High-Resolution Maps of Magnetization Transfer with Inherent Correction for RF Inhomogeneity and T1 Relaxation Obtained from 3D FLASH MRI

被引:235
|
作者
Helms, Gunther [1 ]
Dathe, Henning [2 ]
Kallenberg, Kai [1 ,3 ]
Dechent, Peter [1 ]
机构
[1] Univ Med Gottingen, MR Forsch Neurol & Psychiat, D-37075 Gottingen, Germany
[2] AG Biomech, Abt Kieferorthopad, Gottingen, Germany
[3] Univ Med Gottingen, Abt Neuroradiol, Gottingen, Germany
关键词
magnetization transfer; relaxation; saturation; human brain; multiple sclerosis;
D O I
10.1002/mrm.21732
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
empirical equation for the magnetization transfer (MT) FLASH signal is derived by analogy to dual-excitation FLASH introducing a novel semiquantitative parameter for MT, the per centage saturation imposed by one MT pulse during TR. This parameter is obtained by a linear transformation of the inverse signal, using two reference experiments of proton density and T, weighting. The influence of sequence parameters on the MT saturation was studied. An 8.5-min protocol for brain imaging a 3 T was based on nonselective sagittal 3D-FLASH at 1.25 mm isotropic resolution using partial acquisition techniques (TRITE alpha = 25ms/4.9ms/5 degrees or 11 ms/4.9ms/15 degrees for the T-1 reference). 12.8 ms Gaussian MT pulse was applied 2.2 kHz off-resonance with 540 degrees flip angle. The MT saturation maps showed an excel lent contrast in the brain due to clearly separated distributiom for white and gray matter and cerebrospinal fluid. Within the limits of the approximation (excitation <15 degrees, TR/T-1 << 1) the MT term depends mainly on TR, the energy and offset of the MT pulse, but hardly on excitation and T, relaxation. It is inherently compensated for inhomogeneities of receive and transmit RF fields. The MT saturation appeared to be a sensitive parameter to depict MS lesions and alterations of normal-appearing white matter. Magn Reson Med 60:1396-1407, 2008. (C) 2008 Wiley Liss, Inc.
引用
收藏
页码:1396 / 1407
页数:12
相关论文
共 50 条
  • [41] A Novel Profile/View Ordering With a Non-Convex Star Shutter for High-Resolution 3D Volumetric T1 Mapping Under Multiple Breath-Holds
    Wang, Sui-Cheng
    Patel, Amit R.
    Tanaka, Akiko
    Wang, Hui
    Ota, Takeyoshi
    Lang, Roberto M.
    Carroll, Timothy J.
    Kawaji, Keigo
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (06) : 2215 - 2224
  • [42] Optimized 14+1 receive coil array and position system for 3D high-resolution MRI of dental and maxillomandibular structures
    Sedlacik, Jan
    Kutzner, Daniel
    Khokale, Arun
    Schulze, Dirk
    Fiehler, Jens
    Celik, Turgay
    Gareis, Daniel
    Smeets, Ralf
    Friedrich, Reinhard E.
    Heiland, Max
    Assaf, Alexandre T.
    DENTOMAXILLOFACIAL RADIOLOGY, 2016, 45 (01)
  • [43] Investigating the mechanical function of the cervix during pregnancy using finite element models derived from high-resolution 3D MRI
    Fernandez, M.
    House, M.
    Jambawalikar, S.
    Zork, N.
    Vink, J.
    Wapner, R.
    Myers, K.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2016, 19 (04) : 404 - 417
  • [44] Fast MR Imaging of the Paediatric Abdomen with CAIPIRINHA-Accelerated T1w 3D FLASH and with High-Resolution T2w HASTE: A Study on Image Quality
    Li, Mengxia
    Winkler, Beate
    Pabst, Thomas
    Bley, Thorsten
    Koestler, Herbert
    Neubauer, Henning
    GASTROENTEROLOGY RESEARCH AND PRACTICE, 2015, 2015
  • [45] Comparison of High Resolution Gradient Echo, XBONE T1, XBONE T2, Spin Echo T1 and 3D SST1 magnetic resonance imaging sequences for imagining the canine elbow
    Zhalniarovich, Y.
    Adamiak, Z.
    Glodek, J.
    Przyborowska, P.
    Holak, P.
    POLISH JOURNAL OF VETERINARY SCIENCES, 2014, 17 (04): : 587 - 591
  • [46] Articular cartilage grading of the knee: diagnostic performance of fat-suppressed 3D volume isotropic turbo spin-echo acquisition (VISTA) compared with 3D T1 high-resolution isovolumetric examination (THRIVE)
    Lee, Young Han
    Hahn, Seok
    Lim, Daekeon
    Suh, Jin-Suck
    ACTA RADIOLOGICA, 2017, 58 (02) : 190 - 196
  • [47] Fast and robust 3D T1 mapping using spiral encoding and steady RF excitation at 7T: application to cardiac manganese enhanced MRI (MEMRI) in mice
    Castets, Charles R.
    Ribot, Emeline J.
    Lefrancois, William
    Trotier, Aurelien J.
    Thiaudiere, Eric
    Franconi, Jean-Michel
    Miraux, Sylvain
    NMR IN BIOMEDICINE, 2015, 28 (07) : 881 - 889
  • [48] Magnetization-prepared 2 Rapid Gradient-Echo MRI for B1 Insensitive 3D T1 Mapping of Hip Cartilage: An Experimental and Clinical Validation
    Schmaranzer, Florian
    Afacan, Onur
    Lerch, Till D.
    Kim, Young-Jo
    Siebenrock, Klaus A.
    Ith, Michael
    Cullmann, Jennifer L.
    Kober, Tobias
    Klarhoefer, Markus
    Tannast, Moritz
    Bixby, Sarah D.
    Novais, Eduardo N.
    Jung, Bernd
    RADIOLOGY, 2021, 299 (01) : 150 - 158
  • [49] High-Resolution 3D versus Standard-Resolution 2D T2-Weighted Turbo Spin Echo MRI for the Assessment of Lumbar Nerve Root Compromise
    Sartoretti, Elisabeth
    Sartoretti, Thomas
    Schwenk, Arpad
    Alfieri, Alex
    Czell, David
    Wyss, Michael
    Wildi, Lukas
    Binkert, Christoph A.
    Sartoretti-Schefer, Sabine
    TOMOGRAPHY, 2022, 8 (01) : 257 - 266
  • [50] High Resolution 3D Fast Spin-Echo T1 Black-Blood Imaging for the Diagnosis of Giant Cell Arteritis
    Rodriguez, Christine
    Ben Hassen, Wagih
    Seners, Pierre
    Oppenheim, Catherine
    Regent, Alexis
    ARTHRITIS & RHEUMATOLOGY, 2019, 71