Long-term precision of glomerular filtration rate measurements using Cr-51-EDTA plasma clearance

被引:33
|
作者
Blake, GM
Roe, D
Lazarus, CR
机构
[1] Department of Nuclear Medicine, Guy’s Hospital, London, SE1 9RT, St Thomas Street
关键词
D O I
10.1097/00006231-199708000-00012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The long-term precision of chromium-51 ethylenediamine tetraacetic acid (Cr-51-EDTA) measurements of glomerular filtration rate (GFR) was evaluated in a retrospective study of data obtained over a 12 year period. Each GFR measurement was derived from plasma samples taken at 2, 3 and 4 h following injection of 3 MBq Cr-51-EDTA. The records of 7507 patients were reviewed, from which 55 subjects were identified as having had studies on 10 or more occasions. The mean number of studies per patient was 12.9 (range 10-23) over a mean period of 9.4 years (range 4.3-11.8 years). Plots of GFR, clearance half-life, (T-1/2) and volume of distribution (V-D) were drawn for each patient and used to identify subjects showing linear changes with time that could be fitted using linear regression. Each residual was expressed as a percentage of the expected value calculated from the regression line and all the residuals combined to give histograms for GFR, T-1/2 and V-D. Each histogram was fitted with a normal distribution between the -3 S.D. and +3 S.D. limits using weighted least squares. Final results for the coefficient of variation were: GFR 9.8%, T-1/2 6.7%, V-D 9.4%. The precision errors were used to calculate the smallest statistically significant change measurable by the Cr-51-EDTA technique. With 10% significance and 80% power, the smallest measurable change was 30% for GFR and 20% for T-1/2. Unless there are clinical grounds for thinking that a patient's volume of distribution has changed, T-1/2 is the optimal parameter for identifying real changes in renal function.
引用
收藏
页码:776 / 784
页数:9
相关论文
共 50 条
  • [31] (SIMULTANEOUS CLEARANCE MEASUREMENTS WITH CR-51-EDTA, INULIN, HIPPURAN-125 AND PAH IN DOG
    SCHWARTZ.
    SCHOLZ, A
    BOTSCH, H
    ZENTRALBLATT FUR VETERINARMEDIZIN RIEHE A, 1972, 19 (03): : 193 - +
  • [32] An evaluation of the body surface area correction for 51Cr-EDTA measurements of glomerular filtration rate
    Blake, GM
    Grewal, GS
    NUCLEAR MEDICINE COMMUNICATIONS, 2005, 26 (05) : 447 - 451
  • [33] Validation of Glomerular Filtration Rate Calculation Using Cr-51 EDTA in the Obese Population
    Perry, L. M.
    Towey, D. J.
    Chuah, L.
    Miras, A.
    Faruq, S.
    Fenske, W.
    Le Roux, C. W.
    Meades, R. T.
    Svensson, W.
    Nijran, K. S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S577 - S577
  • [34] A software for automatic calculation of glomerular filtration rate with 51Cr-EDTA
    Gomez-Perales, J. L.
    Garcia-Mendoza, A.
    Valderas Montes, P.
    Furest Perez, J. A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S491 - S491
  • [35] Glomerular filtration rate (GFR) (51Cr-EDTA) in paediatric oncology
    De Miguel, B. Martinez
    Montalban, E. Martinez
    Herrero, S. Blanco
    Miguel, P. Garcia
    Almarza, G. Riesco
    Curto, L. Martin
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S336 - S336
  • [36] TOTAL PLASMA CLEARANCE OF NA(CR-51-EDTA) AN INULIN-C-14 IN RATS
    SEIDEL, A
    VOLF, V
    EXPERIENTIA, 1970, 26 (12): : 1325 - &
  • [37] Estimation of residual glomerular filtration rate in peritoneal dialysis patients using cystatin C: comparison with 51Cr-EDTA clearance
    Carter, Joanne L.
    Lane, Catherine E.
    Fan, Stanley L.
    Lamb, Edmund J.
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2011, 26 (11) : 3729 - 3732
  • [38] ROUTINE METHODS AND THEIR RELIABILITY FOR ASSESSMENT OF GLOMERULAR-FILTRATION RATE IN ADULTS - SPECIAL REFERENCE TO TOTAL CR-51 EDTA PLASMA CLEARANCE
    BROCHNERMORTENSEN, J
    DANISH MEDICAL BULLETIN, 1978, 25 (05) : 181 - 202
  • [39] CR-51-EDTA PLASMA-CLEARANCE IN SEVERE RENAL-FAILURE DETERMINED BY ONE PLASMA SAMPLE
    KAMPER, AL
    NIELSEN, SL
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1989, 49 (06): : 555 - 559
  • [40] GLOMERULAR FILTRATION RATE MEASUREMENT IN MAN BY SINGLE INJECTION METHOD USING 51CR-EDTA
    CHANTLER, C
    GARNETT, ES
    PARSONS, V
    VEALL, N
    CLINICAL SCIENCE, 1969, 37 (01) : 169 - &