Stroke Volume Variation for Prediction of Fluid Responsiveness in Patients Undergoing Gastrointestinal Surgery

被引:30
|
作者
Li, Cheng [1 ]
Lin, Fu-qing [1 ]
Fu, Shu-kun [1 ]
Chen, Guo-qiang [1 ]
Yang, Xiao-hu [1 ]
Zhu, Chun-yan [1 ]
Zhang, Li-jun [2 ]
Li, Quan [1 ]
机构
[1] Tongji Univ, Sch Med, Dept Anesthesiol, Shanghai Peoples Hosp 10, Shanghai 200092, Peoples R China
[2] PLA, Hosp 187, Dept Anesthesiol, Haikou, Peoples R China
来源
关键词
Stroke volume variation; tidal volume; Functional haemodynamic; Fluid balance; Gastrointestinal surgery; MECHANICALLY VENTILATED PATIENTS; PULSE CONTOUR ANALYSIS; CARDIAC-OUTPUT MEASUREMENTS; PULMONARY-ARTERY CATHETER; PRESSURE VARIATION; MONITORING-SYSTEM; SEPTIC SHOCK; TIDAL VOLUME; WAVE-FORM; FLOTRAC(TM);
D O I
10.7150/ijms.5293
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Stroke volume variation (SVV) has been shown to be a reliable predictor of fluid responsiveness. However, the predictive role of SVV measured by FloTrac/Vigileo system in prediction of fluid responsiveness was unproven in patients undergoing ventilation with low tidal volume. Methods: Fifty patients undergoing elective gastrointestinal surgery were randomly divided into two groups: Group C [n(1) = 20, tidal volume (V-t) = 8 ml/kg, frequency (F) = 12/min] and Group L [n(2) = 30, V-t = 6 ml/kg, F = 16/min]. After anesthesia induction, 6% hydroxyethyl starch130/0.4 solution (7 ml/kg) was intravenously transfused. Besides standard haemodynamic monitoring, SVV, cardiac output, cardiac index (CI), stroke volume (SV), stroke volume index (SVI), systemic vascular resistance (SVR) and systemic vascular resistance index (SVRI) were determined with the FloTrac/Vigileo system before and after fluid loading. Results: After fluid loading, the MAP, CVP, SVI and CI increased significantly, whereas the SVV and SVR decreased markedly in both groups. SVI was significantly correlated to the SVV, CVP but not the HR, MAP and SVR. SVI was significantly correlated to the SVV before fluid loading (Group C: r = 0.909; Group L: r = 0.758) but not the HR, MAP, CVP and SVR before fluid loading. The largest area under the ROC curve (AUC) was found for SVV (Group C, 0.852; Group L, 0.814), and the AUC for other preloading indices in two groups ranged from 0.324 to 0.460. Conclusion: SVV measured by FloTrac/Vigileo system can predict fluid responsiveness in patients undergoing ventilation with low tidal volumes during gastrointestinal surgery.
引用
收藏
页码:148 / 155
页数:8
相关论文
共 50 条
  • [41] The value of pulse pressure and stroke volume variation as predictors of fluid responsiveness during open chest surgery
    Wyffels, P. A. H.
    Sergeant, P.
    Wouters, P. F.
    ANAESTHESIA, 2010, 65 (07) : 704 - 709
  • [42] Comparative evaluation of stroke volume variation and inferior vena cava distensibility index for prediction of fluid responsiveness in mechanically ventilated patients
    Kaur, Kaminder Bir
    Nakra, Monish
    Mangal, Vishal
    Singh, Shalendra
    Taank, Priya
    Marwah, Vikas
    ANNALS OF CARDIAC ANAESTHESIA, 2021, 24 (03) : 327 - 332
  • [43] STROKE VOLUME VARIATION IS A GOOD PREDICTOR OF FLUID RESPONSIVENESS IN CARDIAC SURGERY PATIENTS WITH IMPLANTED INTRA-AORTIC BALLOON PUMP
    Enev, Rostislav
    Abedinov, Fillip
    Bakalova, Neda
    Atanasova, Margarita
    Chilingirova, Nezabravka
    Krastev, Plamen
    COMPTES RENDUS DE L ACADEMIE BULGARE DES SCIENCES, 2023, 76 (04): : 612 - 621
  • [44] Stroke volume variation fail to predict fluid responsiveness in patients undergoing pulmonary lobectomy with one-lung ventilation using thoracotomy
    Fu, Qiang
    Zhao, Feng
    Mi, Weidong
    Zhang, Hong
    BIOSCIENCE TRENDS, 2014, 8 (01) : 59 - 63
  • [45] Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation
    Biais, M.
    Nouette-Gaulain, K.
    Cottenceau, V.
    Revel, P.
    Sztark, F.
    BRITISH JOURNAL OF ANAESTHESIA, 2008, 101 (06) : 761 - 768
  • [46] Predicting fluid responsiveness with stroke volume variation despite multiple extrasystoles
    Cannesson, Maxime
    Nam Phuong Tran
    Cho, Max
    Hatib, Feras
    Michard, Frederic
    CRITICAL CARE MEDICINE, 2012, 40 (01) : 193 - 198
  • [47] Prone position affects stroke volume variation performance in predicting fluid responsiveness in neurosurgical patients
    Berger, K.
    Francony, G.
    Bouzat, P.
    Halle, C.
    Genty, C.
    Oddoux, M.
    Gay, E.
    Albaladejo, P.
    Payen, J. -F.
    MINERVA ANESTESIOLOGICA, 2015, 81 (06) : 628 - 635
  • [48] PULSE PRESSURE AND STROKE VOLUME VARIATION ARE GOOD PREDICTORS OF FLUID RESPONSIVENESS IN SEVERE SEPSIS PATIENTS
    Drvar, Z.
    Baronica, R.
    Tomasevic, B.
    Pavlek, M.
    Miric, M.
    Peric, M.
    INTENSIVE CARE MEDICINE, 2012, 38 : S202 - S202
  • [49] Effect of pulse pressure on the predictability of stroke volume variation for fluid responsiveness in patients with coronary disease
    Kim, So Yeon
    Song, Young
    Shim, Jae Kwang
    Kwak, Young Lan
    JOURNAL OF CRITICAL CARE, 2013, 28 (03) : 318.e1 - 318.e7
  • [50] Prediction of fluid responsiveness in septic shock patients: comparing automated pulse pressure variation by IntelliVue MP monitor and stroke volume variation by FloTrac™/Vigileo™
    B Khwannimit
    R Bhurayanontachai
    Critical Care, 15 (Suppl 1):