High-Resolution Maps of Magnetization Transfer with Inherent Correction for RF Inhomogeneity and T1 Relaxation Obtained from 3D FLASH MRI

被引:235
|
作者
Helms, Gunther [1 ]
Dathe, Henning [2 ]
Kallenberg, Kai [1 ,3 ]
Dechent, Peter [1 ]
机构
[1] Univ Med Gottingen, MR Forsch Neurol & Psychiat, D-37075 Gottingen, Germany
[2] AG Biomech, Abt Kieferorthopad, Gottingen, Germany
[3] Univ Med Gottingen, Abt Neuroradiol, Gottingen, Germany
关键词
magnetization transfer; relaxation; saturation; human brain; multiple sclerosis;
D O I
10.1002/mrm.21732
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
empirical equation for the magnetization transfer (MT) FLASH signal is derived by analogy to dual-excitation FLASH introducing a novel semiquantitative parameter for MT, the per centage saturation imposed by one MT pulse during TR. This parameter is obtained by a linear transformation of the inverse signal, using two reference experiments of proton density and T, weighting. The influence of sequence parameters on the MT saturation was studied. An 8.5-min protocol for brain imaging a 3 T was based on nonselective sagittal 3D-FLASH at 1.25 mm isotropic resolution using partial acquisition techniques (TRITE alpha = 25ms/4.9ms/5 degrees or 11 ms/4.9ms/15 degrees for the T-1 reference). 12.8 ms Gaussian MT pulse was applied 2.2 kHz off-resonance with 540 degrees flip angle. The MT saturation maps showed an excel lent contrast in the brain due to clearly separated distributiom for white and gray matter and cerebrospinal fluid. Within the limits of the approximation (excitation <15 degrees, TR/T-1 << 1) the MT term depends mainly on TR, the energy and offset of the MT pulse, but hardly on excitation and T, relaxation. It is inherently compensated for inhomogeneities of receive and transmit RF fields. The MT saturation appeared to be a sensitive parameter to depict MS lesions and alterations of normal-appearing white matter. Magn Reson Med 60:1396-1407, 2008. (C) 2008 Wiley Liss, Inc.
引用
收藏
页码:1396 / 1407
页数:12
相关论文
共 50 条
  • [31] Phase-based fast 3D high-resolution quantitative T2 MRI in 7 T human brain imaging
    Seginer, Amir
    Schmidt, Rita
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [32] Phase-based fast 3D high-resolution quantitative T2 MRI in 7 T human brain imaging
    Amir Seginer
    Rita Schmidt
    Scientific Reports, 12
  • [33] Feasibility and evaluation of dual-source transmit 3D imaging of the orbits: Comparison to high-resolution conventional MRI at 3T
    Seeger, Achim
    Schulze, Maximilian
    Schuettauf, Frank
    Klose, Uwe
    Ernemann, Ulrike
    Hauser, Till-Karsten
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (06) : 1150 - 1158
  • [34] Hypoglossal Nerve Lesions: The Role of a 3D IR-Prepped Fast SPGR High-Resolution 3T MRI Sequence
    Geng, Chengjun
    Lu, Zehua
    Xuan, Lulu
    Yin, Huikang
    Yang, Xiaoliang
    Yang, Liyue
    Xia, Xiaoliang
    Chu, Wei
    JOURNAL OF NEUROIMAGING, 2021, 31 (01) : 180 - 185
  • [35] HIGH RESOLUTION 3D T1-MAPPING OF PIG BLADDER WALL BY INTRAVESICAL CONTRAST ENHANCED MRI AT 3T
    Tyagi, Pradeep
    Moon, Chan-Hong
    Singh, Nishant
    Connell, Marc
    Maranchie, Jodi
    Chermansky, Christopher
    Yoshimura, Naoki
    Kaufman, Jonathan
    JOURNAL OF UROLOGY, 2021, 206 : E390 - E390
  • [36] Detection of Parkinson's Disease from 3T T1 Weighted MRI Scans Using 3D Convolutional Neural Network
    Chakraborty, Sabyasachi
    Aich, Satyabrata
    Kim, Hee-Cheol
    DIAGNOSTICS, 2020, 10 (06)
  • [37] Spontaneous Middle Cerebral Artery Dissection Demonstrated by High-Resolution T1-Weighted 3D Image
    Uemura, Masahiro
    Akaiwa, Yasuhisa
    Toriyabe, Masafumi
    Mashima, Takuya
    Terajima, Kenshi
    Shimohata, Takayoshi
    Igarashi, Hironaka
    Nakada, Tsutomu
    Nishizawa, Masatoyo
    CEREBROVASCULAR DISEASES, 2013, 36 (03) : 243 - 244
  • [38] Reconstruction of high-resolution 3D dose from matrix measurements: error detection capability of the COMPASS correction kernel method
    Godart, J.
    Korevaar, E. W.
    Visser, R.
    Wauben, D. J. L.
    van't Veld, A. A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (15): : 5029 - 5043
  • [39] Modeling the Influence of TR and Excitation Flip Angle on the Magnetization Transfer Ratio (MTR) in Human Brain Obtained From 3D Spoiled Gradient Echo MRI
    Helms, Gunther
    Dathe, Henning
    Dechent, Peter
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (01) : 177 - 185
  • [40] High-resolution multi-breath-held 3D volumetric T1 mapping acquisition: analysis of volume measurements of small structures using a respiratory motion phantom
    Keigo Kawaji
    Sui-Cheng Wang
    Akiko Tanaka
    Hui Wang
    Roberto Lang
    Amit R Patel
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)