18k Channels single photon counting readout circuit for hybrid pixel detector

被引:53
|
作者
Maj, P. [1 ]
Grybos, P. [1 ]
Szczygiel, R. [1 ]
Zoladz, M. [1 ]
Sakumura, T. [2 ]
Tsuji, Y. [2 ]
机构
[1] AGH Univ Sci & Technol, Dept Measurements & Elect, PL-30059 Krakow, Poland
[2] Rigaku Corp, Xray Anal Div, Akishima, Tokyo 1968666, Japan
关键词
PXD18k; Hybrid Pixel Detector; Single Photon Counting; CHIP; PROTOTYPE; WORKING; DESIGN; NOISE; MODE;
D O I
10.1016/j.nima.2012.08.103
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have performed measurements of an integrated circuit named PXD18k designed for hybrid pixel semiconductor detectors used in X-ray imaging applications. The PXD18k integrated circuit, fabricated in CMOS 180 nm technology, has dimensions of 9.64 mm x 20 mm and contains approximately 26 million transistors. The core of the IC is a matrix of 96 x 192 pixels with 100 mu m x 100 um pixel size. Each pixel works in a single photon counting mode. A single pixel contains two charge sensitive amplifiers with Krummenacher feedback scheme, two shapers, two discriminators (with independent thresholds A and B) and two 16-bit ripple counters. The data are read out via eight low voltage differential signaling (LVDS) outputs with 100 Mbps rate. The power consumption is dominated by analog blocks and it is about 23 mu W/pixel. The effective peaking time at the discriminator input is 30 ns and is mainly determined by the time constants of the charge sensitive amplifier (CSA). The gain is equal to 42.5 mu V/e(-) and the equivalent noise charge is 168 e(-) rms (with bump-bonded silicon pixel detector). Thanks to the use of trim DACs in each pixel, the effective threshold spread at the discriminator input is only 1.79 mV. The dead time of the front end electronics for a standard setting is 172 ns (paralyzable model). In the standard readout mode (when the data collection time is separated from the time necessary to readout data from the chip) the PXD18k IC works with two energy thresholds per pixel. The PXD18k can also be operated in the continuous readout mode (with a zero dead time) where one can select the number of bits readout from each pixel to optimize the PXD18k frame rate. For example, for reading out 16 bits/pixel the frame rate is 2.7 kHz and for 4 bits/pixel it rises to 7.1 kHz. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:32 / 39
页数:8
相关论文
共 50 条
  • [1] Testability Features of a Single Photon Counting Hybrid Pixel Detector Readout Circuit with Charge Sharing Elimination Algorithm
    Maj, P.
    [J]. 2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [2] The hybrid pixel single photon counting detector XPAD
    Hustache-Ottini, S.
    Berar, J. -F.
    Boudet, N.
    Basolo, S.
    Bordessoule, M.
    Breugnon, P.
    Caillot, B.
    Clemens, J. -C.
    Delpierre, P.
    Dinkespiler, B.
    Koudobine, I.
    Medjoubi, K.
    Meessen, C.
    Menouni, M.
    Morel, C.
    Pangaud, P.
    Vigeolas, E.
    [J]. SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 1087 - +
  • [3] PXD18k-Fast Single Photon Counting Chip with Energy Window for Hybrid Pixel Detector
    Szczygiel, R.
    Grybos, P.
    Maj, P.
    Zoladz, M.
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 932 - 937
  • [4] Single Photon Counting Integrated Circuit Operating with CdTe Pixel Detector
    Maj, Piotr
    Grybos, Pawel
    Kmon, Piotr
    Szczygiel, Robert
    [J]. PROCEEDINGS OF THE 24TH INTERNATIONAL CONFERENCE MIXED DESIGN OF INTEGRATED CIRCUITS AND SYSTEMS - MIXDES 2017, 2017, : 324 - 327
  • [5] Characterisation of a single photon counting pixel detector
    Passmore, MS
    Bates, R
    Mathieson, K
    O'Shea, V
    Rahman, M
    Seller, P
    Smith, KM
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 466 (01): : 202 - 208
  • [6] High rate proton detection with single photon counting hybrid pixel detector
    Koziol, Anna
    Apresyan, Artur
    Grybos, Pawel
    Heller, Ryan
    Maj, Piotr
    Hussain, Mohd Meraj
    Szczygiel, Robert
    Xie, Si
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 956
  • [7] Multi-Energy, Fast Counting Hybrid CZT Pixel Detector with Dedicated Readout Integrated Circuit
    Clajus, Martin
    Cajipe, Victoria B.
    Hayakawa, Satoshi
    Tuemer, Tuemay O.
    Willson, Paul D.
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3602 - 3606
  • [8] A multispectral analog photon-counting readout circuit for X-ray hybrid pixel detectors
    Perenzoni, Matteo
    Stoppa, David
    Malfatti, Mattia
    Simoni, Andrea
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2008, 57 (07) : 1438 - 1444
  • [9] The Study of Calibration for the Hybrid Pixel Detector With Single Photon Counting in HEPS-BPIX
    Ding, Ye
    Li, Zhenjie
    Wei, Wei
    Zhang, Jie
    Li, Hangxu
    Zhang, Yan
    Ji, Xiaolu
    Li, Qiuju
    Sheng, Weifan
    Liu, Peng
    Chen, Yuanbai
    Zhu, Kejun
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2021, 68 (08) : 2088 - 2095
  • [10] Medipix3: A 64 k pixel detector readout chip working in single photon counting mode with improved spectrometric performance
    Ballabriga, R.
    Campbell, M.
    Heijne, E.
    Llopart, X.
    Tlustos, L.
    Wong, W.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 633 : S15 - S18