Diagnostics For The Optimization Of An 11 keV Inverse Compton Scattering X-ray Source

被引:0
|
作者
Chauchat, A. -S. [1 ]
Brasile, J. -P. [1 ]
Le Flanchec, V. [2 ]
Negre, J. -P. [2 ]
Binet, A. [2 ]
Ortega, J. -M. [3 ]
机构
[1] Thales Commun & Secur, 4 Ave Louvresses, F-92230 Gennevilliers, France
[2] CEA DAM DIF, F-91290 Arpajon, France
[3] LCP Univ Paris Sud, F-91405 Orsay, France
关键词
Linac; Laser; X-Rays; Imaging Plate; Inverse Compton Scattering;
D O I
10.1063/1.4802307
中图分类号
O59 [应用物理学];
学科分类号
摘要
In a scope of a collaboration between Thales Communications & Security and CEA DAM DIF, 11 keV X-rays were produced by inverse Compton scattering on the ELSA facility. In this type of experiment, X-ray observation lies in the use of accurate electron and laser beam interaction diagnostics and on fitted X-ray detectors. The low interaction probability between < 100 mu m width, 12 ps [rms] length electron and photon pulses requires careful optimization of pulse spatial and temporal covering. Another issue was to observe 11 keV X-rays in the ambient radioactive noise of the linear accelerator. For that, we use a very sensitive detection scheme based on radio luminescent screens.
引用
收藏
页码:138 / 143
页数:6
相关论文
共 50 条
  • [31] Magnetic x-ray Compton scattering
    Carra, P
    Fabrizio, M
    Santoro, G
    Thole, BT
    [J]. PHYSICAL REVIEW B, 1996, 53 (10) : R5994 - R5997
  • [32] Characterization of a bright, tunable, ultrafast Compton scattering X-ray source
    Hartemann, FV
    Tremaine, AM
    Anderson, SG
    Barty, CPJ
    Betts, SM
    Booth, R
    Brown, WJ
    Crane, JK
    Cross, RR
    Gibson, DJ
    Fittinghoff, DN
    Kuba, J
    Le Sage, GP
    Slaughter, DR
    Wootton, AJ
    Hartouni, EP
    Springer, PT
    Rosenzweig, JB
    Kerman, AK
    [J]. LASER AND PARTICLE BEAMS, 2004, 22 (03) : 221 - 244
  • [33] Compact Compton scattering X-ray source for advanced cancer research
    Luhmann, NC
    Boggan, JE
    Caryotakis, G
    Hartemann, FV
    Heritage, JP
    Landahl, E
    Matthews, DL
    Norman, A
    Solberg, T
    Vlieks, A
    [J]. 2000 25TH INTERNATIONAL CONFERENCE ON INFRARED AND MILLIMETER WAVES CONFERENCE DIGEST, 2000, : 7 - 8
  • [34] X-RAY COMPTON SCATTERING FOR ALUMINUM
    WALKER, CB
    [J]. PHYSICAL REVIEW, 1956, 103 (03): : 558 - 561
  • [35] Magnetic x-ray Compton scattering
    [J]. Phys Rev B, 10 (R5994):
  • [36] X-ray Compton scattering tomography
    Webber, James
    [J]. INVERSE PROBLEMS IN SCIENCE AND ENGINEERING, 2016, 24 (08) : 1323 - 1346
  • [37] ERL-Based Laser-Compton Scattering X-Ray Source for X-Ray Imaging
    Kosuge, A.
    Akagi, T.
    Honda, Y.
    Araki, S.
    Urakawa, J.
    Terunuma, N.
    Nagai, R.
    Shizuma, T.
    Mori, M.
    Hajima, R.
    [J]. X-RAY LASERS 2016, 2018, 202 : 261 - 264
  • [38] Optimization of the Compact Gamma-ray Source Based on Inverse Compton Scattering Design
    Chen, Han
    Du, Yingchao
    Yan, Lixin
    Shi, Jiaru
    Huang, Wenhui
    Tang, Chuanxiang
    [J]. 2018 IEEE ADVANCED ACCELERATOR CONCEPTS WORKSHOP (AAC), 2018,
  • [39] Study of X-Ray harmonics of the polarized Inverse Compton Scattering experiment at UCLA
    Doyuran, A
    England, J
    Joshi, C
    Musumeci, P
    Rosenzweig, J
    Tochitsky, S
    Travish, G
    Williams, O
    [J]. ADVANCED ACCELERATOR CONCEPTS, 2004, 737 : 750 - 756
  • [40] Narrowband inverse Compton scattering x-ray sources at high laser intensities
    Seipt, D.
    Rykovanov, S. G.
    Surzhykov, A.
    Fritzsche, S.
    [J]. PHYSICAL REVIEW A, 2015, 91 (03):