Imaging Cherenkov emission for quality assurance of high-dose-rate brachytherapy

被引:13
|
作者
Yogo, Katsunori [1 ,2 ]
Matsushita, Akihiro [2 ]
Tatsuno, Yuya [2 ]
Shimo, Takahiro [3 ]
Hirota, Seiko [4 ]
Nozawa, Marika [5 ]
Ozawa, Shuichi [6 ,7 ]
Ishiyama, Hiromichi [2 ,5 ]
Yasuda, Hiroshi [4 ]
Nagata, Yasushi [6 ,7 ]
Hayakawa, Kazushige [2 ,5 ]
机构
[1] Nagoya Univ, Grad Sch Med, Higashi Ku, 1-1-20 Daiko Minami, Nagoya, Aichi 4618673, Japan
[2] Kitasato Univ, Grad Sch Med Sci, Minami Ku, 1-15-1 Kitasato, Sagamihara, Kanagawa 2520373, Japan
[3] Tokyo Nishi Tokushukai Hosp, Dept Radiol, 3-1-1 Matsubara Cho, Akishima, Tokyo 1960003, Japan
[4] Hiroshima Univ, Res Inst Radiat Biol & Med, Dept Radiat Biophys, Minami Ku, Kasumi 1-2-3, Hiroshima 7348553, Japan
[5] Kitasato Univ, Sch Med, Minami Ku, 1-15-1 Kitasato, Sagamihara, Kanagawa 2520373, Japan
[6] Hiroshima High Precis Radiotherapy Canc Ctr, Higashi Ku, 3-2-2 Futabanosato, Hiroshima 7320057, Japan
[7] Hiroshima Univ Hosp, Dept Radiat Oncol, Minami Ku, 1-2-3 Kasumi, Hiroshima 7348551, Japan
基金
日本学术振兴会;
关键词
INTERSTITIAL BRACHYTHERAPY; CERENKOV EMISSION; SOURCE POSITION; PHOTON BEAMS; RATE IR-192; DOSIMETRY; THERAPY; OPTIMIZATION; TOMOGRAPHY; ANATOMY;
D O I
10.1038/s41598-020-60519-z
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
With advances in high-dose-rate (HDR) brachytherapy, the importance of quality assurance (QA) is increasing to ensure safe delivery of the treatment by measuring dose distribution and positioning the source with much closer intervals for highly active sources. However, conventional QA is time-consuming, involving the use of several different measurement tools. Here, we developed simple QA method for HDR brachytherapy based on the imaging of Cherenkov emission and evaluated its performance. Light emission from pure water irradiated by an Ir-192 gamma-ray source was captured using a charge-coupled device camera. Monte Carlo calculations showed that the observed light was primarily Cherenkov emissions produced by Compton-scattered electrons from the gamma-rays. The uncorrected Cherenkov light distribution, which was 5% on average except near the source (within 7 mm from the centre), agreed with the dose distribution calculated using the treatment planning system. The accuracy was attributed to isotropic radiation and short-range Compton electrons. The source positional interval, as measured from the light images, was comparable to the expected intervals, yielding spatial resolution similar to that permitted by conventional film measurements. The method should be highly suitable for quick and easy QA investigations of HDR brachytherapy as it allows simultaneous measurements of dose distribution, source strength, and source position using a single image.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Imaging Cherenkov emission for quality assurance of high-dose-rate brachytherapy
    Katsunori Yogo
    Akihiro Matsushita
    Yuya Tatsuno
    Takahiro Shimo
    Seiko Hirota
    Marika Nozawa
    Shuichi Ozawa
    Hiromichi Ishiyama
    Hiroshi Yasuda
    Yasushi Nagata
    Kazushige Hayakawa
    [J]. Scientific Reports, 10
  • [2] QUALITY ASSURANCE TOOL FOR HIGH-DOSE-RATE BRACHYTHERAPY
    DEWERD, LA
    JURSINIC, P
    KITCHEN, R
    THOMADSEN, BR
    [J]. MEDICAL PHYSICS, 1995, 22 (04) : 435 - 440
  • [3] A quality assurance tool for high-dose-rate brachytherapy
    Rickey, Daniel W.
    Sasaki, David
    Bews, Jeff
    [J]. MEDICAL PHYSICS, 2010, 37 (06) : 2525 - 2532
  • [4] QUALITY ASSURANCE PROGRAM FOR HIGH-DOSE-RATE BRACHYTHERAPY
    MOWER, HW
    COSTEY, GE
    LAWSON, BJ
    WRIGHT, KA
    [J]. RADIOLOGY, 1992, 185 : 273 - 273
  • [5] Source position measurement by Cherenkov emission imaging from applicators for high-dose-rate brachytherapy
    Yogo, Katsunori
    Noguchi, Yumiko
    Okudaira, Kuniyasu
    Nozawa, Marika
    Ishiyama, Hiromichi
    Okamoto, Hiroyuki
    Yasuda, Hiroshi
    Oguchi, Hiroshi
    Yamamoto, Seiichi
    [J]. MEDICAL PHYSICS, 2021, 48 (01) : 488 - 499
  • [6] Real-time tracking of source movement by Cherenkov emission imaging for high-dose-rate brachytherapy
    Yogo, K.
    Tatsuno, Y.
    Shimo, T.
    Noguchi, Y.
    Okudaira, K.
    Nozawa, M.
    Ishiyama, H.
    Yasuda, H.
    Oguchi, H.
    Yamamoto, S.
    [J]. JOURNAL OF INSTRUMENTATION, 2022, 17 (07):
  • [7] Quality assurance measurements for high-dose-rate brachytherapy without film
    Jursinic, Paul A.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (01): : 246 - 261
  • [8] Fluorescent screen for high-dose-rate (HDR) brachytherapy quality assurance
    Lightstone, AW
    [J]. MEDICAL DOSIMETRY, 2005, 30 (03) : 143 - 144
  • [9] Quality assurance of treatment plans for interstitial and intracavitary high-dose-rate brachytherapy
    Das, Rupak K.
    Bradley, Kristin A.
    Nelson, Ian A.
    Patel, Rakesh
    Thomadsen, Bruce R.
    [J]. BRACHYTHERAPY, 2006, 5 (01) : 56 - 60
  • [10] Automated multi-parameter high-dose-rate brachytherapy quality assurance via radioluminescence imaging
    Jia, Mengyu
    Kim, Tae Jin
    Yang, Yong
    Xing, Lei
    Jean, Paul De
    Grafil, Elliot
    Jenkins, Cesare H.
    Fahimian, Benjamin P.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (22):