Diagnostics For The Optimization Of An 11 keV Inverse Compton Scattering X-ray Source

被引:0
|
作者
Chauchat, A. -S. [1 ]
Brasile, J. -P. [1 ]
Le Flanchec, V. [2 ]
Negre, J. -P. [2 ]
Binet, A. [2 ]
Ortega, J. -M. [3 ]
机构
[1] Thales Commun & Secur, 4 Ave Louvresses, F-92230 Gennevilliers, France
[2] CEA DAM DIF, F-91290 Arpajon, France
[3] LCP Univ Paris Sud, F-91405 Orsay, France
关键词
Linac; Laser; X-Rays; Imaging Plate; Inverse Compton Scattering;
D O I
10.1063/1.4802307
中图分类号
O59 [应用物理学];
学科分类号
摘要
In a scope of a collaboration between Thales Communications & Security and CEA DAM DIF, 11 keV X-rays were produced by inverse Compton scattering on the ELSA facility. In this type of experiment, X-ray observation lies in the use of accurate electron and laser beam interaction diagnostics and on fitted X-ray detectors. The low interaction probability between < 100 mu m width, 12 ps [rms] length electron and photon pulses requires careful optimization of pulse spatial and temporal covering. Another issue was to observe 11 keV X-rays in the ambient radioactive noise of the linear accelerator. For that, we use a very sensitive detection scheme based on radio luminescent screens.
引用
收藏
页码:138 / 143
页数:6
相关论文
共 50 条
  • [41] X-ray generation by inverse Compton scattering at the superconducting RF test facility
    Shimizu, Hirotaka
    Akemoto, Mitsuo
    Arai, Yasuo
    Araki, Sakae
    Aryshev, Alexander
    Fukuda, Masafumi
    Fukuda, Shigeki
    Haba, Junji
    Hara, Kazufumi
    Hayano, Hitoshi
    Higashi, Yasuo
    Honda, Yosuke
    Honma, Teruya
    Kako, Eiji
    Kojima, Yuji
    Kondo, Yoshinari
    Lekomtsev, Konstantin
    Matsumoto, Toshihiro
    Michizono, Shinichiro
    Miyoshi, Toshinobu
    Nakai, Hirotaka
    Nakajima, Hiromitsu
    Nakanishi, Kota
    Noguchi, Shuichi
    Okugi, Toshiyuki
    Sato, Masato
    Shevelev, Mikhail
    Shishido, Toshio
    Takenaka, Tateru
    Tsuchiya, Kiyosumi
    Urakawa, Junji
    Watanabe, Ken
    Yamaguchi, Seiya
    Yamamoto, Akira
    Yamamoto, Yasuchika
    Sakaue, Kazuyuki
    Hosoda, Seiichi
    Iijima, Hokuto
    Kuriki, Masao
    Tanaka, Ryuta
    Kuramoto, Ayaka
    Omet, Mathieu
    Takeda, Ayaki
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 772 : 26 - 33
  • [42] Investigation of X-ray harmonics of the polarized Inverse Compton Scattering experiment at UCLA
    Doyuran, A
    Williams, O
    England, RJ
    Joshi, C
    Lim, J
    Rosenzweig, JB
    Tochitsky, S
    Travish, G
    [J]. 2005 IEEE PARTICLE ACCELERATOR CONFERENCE (PAC), VOLS 1-4, 2005, : 1725 - 1727
  • [43] Study of Rayleigh to Compton scattering ratio for pharmaceutical ingredients at 8 keV to 32 keV X-ray energy
    Manjunath, A.
    Kerur, B. R.
    [J]. MATERIALS TODAY-PROCEEDINGS, 2016, 3 (10) : 4134 - 4139
  • [44] Energy-Dispersive X-ray Absorption Spectroscopy with an Inverse Compton Source
    Huang, Juanjuan
    Guenther, Benedikt
    Achterhold, Klaus
    Cui, Yi-tao
    Gleich, Bernhard
    Dierolf, Martin
    Pfeiffer, Franz
    [J]. SCIENTIFIC REPORTS, 2020, 10 (01)
  • [45] Energy-Dispersive X-ray Absorption Spectroscopy with an Inverse Compton Source
    Juanjuan Huang
    Benedikt Günther
    Klaus Achterhold
    Yi-tao Cui
    Bernhard Gleich
    Martin Dierolf
    Franz Pfeiffer
    [J]. Scientific Reports, 10
  • [46] Inverse Compton scattering X-ray source yield optimization with a laser path folding system inserted in a pre-existent RF linac
    Chaleil, A.
    Le Flanchec, V.
    Binet, A.
    Negre, J. P.
    Devaux, J. F.
    Jacob, V.
    Villerioux, M.
    Bayle, A.
    Balleyguier, P.
    Prazeres, R.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 840 : 113 - 120
  • [47] Compton scattering and its applications: The pleiades femtosecond x-ray source at LLNL
    Hartemann, FV
    Brown, WJ
    Anderson, SG
    Barty, CPJ
    Betts, SM
    Booth, R
    Crane, JK
    Cross, RR
    Fittinghoff, DN
    Gibson, DJ
    Kuba, J
    Rupp, B
    Tremaine, AM
    Springer, PT
    [J]. QUANTUM ASPECTS OF BEAM PHYSICS, 2004, : 49 - 62
  • [48] High repetition-rate inverse Compton scattering x-ray source driven by a free-electron laser
    Carlsten, B. E.
    Krawczyk, F. L.
    Lewellen, J. W.
    Marksteiner, Q. R.
    Nguyen, D. C.
    Yampolsky, N. A.
    [J]. JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 2014, 47 (23)
  • [49] Anomalous nonlinear X-ray Compton scattering
    Fuchs, Matthias
    Trigo, Mariano
    Chen, Jian
    Ghimire, Shambhu
    Shwartz, Sharon
    Kozina, Michael
    Jiang, Mason
    Henighan, Thomas
    Bray, Crystal
    Ndabashimiye, Georges
    Bucksbaum, Philip H.
    Feng, Yiping
    Herrmann, Sven
    Carini, Gabriella A.
    Pines, Jack
    Hart, Philip
    Kenney, Christopher
    Guillet, Serge
    Boutee, Sebastien
    Williams, Garth J.
    Messerschmidt, Marc
    Seibert, M. Marvin
    Moeller, Stefan
    Hastings, Jerome B.
    Reis, David A.
    [J]. NATURE PHYSICS, 2015, 11 (11) : 964 - 970
  • [50] X-RAY COMPTON PLASMON SCATTERING BY SOLIDS
    PIMPALE, A
    MANDE, C