MR temperature measurement in liver tissue at 0.23 T with a steady-state free precession sequence

被引:30
|
作者
Germain, D
Vahala, E
Ehnholm, GJ
Vaara, T
Ylihautala, M
Savart, M
Laurent, A
Tanttu, J
Saint-Jalmes, H
机构
[1] Ctr Res Intervent Imaging, Jouy En Josas, France
[2] Marconi Med Syst France, Chatenay Malabry, France
[3] Marconi Med Syst Finland, Vantaa, Finland
[4] Univ Lyon 1, Lab RMN, F-69365 Lyon, France
关键词
temperature; interventional MRI; SSFP sequence; liver tumors; thermoblation;
D O I
10.1002/mrm.10147
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
MRI can be used for monitoring temperature during a thermocoagulation treatment of tumors. The aim of this study was to demonstrate the suitability of a 3D steady-state free precession sequence (3D Fast Imaging with Steady-State Precession, 3D TrueFISP) for MR temperature measurement at 0.23 T, and to compare it to the spin-echo (SE) and spoiled 3D gradient-echo (3D GRE) sequences. The optimal flip angle for the TrueFISP sequence was calculated for the best temperature sensitivity in the image signal from liver tissue, and verified from the images acquired during the thermocoagulation of excised pig liver. Factors influencing the accuracy of the measured temperatures Eire discussed. The TrueFISP results are compared to the calculated values of optimized SE and 3D GRE sequences. The accuracy of TrueFISP in the liver at 0.23 T, in imaging conditions used during thermocoagulation procedures, is estimated to be +/-3.3degreesC for a voxel of 2.5 x 2.5 x 6 mm(3) and acquisition time of 18 s. For the SE and GRE sequences, with similar resolution and somewhat longer imaging time, the uncertainty in the temperature is estimated to be larger by a factor of 2 and 1.2, respectively. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:940 / 947
页数:8
相关论文
共 50 条
  • [21] Characterizing chronic pericarditis using steady-state free-precession cine MR imaging
    Kovanlikaya, A
    Burke, LP
    Nelson, MD
    Wood, J
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (02) : 475 - 476
  • [22] GRADIENT MOMENT NULLING FOR STEADY-STATE FREE PRECESSION MR IMAGING OF CEREBROSPINAL-FLUID
    WOOD, ML
    ZUR, Y
    NEURINGER, LJ
    MEDICAL PHYSICS, 1991, 18 (05) : 1038 - 1044
  • [23] Renal arteries: Comparison of steady-state free precession MR angiography and contrast-enhanced MR angiography
    Herborn, CU
    Watkins, DM
    Runge, VM
    Gendron, JM
    Montgomery, ML
    Naul, LG
    RADIOLOGY, 2006, 239 (01) : 263 - 268
  • [24] T2-WEIGHTED BREATH-HOLD MR-IMAGING OF THE LIVER AT 1.5-T - RESULTS WITH A 3-DIMENSIONAL STEADY-STATE FREE PRECESSION SEQUENCE IN 87 PATIENTS
    TAUPITZ, M
    SPEIDEL, A
    HAMM, B
    DEIMLING, M
    REICHEL, M
    BOCK, A
    WOLF, KJ
    RADIOLOGY, 1995, 194 (02) : 439 - 446
  • [25] Unenhanced MR angiography of the renal arteries with balanced steady-state free precession Dixon method
    Stafford, Randall B.
    Sabati, Mohammad
    Haakstad, Michael J.
    Mahallati, Houman
    Frayne, Richard
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (01) : 243 - 246
  • [26] A NEW METHOD OF MEASURING T2 USING STEADY-STATE FREE PRECESSION
    MATSUI, S
    KURODA, M
    KOHNO, H
    JOURNAL OF MAGNETIC RESONANCE, 1985, 62 (01) : 12 - 18
  • [27] Noncontrast MRI Surveillance of Craniopharyngiomas Using a Balanced Steady-state Free Precession (bSSFP) Sequence
    Trinh, Kelly
    Tang, Michael
    White-Dzuro, Claire
    Lang, Min
    Buch, Karen
    Rincon, Sandra
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2025, 46 (01) : 136 - 140
  • [28] Modifications of the steady-state free-precession sequence for the detection of pure nuclear quadrupole resonance
    Rudakov, TN
    Belyakov, AV
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1998, 31 (10) : 1251 - 1256
  • [29] Enhanced spectral shaping in steady-state free precession imaging
    Cukur, Tolga
    Bangerter, Neal K.
    Nishimura, Dwight G.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (06) : 1216 - 1223
  • [30] Spiral balanced steady-state free precession cardiac imaging
    Nayak, KS
    Hargreaves, BA
    Hu, BS
    Nishimura, DG
    Pauly, JM
    Meyer, CH
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (06) : 1468 - 1473