MR temperature measurement in liver tissue at 0.23 T with a steady-state free precession sequence

被引:30
|
作者
Germain, D
Vahala, E
Ehnholm, GJ
Vaara, T
Ylihautala, M
Savart, M
Laurent, A
Tanttu, J
Saint-Jalmes, H
机构
[1] Ctr Res Intervent Imaging, Jouy En Josas, France
[2] Marconi Med Syst France, Chatenay Malabry, France
[3] Marconi Med Syst Finland, Vantaa, Finland
[4] Univ Lyon 1, Lab RMN, F-69365 Lyon, France
关键词
temperature; interventional MRI; SSFP sequence; liver tumors; thermoblation;
D O I
10.1002/mrm.10147
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
MRI can be used for monitoring temperature during a thermocoagulation treatment of tumors. The aim of this study was to demonstrate the suitability of a 3D steady-state free precession sequence (3D Fast Imaging with Steady-State Precession, 3D TrueFISP) for MR temperature measurement at 0.23 T, and to compare it to the spin-echo (SE) and spoiled 3D gradient-echo (3D GRE) sequences. The optimal flip angle for the TrueFISP sequence was calculated for the best temperature sensitivity in the image signal from liver tissue, and verified from the images acquired during the thermocoagulation of excised pig liver. Factors influencing the accuracy of the measured temperatures Eire discussed. The TrueFISP results are compared to the calculated values of optimized SE and 3D GRE sequences. The accuracy of TrueFISP in the liver at 0.23 T, in imaging conditions used during thermocoagulation procedures, is estimated to be +/-3.3degreesC for a voxel of 2.5 x 2.5 x 6 mm(3) and acquisition time of 18 s. For the SE and GRE sequences, with similar resolution and somewhat longer imaging time, the uncertainty in the temperature is estimated to be larger by a factor of 2 and 1.2, respectively. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:940 / 947
页数:8
相关论文
共 50 条
  • [31] Flow artifacts in steady-state free precession cine imaging
    Storey, P
    Li, W
    Chen, Q
    Edelman, RR
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (01) : 115 - 122
  • [32] Dark flow artifacts with steady-state free precession cine MR technique: Causes and implications for cardiac MR imaging
    Li, W
    Storey, P
    Chen, Q
    Li, BSY
    Prasad, PV
    Edelman, RR
    RADIOLOGY, 2004, 230 (02) : 569 - 575
  • [33] FMRI using balanced steady-state free precession (SSFP)
    Miller, Karla L.
    NEUROIMAGE, 2012, 62 (02) : 713 - 719
  • [34] MOTION-INSENSITIVE, STEADY-STATE FREE PRECESSION IMAGING
    ZUR, Y
    WOOD, ML
    NEURINGER, LJ
    MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (03) : 444 - 459
  • [35] Frequency-modulated steady-state free precession imaging
    Foxall, DL
    MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (03) : 502 - 508
  • [36] Forward Modeling Steady-State Free Precession in Surface NMR
    Griffiths, Matthew P.
    Grombacher, Denys
    Liu, Lichao
    Vang, Mathias O.
    Larsen, Jakob Juul
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2022, 60
  • [37] Phase contrast using multiecho steady-state free precession
    Pai, Vinay M.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (02) : 419 - 424
  • [38] Flow sensitivity and coherence in steady-state free spin precession
    Azeredo, RBD
    Engelsberg, M
    Colnago, LA
    PHYSICAL REVIEW E, 2001, 64 (01):
  • [39] VISIBILITY OF EPIDERMOID TUMORS ON STEADY-STATE FREE PRECESSION IMAGES
    SAKAMOTO, Y
    TAKAHASHI, M
    USHIO, Y
    KOROGI, Y
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1994, 15 (09) : 1737 - 1744
  • [40] STEADY-STATE FREE PRECESSION IMAGING OF THE INNER-EAR
    STILLMAN, AE
    REMLEY, K
    LOES, DJ
    HU, XP
    LATCHAW, RE
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1994, 15 (02) : 348 - 350