Effects of BAC-filtration, disinfection, and temperature on water quality in simulated reclaimed water distribution systems

被引:0
|
作者
Zhu, Ni [1 ]
Ghosh, Sudeshna [1 ]
Strom, Laurel [2 ]
Pruden, Amy [1 ]
Edwards, Marc A. [1 ]
机构
[1] Virginia Tech, Via Dept Civil & Environm Engn, Blacksburg, VA 24061 USA
[2] CDM Smith, 14432 SE Eastgate Way,Suite 100, Bellevue, WA 98007 USA
基金
美国国家科学基金会;
关键词
AMMONIA-OXIDIZING ARCHAEA; BACTERIAL COMMUNITY STRUCTURE; TREATMENT-PLANT; BIOFILM DEVELOPMENT; ORGANIC-MATTER; NITRIFICATION; CHLORINE; CARBON; REGROWTH; DECAY;
D O I
10.1039/d0ew00581a
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The distinct characteristics of reclaimed versus potable water have important implications for design and operation of reclaimed water distribution systems (RWDSs). Here we operated six simulated RWDSs in parallel to determine the effects of feed water treatment (with and without biologically-active carbon (BAC) filtration) and residual disinfectants (chlorine, chloramine, or no residual) on the distributed water quality. Following a six-month acclimation period, the experimental conditions were implemented over 2 years of operation, with a temperature regime of 14 degrees C -> 22 degrees C -> 30 degrees C -> 22 degrees C -> 14 degrees C imposed to simulate seasonal variation. Comprehensive water chemistry profiling and microbial sampling were conducted over a range of water ages (0 d, 1 d, 2.5 d and 5 d) along the RWDSs at each temperature phase. When >= 22 degrees C, RWDSs became more vulnerable to deterioration of water quality due to nitrification, as evidenced by accelerated chloramine decay and increased relative abundance of nitrifier genera and functional genes. Contrary to conventional experience in potable water distribution, chlorine generally became more persistent than chloramine from the first 22 degrees C phase onwards. Enhanced persistence of chlorine was accompanied by increased biological stability (i.e., lower cell counts and reduced dissolved oxygen demand). BAC filtration initially improved water quality (i.e., lower total organic carbon and biomass, longer persistence of disinfectants), but benefits diminished over long term distribution system operation. Taxonomic and functional metagenomic profiles revealed that chlorine had the strongest selective effect compared to both chloramine and no residual, particularly for the unfiltered condition. The long-term operation strategy employed here enabled evaluation of distribution system management practices and their interactive effects as the RWDSs experienced temperature shifts and aged.
引用
收藏
页码:3106 / 3120
页数:15
相关论文
共 50 条
  • [41] Water quality parameter estimation for water distribution systems
    Pasha, M. F. K.
    Lansey, K.
    CIVIL ENGINEERING AND ENVIRONMENTAL SYSTEMS, 2009, 26 (03) : 231 - 248
  • [42] Monitoring water quality in water supply and distribution systems
    Papadimitrakis, YA
    ADVANCES IN WATER SUPPLY MANAGEMENT, 2003, : 441 - 450
  • [43] Water quality modelling for drinking water distribution systems
    Jegatheesan, V
    Kastl, G
    Fisher, I
    Chandy, J
    Angles, M
    MODSIM 2003: INTERNATIONAL CONGRESS ON MODELLING AND SIMULATION, VOLS 1-4: VOL 1: NATURAL SYSTEMS, PT 1; VOL 2: NATURAL SYSTEMS, PT 2; VOL 3: SOCIO-ECONOMIC SYSTEMS; VOL 4: GENERAL SYSTEMS, 2003, : 332 - 337
  • [44] Analysis of water quality characteristic for water distribution systems
    Wang, Yumin
    Zhu, Guangcan
    Yang, Zhonglian
    JOURNAL OF WATER REUSE AND DESALINATION, 2019, 9 (02): : 152 - 162
  • [45] Assessment on reliability of water quality in water distribution systems
    伍悦滨
    田海
    王龙岩
    Journal of Harbin Institute of Technology, 2004, (05) : 481 - 484
  • [46] Innovative microbial water quality management in water distribution systems using in-pipe hydropowered UV disinfection: envisioning futuristic water-energy systems
    Ma, Daniel
    Belloni, Clarissa
    Hull, Natalie M.
    ENVIRONMENTAL TECHNOLOGY, 2025, 46 (07) : 1045 - 1061
  • [47] Water quality effects on clogging rates during reclaimed water ASR in a carbonate aquifer
    Pavelic, Paul
    Dillon, Peter J.
    Barry, Karen E.
    Vanderzalm, Joanne L.
    Correll, Raymond L.
    Rinck-Pfeiffer, Stephanie M.
    JOURNAL OF HYDROLOGY, 2007, 334 (1-2) : 1 - 16
  • [48] Optimal decoupling of booster disinfection systems in water distribution networks
    Uber, JG
    Polycarpou, MM
    Subramaniam, P
    WATER RESOURCES AND THE URBAN ENVIRONMENT, 1998, : 297 - 302
  • [49] Modeling the Fate of Disinfection By-Products in Water Distribution Systems
    Boano, F.
    Fiore, S.
    Revelli, R.
    16TH WATER DISTRIBUTION SYSTEM ANALYSIS CONFERENCE (WDSA2014): URBAN WATER HYDROINFORMATICS AND STRATEGIC PLANNING, 2014, 89 : 255 - 261
  • [50] Influence of disinfection processes on biofilm formation in water distribution systems
    Lund, Vidar
    Ormerod, Kari
    Water Research, 1995, 29 (04):