摘要
Boiler tube leakage is the major reason of affecting the safe operation of the unit now, there are 3 methods of the "four tube" leakage detection: Traditional method, filtering method and acoustic spectrum analysis, acoustic spectrum analysis is the common method, but this method have low sensitivity and the sensor damage easily. Therewith, designed the special acoustic catheter with acoustic resonance cavity type, proved by experiments, the acoustic catheter with acoustic resonance cavity type can enhance leakage sound, can accurately extract leakage signals, has high sensitivity, and can avoid the effect of sensor by fire and hot-gas when the furnace is in positive pressure situation, reduce the installation and maintenance costs of the boiler tube leakage monitor system. (C) 2012 Published by Elsevier B.V. Selection and/or peer review under responsibility of ICMPBE International Committee.
引用
收藏
页码:641 / 646
页数:6
相关论文
共 50 条
  • [31] Digital radiographic systems detect boiler tube cracks
    Walker, Stan
    POWER, 2008, 152 (06) : 34 - 38
  • [32] Tube leak detection and isolation in industrial boiler systems
    Alouani, AT
    APPLICATIONS AND SCIENCE OF COMPUTATIONAL INTELLIGENCE II, 1999, 3722 : 134 - 143
  • [33] Feasibility study of magnetic flux leakage method for condition monitoring of wall thinning on tube
    Kikuchi, Hiroaki
    Kurisawa, Yumi
    Ara, Katsuyuki
    Kamada, Yasuhiro
    Kobayashi, Satoru
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2010, 33 (3-4) : 1087 - 1094
  • [34] Feasibility Study of Magnetic Flux Leakage Method for Condition Monitoring of Wall Thinning on Tube
    Kikuchi, Hiroaki
    Kurisawa, Yumi
    Ara, Katsuyuki
    Kamada, Yasuhiro
    Kobayashi, Satoru
    APPLIED ELECTROMAGNETICS AND MECHANICS (II), 2009, 13 : 393 - 394
  • [35] Ash fouling monitoring based on acoustic pyrometry in boiler furnaces
    Zhang, Shiping
    Shen, Guoqing
    An, Liansuo
    Li, Gengsheng
    APPLIED THERMAL ENGINEERING, 2015, 84 : 74 - 81
  • [36] Analysis of Boiler Operational Variables Prior to Tube Leakage Fault by Artificial Intelligent System
    Al-Kayiem, Hussain H.
    Al-Naimi, Firas B. I.
    Amat, Wan N. Bt Wan
    ICPER 2014 - 4TH INTERNATIONAL CONFERENCE ON PRODUCTION, ENERGY AND RELIABILITY, 2014, 13
  • [37] An experimental study of monitoring internal leakage in water hydraulic cylinders using acoustic emission
    Chen, P
    Chua, PSK
    Lim, GH
    JOURNAL OF TESTING AND EVALUATION, 2005, 33 (06) : 445 - 451
  • [38] ACOUSTIC EMISSION DETECTION AND SIGNAL SOURCE ANALYSIS OF BOILER WATER WALL TUBE
    Yuan, Yilin
    Shen, Gongtian
    Shen, Yongna
    Zhang, Wenjun
    Wan, Qiang
    PROCEEDINGS OF ASME 2021 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION (IMECE2021), VOL 13, 2021,
  • [39] By using the neural network, monitoring and diagnosing air-leakage of a boiler system
    Wang, Guang-Jun
    Chen, Hong
    He, Zu-Wei
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2002, 22 (11): : 141 - 145
  • [40] DEVELOPMENT OF A MONITORING-SYSTEM FOR ASH DEPOSITS ON BOILER TUBE SURFACES
    CHAMBERS, AK
    WYNNYCKYJ, JR
    RHODES, E
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1981, 59 (02): : 230 - 235