Design and optimization of a spectrometer for high-resolution SD-OCT

被引:4
|
作者
Wang, Lulu [1 ]
Yu, Xiaojun [2 ]
Ge, Xin [1 ]
Wu, Xuan [1 ]
Wang, Xianghong [1 ]
Bo, En [1 ]
Wang, Nanshuo [1 ]
Liu, Xinyu [1 ]
Ni, Guangming [3 ]
Liu, Linbo [1 ]
机构
[1] Nanyang Technol Univ, Sch Elect & Elect Engn, Singapore 639798, Singapore
[2] Northwestern Polytech Univ, Sch Automat, Xian 710072, Shaanxi, Peoples R China
[3] Univ Elect Sci & Technol China, Sch Optoelect Informat, Chengdu 610054, Sichuan, Peoples R China
基金
中国国家自然科学基金; 英国医学研究理事会; 新加坡国家研究基金会;
关键词
optical coherence tomography; imaging systems; medical and biological imaging; medical optics instrumentation; OPTICAL COHERENCE TOMOGRAPHY; ULTRAHIGH-RESOLUTION; HIGH-SPEED;
D O I
10.1088/1612-202X/ab0a5d
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We report the design of a high-efficiency spectrometer for high-resolution spectral-domain optical coherence tomography (SD-OCT). The advantages of the proposed spectrometer are two-fold: first, we use a concave mirror instead of a camera lens (as typically used) as the focusing optics to both improve the transmission efficiency and eliminate chromatic aberrations; second, the efficiency of the proposed spectrometer is approximately 1.23 times that of a refractive optics-based spectrometer for an SD-OCT system, with comparable ranging depth and axial resolution. Both theoretical analyses and imaging experiments were conducted to characterize and validate the performance of the proposed spectrometer.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] DESIGN OF A HIGH-RESOLUTION FOURIER-TRANSFORM SPECTROMETER
    PALMER, BA
    ENGLEMAN, R
    TESTERMAN, L
    BRAULT, J
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1983, 380 : 68 - 69
  • [22] Impact of high myopia on the performance of SD-OCT parameters to detect glaucoma
    Takuhei Shoji
    Yui Nagaoka
    Hiroki Sato
    Etsuo Chihara
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2012, 250 : 1843 - 1849
  • [23] Foveal choroidal thickness assessment with SD-OCT in high myopic glaucoma
    Chebil, A.
    Maamouri, R.
    Ben Abdallah, M.
    Ouderni, M.
    Chaker, N.
    El Matri, L.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2015, 38 (05): : 440 - 444
  • [24] Early Retinal Changes detected with SD-OCT
    Beutner, Andreas
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2015, 232 (07) : 820 - 820
  • [25] Detection of Glaucoma Progression by use of SD-OCT
    不详
    OPHTHALMOLOGE, 2016, 113 (12): : 1007 - 1007
  • [26] The Repeatability of Corneal Power Measurements with SD-OCT
    Wang, Yingjian
    Bagherinia, Homayoun
    Sha, Patricia
    Fard, Ali
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [27] Automatic montage of SD-OCT data sets
    Li, Ying
    Gregori, Giovanni
    Lam, Byron L.
    Rosenfeld, Philip J.
    OPTICS EXPRESS, 2011, 19 (27): : 26239 - 26248
  • [28] SD-OCT and autofluorescence characteristics of autoimmune retinopathy
    Pepple, Kathryn Lynn
    Cusick, Michael
    Jaffe, Glenn J.
    Mruthyunjaya, Prithvi
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2013, 97 (02) : 139 - 144
  • [29] High-resolution spectral domain optical coherence tomography (SD-OCT) in multiple sclerosis: the first follow-up study over two years
    Aboul-Enein, F.
    Serbecic, N.
    Beutelspacher, S.
    Vass, C.
    Kristoferitsch, W.
    Lassmann, H.
    Reitner, A.
    Schmidt-Erfurth, U.
    MULTIPLE SCLEROSIS JOURNAL, 2011, 17 : S258 - S259
  • [30] Human Cone Photoreceptors Investigated in vivo With SLO/OCT and SD-OCT
    Pircher, M.
    Sattmann, H.
    Prokesch, H.
    Schmoll, T.
    Baumann, B.
    Gotzinger, E.
    Leitgeb, R. A.
    Hitzenberger, C. K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)