement
    Shen, G. Q.
    An, L. S.
    Jiang, G. S.
    2006 IEEE POWER INDIA CONFERENCE, VOLS 1 AND 2, 2006, : 792 - +
  • [43] Discriminability Analysis of Characterization Parameters in Micro-Leakage of Turbocharged Boiler's Evaporation Tube
    Li, Dongliang
    Xia, Shaojun
    Geng, Jianghua
    Meng, Fankai
    Chen, Yutao
    Zhu, Guoqing
    ENERGIES, 2022, 15 (22)
  • [44] ACOUSTIC MONITORING OF NUCLEAR-PLANT OPERATING VALVES FOR LEAKAGE
    JONES, RM
    MATERIALS EVALUATION, 1989, 47 (11) : 1278 - 1285
  • [45] Detecting pneumatic actuator leakage using acoustic emission monitoring
    Mahmoud, H.
    Mazal, P.
    Vlasic, F.
    INSIGHT, 2020, 62 (01) : 22 - 26
  • [46] Leakage Localization with an Acoustic Array that Covers a Wide Area for Pipeline Leakage Monitoring in a Closed Space
    Park, Choon-Su
    Jeon, Jong-Hoon
    Park, Jin-Ho
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2013, 33 (05) : 422 - 429
  • [47] Combustion monitoring of a water tube boiler using a discriminant radial basis network
    Sujatha, K.
    Pappa, N.
    ISA TRANSACTIONS, 2011, 50 (01) : 101 - 110
  • [48] Study on Voice Transmission System of the Optical Fiber for Tube Leakage Monitoring Installment in the Power Station Boile
    Xu Yuan-zhe
    Chen Hong-zhen
    Ma Shu-jing
    Zhao Chang-jun
    MANUFACTURING SCIENCE AND TECHNOLOGY, PTS 1-8, 2012, 383-390 : 260 - 266
  • [49] Study on Noise Monitoring and Evaluation of Boiler Room
    Zhou, Ji-hong
    Wang, Bin
    NANOTECHNOLOGY AND COMPUTER ENGINEERING, 2010, 121-122 : 782 - 786
  • [50] Monitoring ash fouling in power station boiler furnaces using acoustic pyrometry
    Zhang, Shiping
    Shen, Guoqing
    An, Liansuo
    Niu, Yuguang
    Jiang, Genshan
    CHEMICAL ENGINEERING SCIENCE, 2015, 126 : 216 - 223