Stroke Volume Variation for Prediction of Fluid Responsiveness in Patients Undergoing Gastrointestinal Surgery

被引:30
|
作者
Li, Cheng [1 ]
Lin, Fu-qing [1 ]
Fu, Shu-kun [1 ]
Chen, Guo-qiang [1 ]
Yang, Xiao-hu [1 ]
Zhu, Chun-yan [1 ]
Zhang, Li-jun [2 ]
Li, Quan [1 ]
机构
[1] Tongji Univ, Sch Med, Dept Anesthesiol, Shanghai Peoples Hosp 10, Shanghai 200092, Peoples R China
[2] PLA, Hosp 187, Dept Anesthesiol, Haikou, Peoples R China
来源
关键词
Stroke volume variation; tidal volume; Functional haemodynamic; Fluid balance; Gastrointestinal surgery; MECHANICALLY VENTILATED PATIENTS; PULSE CONTOUR ANALYSIS; CARDIAC-OUTPUT MEASUREMENTS; PULMONARY-ARTERY CATHETER; PRESSURE VARIATION; MONITORING-SYSTEM; SEPTIC SHOCK; TIDAL VOLUME; WAVE-FORM; FLOTRAC(TM);
D O I
10.7150/ijms.5293
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Stroke volume variation (SVV) has been shown to be a reliable predictor of fluid responsiveness. However, the predictive role of SVV measured by FloTrac/Vigileo system in prediction of fluid responsiveness was unproven in patients undergoing ventilation with low tidal volume. Methods: Fifty patients undergoing elective gastrointestinal surgery were randomly divided into two groups: Group C [n(1) = 20, tidal volume (V-t) = 8 ml/kg, frequency (F) = 12/min] and Group L [n(2) = 30, V-t = 6 ml/kg, F = 16/min]. After anesthesia induction, 6% hydroxyethyl starch130/0.4 solution (7 ml/kg) was intravenously transfused. Besides standard haemodynamic monitoring, SVV, cardiac output, cardiac index (CI), stroke volume (SV), stroke volume index (SVI), systemic vascular resistance (SVR) and systemic vascular resistance index (SVRI) were determined with the FloTrac/Vigileo system before and after fluid loading. Results: After fluid loading, the MAP, CVP, SVI and CI increased significantly, whereas the SVV and SVR decreased markedly in both groups. SVI was significantly correlated to the SVV, CVP but not the HR, MAP and SVR. SVI was significantly correlated to the SVV before fluid loading (Group C: r = 0.909; Group L: r = 0.758) but not the HR, MAP, CVP and SVR before fluid loading. The largest area under the ROC curve (AUC) was found for SVV (Group C, 0.852; Group L, 0.814), and the AUC for other preloading indices in two groups ranged from 0.324 to 0.460. Conclusion: SVV measured by FloTrac/Vigileo system can predict fluid responsiveness in patients undergoing ventilation with low tidal volumes during gastrointestinal surgery.
引用
收藏
页码:148 / 155
页数:8
相关论文
共 50 条
  • [21] Stroke Volume Variation as a Guide to Fluid Administration in Morbidly Obese Patients Undergoing Laparoscopic Bariatric Surgery
    Jain, Anil Kumar
    Dutta, Amitabh
    OBESITY SURGERY, 2010, 20 (06) : 709 - 715
  • [22] Pressure controlled ventilation on stroke volume variation as a predictor of fluid responsiveness in patients
    Ye, Weiguang
    Wang, Bin
    Wei, Limin
    Wang, Tianlong
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (06): : 10963 - 10970
  • [23] Prediction of fluid responsiveness in septic shock patients: comparing stroke volume variation by FloTrac/Vigileo and automated pulse pressure variation
    Khwannimit, Bodin
    Bhurayanontachai, Rungsun
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2012, 29 (02) : 64 - 69
  • [24] Stroke volume variation compared with pulse pressure variation and cardiac index changes for prediction of fluid responsiveness in mechanically ventilated patients
    Soliman, Randa Aly
    Samir, Shereif
    el Naggar, Ayman
    El Dehely, Khalaf
    EGYPTIAN JOURNAL OF CRITICAL CARE MEDICINE, 2015, 3 (01): : 9 - 16
  • [25] Evaluation of stroke volume variation and pulse pressure variation as predictors of fluid responsiveness in patients undergoing protective one-lung ventilation
    Fu, Qiang
    Duan, Mingda
    Zhao, Feng
    Mi, Weidong
    DRUG DISCOVERIES AND THERAPEUTICS, 2015, 9 (04): : 296 - 302
  • [26] Predictive values of pulse pressure variation and stroke volume variation for fluid responsiveness in patients with pneumoperitoneum
    Zlicar, Marko
    Novak-Jankovic, Vesna
    Blagus, Rok
    Cecconi, Maurizio
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2018, 32 (05) : 825 - 832
  • [27] Predictive values of pulse pressure variation and stroke volume variation for fluid responsiveness in patients with pneumoperitoneum
    Marko Zlicar
    Vesna Novak-Jankovic
    Rok Blagus
    Maurizio Cecconi
    Journal of Clinical Monitoring and Computing, 2018, 32 : 825 - 832
  • [28] Assessment of stroke volume variation for prediction of fluid responsiveness using the modified FloTrac™ and PiCCOplus™ system
    Hofer, Christoph K.
    Senn, Alban
    Weibel, Luc
    Zollinger, Andreas
    CRITICAL CARE, 2008, 12 (03):
  • [29] Assessment of stroke volume variation for prediction of fluid responsiveness using the modified FloTrac™ and PiCCOplus™ system
    Christoph K Hofer
    Alban Senn
    Luc Weibel
    Andreas Zollinger
    Critical Care, 12