Imaging Cherenkov emission for quality assurance of high-dose-rate brachytherapy

被引:13
|
作者
Yogo, Katsunori [1 ,2 ]
Matsushita, Akihiro [2 ]
Tatsuno, Yuya [2 ]
Shimo, Takahiro [3 ]
Hirota, Seiko [4 ]
Nozawa, Marika [5 ]
Ozawa, Shuichi [6 ,7 ]
Ishiyama, Hiromichi [2 ,5 ]
Yasuda, Hiroshi [4 ]
Nagata, Yasushi [6 ,7 ]
Hayakawa, Kazushige [2 ,5 ]
机构
[1] Nagoya Univ, Grad Sch Med, Higashi Ku, 1-1-20 Daiko Minami, Nagoya, Aichi 4618673, Japan
[2] Kitasato Univ, Grad Sch Med Sci, Minami Ku, 1-15-1 Kitasato, Sagamihara, Kanagawa 2520373, Japan
[3] Tokyo Nishi Tokushukai Hosp, Dept Radiol, 3-1-1 Matsubara Cho, Akishima, Tokyo 1960003, Japan
[4] Hiroshima Univ, Res Inst Radiat Biol & Med, Dept Radiat Biophys, Minami Ku, Kasumi 1-2-3, Hiroshima 7348553, Japan
[5] Kitasato Univ, Sch Med, Minami Ku, 1-15-1 Kitasato, Sagamihara, Kanagawa 2520373, Japan
[6] Hiroshima High Precis Radiotherapy Canc Ctr, Higashi Ku, 3-2-2 Futabanosato, Hiroshima 7320057, Japan
[7] Hiroshima Univ Hosp, Dept Radiat Oncol, Minami Ku, 1-2-3 Kasumi, Hiroshima 7348551, Japan
基金
日本学术振兴会;
关键词
INTERSTITIAL BRACHYTHERAPY; CERENKOV EMISSION; SOURCE POSITION; PHOTON BEAMS; RATE IR-192; DOSIMETRY; THERAPY; OPTIMIZATION; TOMOGRAPHY; ANATOMY;
D O I
10.1038/s41598-020-60519-z
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
With advances in high-dose-rate (HDR) brachytherapy, the importance of quality assurance (QA) is increasing to ensure safe delivery of the treatment by measuring dose distribution and positioning the source with much closer intervals for highly active sources. However, conventional QA is time-consuming, involving the use of several different measurement tools. Here, we developed simple QA method for HDR brachytherapy based on the imaging of Cherenkov emission and evaluated its performance. Light emission from pure water irradiated by an Ir-192 gamma-ray source was captured using a charge-coupled device camera. Monte Carlo calculations showed that the observed light was primarily Cherenkov emissions produced by Compton-scattered electrons from the gamma-rays. The uncorrected Cherenkov light distribution, which was 5% on average except near the source (within 7 mm from the centre), agreed with the dose distribution calculated using the treatment planning system. The accuracy was attributed to isotropic radiation and short-range Compton electrons. The source positional interval, as measured from the light images, was comparable to the expected intervals, yielding spatial resolution similar to that permitted by conventional film measurements. The method should be highly suitable for quick and easy QA investigations of HDR brachytherapy as it allows simultaneous measurements of dose distribution, source strength, and source position using a single image.
引用
下载
收藏
页数:10
相关论文
共 50 条
  • [21] High-Dose-Rate Prostate Brachytherapy Consistently Results in High Quality Dosimetry
    White, Evan C.
    Kamrava, Mitchell R.
    Demarco, John
    Park, Sang-June
    Wang, Pin-Chieh
    Kayode, Oluwatosin
    Steinberg, Michael L.
    Demanes, D. Jeffrey
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 85 (02): : 543 - 548
  • [22] Modern development of high-dose-rate brachytherapy
    Itami, Jun
    JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2020, 50 (05) : 490 - 501
  • [23] VERIFICATION OF HIGH-DOSE-RATE BRACHYTHERAPY PLANS
    MOWER, HW
    LO, TC
    GIRSHOVICH, L
    LAWSON, BJ
    COSTEY, GE
    RADIOLOGY, 1992, 185 : 129 - 130
  • [24] "Magic phantom" - a quality assurance system for high dose rate brachytherapy
    Espinoza, A.
    Petasecca, M.
    Fuduli, I.
    Howie, A.
    Corde, S.
    Bucci, J.
    Jackson, M.
    Lerch, M. L. F.
    Rosenfeld, A. B.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S139 - S140
  • [25] Feasibility Study of Patient-specific Quality Assurance System for High-dose-rate Brachytherapy in Patients with Cervical Cancer
    Lee, Boram
    Ahn, Sung Hwan
    Kim, Hyeyoung
    Han, Youngyih
    Huh, Seung Jae
    Kim, Jin Sung
    Kim, Dong Wook
    Sim, Jina
    Yoon, Myonggeun
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2016, 68 (08) : L1029 - L1036
  • [26] A Quality Assurance System with a Web Camera for High Dose Rate Brachytherapy
    Ueda, Y.
    Hirose, A.
    Oohira, S.
    Isono, M.
    Tsujii, K.
    Miyazaki, M.
    Kawaguchi, Y.
    Konishi, K.
    Teshima, T.
    MEDICAL PHYSICS, 2015, 42 (06) : 3346 - 3346
  • [27] Feasibility study of patient-specific quality assurance system for high-dose-rate brachytherapy in patients with cervical cancer
    Boram Lee
    Sung Hwan Ahn
    Hyeyoung Kim
    Youngyih Han
    Seung Jae Huh
    Jin Sung Kim
    Dong Wook Kim
    Jina Sim
    Myonggeun Yoon
    Journal of the Korean Physical Society, 2016, 68 : 1029 - 1036
  • [28] Quality of life after high-dose-rate brachytherapy monotherapy for prostate cancer
    Contreras, Jessika A.
    Wilder, Richard B.
    Mellon, Eric A.
    Strom, Tobin J.
    Fernandez, Daniel C.
    Biagioli, Matthew C.
    INTERNATIONAL BRAZ J UROL, 2015, 41 (01): : 40 - 45
  • [29] Low-dose-rate brachytherapy is superior to high-dose-rate brachytherapy for bladder cancer
    Pos, FJ
    Horenblas, S
    Lebesque, J
    Moonen, L
    Schneider, C
    Sminia, P
    Bartelink, H
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (03): : 696 - 705
  • [30] Characterization of Dose Distributions in High-Dose-Rate Surface Brachytherapy
    Buzurovic, I.
    Hansen, J.
    Bhagwat, M.
    O'Farrell, D.
    Damato, A.
    Friesen, S.
    Devlin, P.
    Cormack, R.
    MEDICAL PHYSICS, 2015, 42 (06) : 3369 - 3370