Effect of Air Exposure and Suction on Blood Cell Activation and Hemolysis in an In Vitro Cardiotomy Suction Model

被引:30
|
作者
El-Sabbagh, Ahmed M. [1 ]
Toomasian, Cory J. [1 ]
Toomasian, John M. [1 ]
Ulysse, Guerlain [1 ]
Major, Terry [1 ]
Bartlett, Robert H. [1 ]
机构
[1] Univ Michigan, Extracorporeal Life Support Lab, Dept Surg, Ann Arbor, MI 48109 USA
关键词
leukocytes; hemolysis; inflammatory mediators; cardiopulmonary bypass; platelets; SYSTEMIC INFLAMMATORY RESPONSE; CARDIOPULMONARY BYPASS; PLATELET ACTIVATION; SURGERY; DEVICE; TRAUMA;
D O I
10.1097/MAT.0b013e31829f0e6e
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cardiopulmonary bypass (CPB) elicits a systemic inflammatory response. The cause may include surface-induced leukocyte activation and hemolysis. A study was designed to describe the effects of both suction and an air-blood interface independently and in combination on leukocyte and platelet activation, and hemolysis in an in vitro model. Fresh human blood was drawn and tested in four different conditions including control (A), 10 minutes of -600 mm Hg suction (B), 10 minutes of blood exposure to room air at 100 ml/min (C), and 10 minutes of simultaneous suction and air flow (D). Samples were analyzed by flow cytometry (platelets and leukocytes) and plasma-free hemoglobin (PFHb). Leukocyte CD11b expression and platelet P-selectin (CD62P) were analyzed by flow cytometry. In comparison with baseline, granulocytes were significantly activated by air (group C, p = 0.0029) and combination (group D, p = 0.0123) but not by suction alone (group B). Monocytes and platelets were not significantly activated in any group. The PFHb increased significantly in group C (p < 0.001) and group D (p < 0.001). This study suggests that the inflammatory response and associated hemolysis during CPB may be related to air exposure, which could be reduced by minimizing the air exposure of air to blood during cardiotomy suction.
引用
收藏
页码:474 / 479
页数:6
相关论文
共 50 条
  • [31] Effect of an air-suction nozzle on yarn hairiness and quality
    Jeon, BS
    TEXTILE RESEARCH JOURNAL, 2000, 70 (11) : 1019 - 1024
  • [32] Effect of forceful suction and air disinfection machines on aerosol removal
    Du, Yaru
    Zhao, Fei
    Tao, Ran
    Liu, Bing
    BMC ORAL HEALTH, 2023, 23 (01)
  • [33] Effect of forceful suction and air disinfection machines on aerosol removal
    Yaru Du
    Fei Zhao
    Ran Tao
    Bing Liu
    BMC Oral Health, 23
  • [34] Effect of boundary inlet pressure upon an air suction system
    Wei, Mingshan
    Ma, Chaochen
    Wang, Qiao
    Neiranji Gongcheng/Chinese Internal Combustion Engine Engineering, 2003, 24 (03):
  • [35] Suction detection and suction suppression of centrifugal blood pump based on the FFT-GAPSO-LSTM model and speed modulation
    Liu, Xin
    Qu, Hongyi
    Huang, Chuangxin
    Meng, Lingwei
    Chen, Qi
    Wang, Qiuliang
    HELIYON, 2024, 10 (04)
  • [36] THE EFFECT OF EPINEPHRINE ON BLOOD-LOSS DURING SUCTION LIPECTOMY
    COURTISS, EH
    KANTER, MA
    KANTER, WR
    RANSIL, BJ
    PLASTIC AND RECONSTRUCTIVE SURGERY, 1991, 88 (05) : 801 - 803
  • [37] EFFECT OF MYOCARDIAL PROTECTION ON PLASMA HISTAMINE IN THE CARDIOTOMY SUCTION EFFLUENT DURING CARDIOPULMONARY BYPASS IN OPEN-HEART-SURGERY
    MAN, WK
    MARATH, A
    OJUKWU, J
    DEVERALL, P
    TAYLOR, KM
    AGENTS AND ACTIONS, 1993, 38 : C275 - C277
  • [38] The coupled effect of suction and net stress on the air permeability of compacted soils
    Roy, S.
    Rajesh, S.
    GEOTECHNIQUE LETTERS, 2020, 10 (01) : 50 - 56
  • [39] Smart suction device for less blood trauma: a comparison with Cell Saver
    Mueller, XH
    Tevaearai, HT
    Horisberger, J
    Augstburger, M
    Boone, Y
    von Segesser, LK
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2001, 19 (04) : 507 - 511
  • [40] A Gaussian Mixture Model to Detect Suction Events in Rotary Blood Pumps
    Tzallas, Alexandros T.
    Rigas, George
    Karvounis, Evaggelos C.
    Tsipouras, Markos G.
    Goletsis, Yorgos
    Zielinski, Krzysztof
    Fresiello, Libera
    Fotiadis, Dimitrios I.
    Trivella, Maria G.
    IEEE 12TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS & BIOENGINEERING, 2012, : 127 - 131