Long-term precision of glomerular filtration rate measurements using Cr-51-EDTA plasma clearance

被引:33
|
作者
Blake, GM
Roe, D
Lazarus, CR
机构
[1] Department of Nuclear Medicine, Guy’s Hospital, London, SE1 9RT, St Thomas Street
关键词
D O I
10.1097/00006231-199708000-00012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The long-term precision of chromium-51 ethylenediamine tetraacetic acid (Cr-51-EDTA) measurements of glomerular filtration rate (GFR) was evaluated in a retrospective study of data obtained over a 12 year period. Each GFR measurement was derived from plasma samples taken at 2, 3 and 4 h following injection of 3 MBq Cr-51-EDTA. The records of 7507 patients were reviewed, from which 55 subjects were identified as having had studies on 10 or more occasions. The mean number of studies per patient was 12.9 (range 10-23) over a mean period of 9.4 years (range 4.3-11.8 years). Plots of GFR, clearance half-life, (T-1/2) and volume of distribution (V-D) were drawn for each patient and used to identify subjects showing linear changes with time that could be fitted using linear regression. Each residual was expressed as a percentage of the expected value calculated from the regression line and all the residuals combined to give histograms for GFR, T-1/2 and V-D. Each histogram was fitted with a normal distribution between the -3 S.D. and +3 S.D. limits using weighted least squares. Final results for the coefficient of variation were: GFR 9.8%, T-1/2 6.7%, V-D 9.4%. The precision errors were used to calculate the smallest statistically significant change measurable by the Cr-51-EDTA technique. With 10% significance and 80% power, the smallest measurable change was 30% for GFR and 20% for T-1/2. Unless there are clinical grounds for thinking that a patient's volume of distribution has changed, T-1/2 is the optimal parameter for identifying real changes in renal function.
引用
下载
收藏
页码:776 / 784
页数:9
相关论文
共 50 条
  • [21] MEASUREMENT OF GLOMERULAR-FILTRATION RATE BY SINGLE-INJECTION, SINGLE-SAMPLE TECHNIQUES, USING CR-51-EDTA OR IOHEXOL
    RYDSTROM, M
    TENGSTROM, B
    CEDERQUIST, I
    AHLMEN, J
    SCANDINAVIAN JOURNAL OF UROLOGY AND NEPHROLOGY, 1995, 29 (02): : 135 - 139
  • [22] COMPARISON OF GLOMERULAR FILTRATION RATE MEASUREMENTS USING INULIN, CR-51EDTA, AND A PHOSPHATE INFUSION TECHNIQUE
    STAMP, TCB
    STACEY, TE
    ROSE, GA
    CLINICA CHIMICA ACTA, 1970, 30 (02) : 351 - +
  • [23] Glomerular filtration rate: comparison of simultaneous plasma clearance of 99mTc-DTPA and 51Cr-EDTA revisited
    Simonsen, Jane A.
    Thilsing-Hansen, Kasper
    Hoilund-Carlsen, Poul F.
    Gerke, Oke
    Andersen, Thomas L.
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2020, 80 (05): : 408 - 411
  • [24] Time to complete mixing for the measurement of glomerular filtration rate from single bolus plasma 51Cr-EDTA clearance
    Bird, NJ
    Henderson, BL
    Lui, D
    Peters, M
    NUCLEAR MEDICINE COMMUNICATIONS, 2004, 25 (04) : 393 - 398
  • [25] ESTIMATION OF GLOMERULAR FILTRATION USING CR-51 EDTA
    FRANCOIS, B
    POZET, N
    RATTANACHANE, B
    TRAEGER, J
    NEPHRON, 1971, 8 (02) : 147 - +
  • [26] 68Ga-EDTA PET/CT Imaging and Plasma Clearance for Glomerular Filtration Rate Quantification: Comparison to Conventional 51Cr-EDTA
    Hofman, Michael
    Binns, David
    Johnston, Val
    Siva, Shankar
    Thompson, Mick
    Eu, Peter
    Collins, Marnie
    Hicks, Rodney J.
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03) : 405 - 409
  • [27] PRECISION OF 24-HOUR ENDOGENOUS CREATININE CLEARANCE AND TOTAL [CR-51] EDTA PLASMA CLEARANCE AS USED FOR ROUTINE DETERMINATION OF GLOMERULAR-FILTRATION RATE IN ADULT PATIENTS
    BROCHNERMORTENSEN, J
    RODBRO, P
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1975, 35 : 40 - 40
  • [29] Reference Values of Glomerular Filtration Rate Measurement by 51Cr-EDTA Clearance in Potential Kidney Donors
    Gil, I.
    Roca, M.
    Saldana, P.
    Valero, J.
    Maymo, S.
    Camacho, L.
    Notta, P.
    Noriega, E.
    Mora, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S576 - S576
  • [30] RAPID DECLINE OF GLOMERULAR FILTRATION RATE AFTER LIVER TRANSPLANTATION MEASURED BY CR-51-EDTA-CLEARANCE
    Hornum, Mads
    Penninga, Luit
    Rasmussen, Allan
    Plagborg, Ulla B.
    Oturai, Peter
    Feldt-Rasmussen, Bo
    Hillingso, Jens G.
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2014, 29 : 109 - 110