Accuracy Evaluation of NIM5 Cesium Fountain Clock

被引:6
|
作者
Liu Nian-Feng [1 ]
Fang Fang [1 ]
Chen Wei-Liang [1 ]
Lin Ping-Wei [1 ]
Wang Ping [1 ]
Liu Kun [1 ]
Suo Rui [1 ]
Li Tian-Chu [1 ]
机构
[1] Natl Inst Metrol, Beijing 100013, Peoples R China
基金
中国国家自然科学基金;
关键词
PRIMARY FREQUENCY STANDARD; SHIFT;
D O I
10.1088/0256-307X/30/1/010601
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The NIM5 fountain clock is the second fountain clock built at NIM (National Institute of Metrology, China), and has been operating stably and sub-continually since 2008. The fountain operates with a simple one-stage optical molasses to collect cold atoms, which reduces the collisional frequency shift dramatically. The fractional frequency uncertainty is estimated to be 2 x 10(-15). The typical frequency instability of 2.5 x 10(-14) is obtained at 10s. Comparisons with other fountain frequency standards worldwide demonstrate agreement within the stated uncertainties.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] The tentative application of optical generation of microwave on the fountain clock in NIM
    Dai, Shaoyang
    Fang, Fang
    Liu, Kun
    Chen, Weiliang
    Liu, Nianfeng
    Cao, Shiying
    Li, Tianchu
    2019 URSI ASIA-PACIFIC RADIO SCIENCE CONFERENCE (AP-RASC), 2019,
  • [22] Atomic clock with cesium fountain frequency standard
    Bauch, A
    PTB-MITTEILUNGEN, 1998, 108 (01): : 3 - 18
  • [23] Accuracy Evaluation of the KRISS-F1 Fountain Clock
    Eon, Park Sang
    Myoung-Sun, Heo
    Yong, Kwon Taeg
    Kurt, Gibble
    Sang-Bum, Lee
    Yong, Park Chang
    Won-Kyu, Lee
    Dai-Hyuk, Yu
    2014 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM (FCS), 2014, : 458 - +
  • [24] TOWARDS THE ESTABLISHMENT OF A CESIUM FOUNTAIN CLOCK AT CENAM
    Lopez-Romero, J. M.
    Lopez-Lopez, E. de Carlos L. S.
    Shtin, N.
    Espinosa O, M.
    Lizama P, L. A.
    2010 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS CPEM, 2010, : 78 - 79
  • [25] NIM5驾驭氢钟守时能力分析
    王玉琢
    徐倩
    刘昆
    房芳
    张爱敏
    仪器仪表学报, 2024, 45 (02) : 129 - 136
  • [26] The generation of new TA(NIM), which is steered by a NIM4 caesium fountain clock
    Gao Yuan
    Gao Xiaoxun
    Zhang Aimin
    Wang Weibo
    Ning Dayu
    Wang Chen
    Li Dawei
    Liu Xiaojin
    Liu Nianfeng
    Wang Ping
    Li Mingshou
    Lin Pingwei
    Chen Weiliang
    Lin Yige
    Li Tianchu
    METROLOGIA, 2008, 45 (06) : S34 - S37
  • [27] Design & preliminary results of NIM cesium fountain primary frequency standard
    Wang, Liji
    Wu, Changhua
    Huang, Bingying
    Li, Mingshou
    Qian, Jin
    Ji, Wangxi
    Proceedings of the Annual IEEE International Frequency Control Symposium, 1999, 1 : 30 - 33
  • [28] Frequency synthesis based on the cryogenic sapphire oscillator for the nim fountain clock
    Liu N.
    Dai S.
    Chen W.
    Liu K.
    Fang F.
    Li T.
    International Journal of Electrical Engineering, 2020, 27 (04): : 125 - 130
  • [29] The design and test of microwave cavity of Cesium fountain clock
    Fuh, CN
    Yao, A
    Huang, MS
    Kou, CS
    IMTC/97 - IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE: SENSING, PROCESSING, NETWORKING, PROCEEDINGS VOLS 1 AND 2, 1997, : 480 - 481
  • [30] Compact Optical System For Cesium Atomic Fountain Clock
    Chen, Jiang
    Ruan, Jun
    Shi, Junru
    Yu, Fengxiang
    Zhang, Hui
    Wang, Xinliang
    Zhang, Shougang
    8TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGY: OPTICAL TEST, MEASUREMENT TECHNOLOGY, AND EQUIPMENT, 2016, 9684