Effects of BAC-filtration, disinfection, and temperature on water quality in simulated reclaimed water distribution systems

被引:0
|
作者
Zhu, Ni [1 ]
Ghosh, Sudeshna [1 ]
Strom, Laurel [2 ]
Pruden, Amy [1 ]
Edwards, Marc A. [1 ]
机构
[1] Virginia Tech, Via Dept Civil & Environm Engn, Blacksburg, VA 24061 USA
[2] CDM Smith, 14432 SE Eastgate Way,Suite 100, Bellevue, WA 98007 USA
基金
美国国家科学基金会;
关键词
AMMONIA-OXIDIZING ARCHAEA; BACTERIAL COMMUNITY STRUCTURE; TREATMENT-PLANT; BIOFILM DEVELOPMENT; ORGANIC-MATTER; NITRIFICATION; CHLORINE; CARBON; REGROWTH; DECAY;
D O I
10.1039/d0ew00581a
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The distinct characteristics of reclaimed versus potable water have important implications for design and operation of reclaimed water distribution systems (RWDSs). Here we operated six simulated RWDSs in parallel to determine the effects of feed water treatment (with and without biologically-active carbon (BAC) filtration) and residual disinfectants (chlorine, chloramine, or no residual) on the distributed water quality. Following a six-month acclimation period, the experimental conditions were implemented over 2 years of operation, with a temperature regime of 14 degrees C -> 22 degrees C -> 30 degrees C -> 22 degrees C -> 14 degrees C imposed to simulate seasonal variation. Comprehensive water chemistry profiling and microbial sampling were conducted over a range of water ages (0 d, 1 d, 2.5 d and 5 d) along the RWDSs at each temperature phase. When >= 22 degrees C, RWDSs became more vulnerable to deterioration of water quality due to nitrification, as evidenced by accelerated chloramine decay and increased relative abundance of nitrifier genera and functional genes. Contrary to conventional experience in potable water distribution, chlorine generally became more persistent than chloramine from the first 22 degrees C phase onwards. Enhanced persistence of chlorine was accompanied by increased biological stability (i.e., lower cell counts and reduced dissolved oxygen demand). BAC filtration initially improved water quality (i.e., lower total organic carbon and biomass, longer persistence of disinfectants), but benefits diminished over long term distribution system operation. Taxonomic and functional metagenomic profiles revealed that chlorine had the strongest selective effect compared to both chloramine and no residual, particularly for the unfiltered condition. The long-term operation strategy employed here enabled evaluation of distribution system management practices and their interactive effects as the RWDSs experienced temperature shifts and aged.
引用
收藏
页码:3106 / 3120
页数:15
相关论文
共 50 条
  • [21] Effects of chlorination/chlorine dioxide disinfection on biofilm bacterial community and corrosion process in a reclaimed water distribution system
    Zhang, Haiya
    Tian, Yimei
    Kang, Mengxin
    Chen, Chao
    Song, Yarong
    Li, Han
    CHEMOSPHERE, 2019, 215 : 62 - 73
  • [22] SMALL WATER DISTRIBUTION SYSTEM DISINFECTION BY-PRODUCT CONTROL: WATER QUALITY MANAGEMENT USING STORAGE SYSTEMS
    Poleneni, Sandhya Rao
    Inniss, Enos C.
    INTERNATIONAL JOURNAL OF GEOMATE, 2015, 9 (17): : 1365 - 1369
  • [23] It's getting hot in here: Effects of heat on temperature, disinfection, and opportunistic pathogens in drinking water distribution systems
    Furst, Kirin E.
    Graham, Katherine E.
    Weisman, Richard J.
    Adusei, Kadmiel B.
    WATER RESEARCH, 2024, 260
  • [24] Distribution Characteristics of Disinfection Byproducts in Drinking Water Distribution Systems of Different Disinfection Methods
    Wang H.
    Yu W.
    Hu Y.
    Cai X.
    Pang W.
    Tongji Daxue Xuebao/Journal of Tongji University, 2023, 51 (10): : 1518 - 1526
  • [25] Effects of reclaimed water irrigation upon soil quality
    Gao, Jun
    Wang, Huixiao
    Liu, Haijun
    Yin, Jian
    Zhao, Xuan
    PROGRESS IN ENVIRONMENTAL SCIENCE AND ENGINEERING, PTS 1-4, 2013, 610-613 : 3022 - 3026
  • [26] Effects of simulated solar disinfection of water on infectivity of Salmonella typhimurium
    Smith, RJ
    Kehoe, SC
    McGuigan, KG
    Barer, MR
    LETTERS IN APPLIED MICROBIOLOGY, 2000, 31 (04) : 284 - 288
  • [27] Effects of Reclaimed Water on the Growth and Fruit Quality of Cucumber
    Chen, Feng-Wen
    Liu, Chen-Wuing
    IRRIGATION AND DRAINAGE, 2015, 64 (03) : 370 - 377
  • [28] Distribution and generation characteristics of halogenated acetic acids disinfection by-products in reclaimed water
    Wang, Juncheng
    Song, Jina
    DESALINATION AND WATER TREATMENT, 2023, 294 : 120 - 128
  • [29] Effects of chlorine dose on the composition and characteristics of chlorinated disinfection byproducts in reclaimed water
    Liang, Jun-Kun
    Lu, Yao
    Song, Zhi-Min
    Ye, Bei
    Wu, Qian-Yuan
    Hu, Hong-Ying
    SCIENCE OF THE TOTAL ENVIRONMENT, 2022, 824
  • [30] Water quality monitoring in membrane filtration systems
    Abogrean, EM
    Boerlage, SFE
    Kennedy, MD
    El-Azizi, IM
    Galjaard, G
    Schippers, JS