Development of quantitative mass spectrometric immunoassay for serum amyloid A

被引:20
|
作者
Trenchevska, Olgica [1 ]
Yassine, Hussein N. [2 ]
Borges, Chad R. [1 ]
Nelson, Randall W. [1 ]
Nedelkov, Dobrin [1 ]
机构
[1] Arizona State Univ, Biodesign Inst, 727 E Tyler St, Tempe, AZ 85287 USA
[2] Univ Southern Calif, Dept Med, Los Angeles, CA USA
关键词
Baseline concentration; inflammation biomarker; mass spectrometry; polymorphism; posttranslational modifications; proteoforms; C-REACTIVE PROTEIN; CORONARY-ARTERY-DISEASE; SYSTEMIC AA-AMYLOIDOSIS; ACUTE-PHASE PROTEIN; HUMAN-PLASMA; GENE FAMILY; SAA; CHOLESTEROL; ISOFORMS; VARIANTS;
D O I
10.1080/1354750X.2016.1201533
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Objective: Proteins can exist as multiple proteoforms in vivo that can have important roles in physiological and pathological states. Methods: We present the development and characterization of mass spectrometric immunoassay (MSIA) for quantitative determination of serum amyloid A (SAA) proteoforms. Results: Intra-and inter-day precision revealed CVs <10%. Against existing SAA ELISA, the developed MSIA showed good correlation according to the Altman-Bland plot. Individual concentrations of the SAA proteoforms across a cohort of 170 samples revealed 7 diverse SAA polymorphic types and 12 different proteoforms. Conclusion: The new SAA MSIA enables parallel analysis of SAA polymorphisms and quantification of all expressed SAA proteoforms, in a high-throughput and time-efficient manner.
引用
收藏
页码:743 / 751
页数:9
相关论文
共 50 条
  • [41] Development of a quantitative immunoassay for Saccharopolyspora antigens
    Zahradnik, E.
    Sander, I.
    van Kampen, V.
    Bruning, T.
    Raulf, M.
    ALLERGOLOGIE, 2017, 40 (08) : 306 - 310
  • [42] DEVELOPMENT AND APPLICATION OF A QUANTITATIVE IMMUNOASSAY FOR PAF
    BALDO, BA
    SMAL, MA
    HARLE, DG
    REDMOND, JW
    PROSTAGLANDINS, 1987, 34 (02): : 195 - 195
  • [43] Highly sensitive and multiplexed mass spectrometric immunoassay techniques and clinical applications
    Xu, Shuting
    Liu, Huwei
    Bai, Yu
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (18) : 5121 - 5138
  • [44] Highly sensitive and multiplexed mass spectrometric immunoassay techniques and clinical applications
    Shuting Xu
    Huwei Liu
    Yu Bai
    Analytical and Bioanalytical Chemistry, 2022, 414 : 5121 - 5138
  • [45] Detection and quantification of β-2-microglobulin using mass spectrometric immunoassay
    Tubbs, KA
    Nedelkov, D
    Nelson, RW
    ANALYTICAL BIOCHEMISTRY, 2001, 289 (01) : 26 - 35
  • [46] Mass Spectrometric Immunoassay for Insulin-Like Growth Factor 1
    Nedelkov, Dobrin
    Niederkofler, Eric
    Phillips, David
    Krastins, Bryan
    Kiernan, Urban
    Tubbs, Kemmons
    Lopez, Mary
    FASEB JOURNAL, 2013, 27
  • [47] High-throughput protein characterization using mass spectrometric immunoassay
    Kiernan, UA
    Tubbs, KA
    Gruber, K
    Nedelkov, D
    Niederkofler, EE
    Williams, P
    Nelson, RW
    ANALYTICAL BIOCHEMISTRY, 2002, 301 (01) : 49 - 56
  • [48] Software development for mass spectrometric analysis
    Hart, KJ
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1996, 10 (03) : 393 - 398
  • [49] A novel immunoassay for quantitative drug abuse screening in serum
    Schumacher, Sarah
    Seitz, Harald
    JOURNAL OF IMMUNOLOGICAL METHODS, 2016, 436 : 34 - 40
  • [50] A METHOD FOR QUANTITATIVE MASS-SPECTROMETRIC ANALYSIS OF SOLUTIONS
    SAPRYKIN, AI
    KOVALEV, YV
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1991, 46 (09): : 1236 - 1240