Design and optimization of a spectrometer for high-resolution SD-OCT

被引:4
|
作者
Wang, Lulu [1 ]
Yu, Xiaojun [2 ]
Ge, Xin [1 ]
Wu, Xuan [1 ]
Wang, Xianghong [1 ]
Bo, En [1 ]
Wang, Nanshuo [1 ]
Liu, Xinyu [1 ]
Ni, Guangming [3 ]
Liu, Linbo [1 ]
机构
[1] Nanyang Technol Univ, Sch Elect & Elect Engn, Singapore 639798, Singapore
[2] Northwestern Polytech Univ, Sch Automat, Xian 710072, Shaanxi, Peoples R China
[3] Univ Elect Sci & Technol China, Sch Optoelect Informat, Chengdu 610054, Sichuan, Peoples R China
基金
中国国家自然科学基金; 英国医学研究理事会; 新加坡国家研究基金会;
关键词
optical coherence tomography; imaging systems; medical and biological imaging; medical optics instrumentation; OPTICAL COHERENCE TOMOGRAPHY; ULTRAHIGH-RESOLUTION; HIGH-SPEED;
D O I
10.1088/1612-202X/ab0a5d
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We report the design of a high-efficiency spectrometer for high-resolution spectral-domain optical coherence tomography (SD-OCT). The advantages of the proposed spectrometer are two-fold: first, we use a concave mirror instead of a camera lens (as typically used) as the focusing optics to both improve the transmission efficiency and eliminate chromatic aberrations; second, the efficiency of the proposed spectrometer is approximately 1.23 times that of a refractive optics-based spectrometer for an SD-OCT system, with comparable ranging depth and axial resolution. Both theoretical analyses and imaging experiments were conducted to characterize and validate the performance of the proposed spectrometer.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Agreement between Automated and Manual Corneal Thickness Mapping for Pachymetry, Epithelium, and Stroma from iVue SD-OCT and Avanti SD-OCT
    Wang, Xingwei
    Soules, Kelly A.
    Wolfson, Yulia
    Luh, Susan
    Hsiao, Yi-Sing
    Kjang, Ben
    Zhou, Qienyuan
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [32] Validity of Automated Choroidal Segmentation in SS-OCT and SD-OCT
    Zhang, Li
    Buitendijk, Gabrielle H. S.
    Lee, Kyungmoo
    Sonka, Milan
    Springelkamp, Henriet
    Hofman, Albert
    Vingerling, Johannes R.
    Mullins, Robert F.
    Klaver, Caroline C. W.
    Abramoff, Michael D.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (05) : 3202 - 3211
  • [33] SD-OCT of the Nerve Fiber Layer - Oct for Non-Ophthalmologists
    Augustin, Albert J.
    OPHTHALMOLOGICA, 2014, 232 : 12 - 13
  • [34] Design and implementation of a high-resolution, high-efficiency optical spectrometer
    Utter, SB
    López-Urrutia, JRC
    Beiersdorfer, P
    Träbert, E
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (11): : 3737 - 3741
  • [35] HIGH-RESOLUTION CRYSTAL SPECTROMETER
    BITTER, M
    VONGOELER, S
    GOLDMAN, M
    HILL, K
    HORTON, RW
    SAUTHOFF, N
    STODIEK, W
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1978, 23 (05): : 698 - 698
  • [36] The Prevalence of Cirrus SD-OCT Ganglion Cell Segmentation Errors in High Myopes
    Johung, Tessa
    Oakley, Jonathan
    Russako, Daniel
    Sabhlok, Sonny
    Li, Felix
    Chang, Robert
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [37] HIGH-RESOLUTION RAMAN SPECTROMETER
    NECHAEV, SY
    PONOMAREV, YN
    KVANTOVAYA ELEKTRONIKA, 1975, 2 (07): : 1400 - 1402
  • [38] High-Resolution Terahertz Spectrometer
    Klatt, Gregor
    Gebs, Raphael
    Schaefer, Hanjo
    Nagel, Michael
    Janke, Christof
    Bartels, Albrecht
    Dekorsy, Thomas
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2011, 17 (01) : 159 - 168
  • [39] HIGH-RESOLUTION NMR SPECTROMETER
    SAMITOV, YY
    AGANOV, AV
    VINOGRADOV, LI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1967, (06): : 1359 - +
  • [40] HIGH-RESOLUTION GRATING SPECTROMETER
    PORTO, SPS
    SZULE, A
    GUIMARAES, WON
    NETO, JRP
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1960, 50 (09) : 921 - 922