Design and optimization of a spectrometer for high-resolution SD-OCT

被引:4
|
作者
Wang, Lulu [1 ]
Yu, Xiaojun [2 ]
Ge, Xin [1 ]
Wu, Xuan [1 ]
Wang, Xianghong [1 ]
Bo, En [1 ]
Wang, Nanshuo [1 ]
Liu, Xinyu [1 ]
Ni, Guangming [3 ]
Liu, Linbo [1 ]
机构
[1] Nanyang Technol Univ, Sch Elect & Elect Engn, Singapore 639798, Singapore
[2] Northwestern Polytech Univ, Sch Automat, Xian 710072, Shaanxi, Peoples R China
[3] Univ Elect Sci & Technol China, Sch Optoelect Informat, Chengdu 610054, Sichuan, Peoples R China
基金
中国国家自然科学基金; 英国医学研究理事会; 新加坡国家研究基金会;
关键词
optical coherence tomography; imaging systems; medical and biological imaging; medical optics instrumentation; OPTICAL COHERENCE TOMOGRAPHY; ULTRAHIGH-RESOLUTION; HIGH-SPEED;
D O I
10.1088/1612-202X/ab0a5d
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We report the design of a high-efficiency spectrometer for high-resolution spectral-domain optical coherence tomography (SD-OCT). The advantages of the proposed spectrometer are two-fold: first, we use a concave mirror instead of a camera lens (as typically used) as the focusing optics to both improve the transmission efficiency and eliminate chromatic aberrations; second, the efficiency of the proposed spectrometer is approximately 1.23 times that of a refractive optics-based spectrometer for an SD-OCT system, with comparable ranging depth and axial resolution. Both theoretical analyses and imaging experiments were conducted to characterize and validate the performance of the proposed spectrometer.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] High-resolution spectrometer: solution to the axial resolution and ranging depth trade-off of SD-OCT
    Marvdashti, Tahereh
    Lee, Hee Yoon
    Ellerbee, Audrey K.
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC SYSTEMS XI, 2013, 8572
  • [2] Significance of the SD-OCT
    Framme, C.
    OPHTHALMOLOGE, 2019, 116 (05): : 407 - 407
  • [3] Resolution of Acute Photoreceptor Damage as Revealed by Serial SD-OCT
    Sakai, Tsutomu
    Inaba, Mayumi
    Kohzaki, Kenichi
    Tsuneoka, Hiroshi
    OPTOMETRY AND VISION SCIENCE, 2013, 90 (05) : E142 - E146
  • [4] Comparison of EZ Loss Evaluation with Low- and High-resolution SD-OCT in Classic CLN2 Disease
    Huang, Wei Chieh
    Ohnsman, Christina
    Atiskova, Yevgeniya
    Dulz, Simon
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [5] Interpretation of RNFLT values in multiple sclerosis-associated acute optic neuritis using high-resolution SD-OCT device
    Serbecic, Nermin
    Beutelspacher, Sven C.
    Kircher, Karl
    Reitner, Andreas
    Schmidt-Erfurth, Ursula
    ACTA OPHTHALMOLOGICA, 2012, 90 (06) : 540 - 545
  • [6] Build Versus Buy: Considerations in SD-OCT System Design
    Rathmell, Cicely
    Biophotonics International, 2023, 30 (05): : 34 - 39
  • [7] Spectralis SD-OCT and Cirrus SD-OCT: RNFL Thickness Measurement Agreement and Diagnostic Performance in Glaucoma
    Beltran-Agullo, L.
    Roca-Obis, M.
    Ayala-Fuentes, E.
    Morilla-Grasa, A.
    Anton-Lopez, A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [8] Posterior microphthalmos: SD-OCT appearance
    Anagjoun, K.
    Ez-Zahraoui, M. R.
    Hajji, I.
    Moutaouakil, A.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2016, 39 (08): : 736 - 737
  • [9] Evaluation of Macular Thickness by SD-OCT
    Lam, Hee Hong
    Khaw, Gideon Keat Ween
    Khang, Tsung Fei
    Subrayan, Visvaraja
    OPHTHALMOLOGY, 2012, 119 (01) : 197 - 198
  • [10] ROLE OF SD-OCT IN OCULAR HYPERTENSION
    Anand, R.
    Solanki, Deepshikha
    Gupta, Sanchit
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (44): : 7604 - 7609