Effect of Air Exposure and Suction on Blood Cell Activation and Hemolysis in an In Vitro Cardiotomy Suction Model

被引:30
|
作者
El-Sabbagh, Ahmed M. [1 ]
Toomasian, Cory J. [1 ]
Toomasian, John M. [1 ]
Ulysse, Guerlain [1 ]
Major, Terry [1 ]
Bartlett, Robert H. [1 ]
机构
[1] Univ Michigan, Extracorporeal Life Support Lab, Dept Surg, Ann Arbor, MI 48109 USA
关键词
leukocytes; hemolysis; inflammatory mediators; cardiopulmonary bypass; platelets; SYSTEMIC INFLAMMATORY RESPONSE; CARDIOPULMONARY BYPASS; PLATELET ACTIVATION; SURGERY; DEVICE; TRAUMA;
D O I
10.1097/MAT.0b013e31829f0e6e
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cardiopulmonary bypass (CPB) elicits a systemic inflammatory response. The cause may include surface-induced leukocyte activation and hemolysis. A study was designed to describe the effects of both suction and an air-blood interface independently and in combination on leukocyte and platelet activation, and hemolysis in an in vitro model. Fresh human blood was drawn and tested in four different conditions including control (A), 10 minutes of -600 mm Hg suction (B), 10 minutes of blood exposure to room air at 100 ml/min (C), and 10 minutes of simultaneous suction and air flow (D). Samples were analyzed by flow cytometry (platelets and leukocytes) and plasma-free hemoglobin (PFHb). Leukocyte CD11b expression and platelet P-selectin (CD62P) were analyzed by flow cytometry. In comparison with baseline, granulocytes were significantly activated by air (group C, p = 0.0029) and combination (group D, p = 0.0123) but not by suction alone (group B). Monocytes and platelets were not significantly activated in any group. The PFHb increased significantly in group C (p < 0.001) and group D (p < 0.001). This study suggests that the inflammatory response and associated hemolysis during CPB may be related to air exposure, which could be reduced by minimizing the air exposure of air to blood during cardiotomy suction.
引用
收藏
页码:474 / 479
页数:6
相关论文
共 50 条
  • [21] The effect of cardiotomy suction on the brain injury marker S100β alter cardiopulmonary bypass
    Anderson, RE
    Hansson, LC
    Liska, J
    Settergren, G
    Vaage, J
    ANNALS OF THORACIC SURGERY, 2000, 69 (03): : 847 - 850
  • [22] The effect of a novel turbulence-controlled suction system in the prevention of hemolysis and platelet dysfunction in autologous surgery blood
    Budde, Holger
    Riggert, Joachim
    Vormfelde, Steffen
    Tirilomis, Theodor
    Friedrich, Martin G.
    PERFUSION-UK, 2019, 34 (01): : 58 - 66
  • [23] Cell salvage of cardiotomy suction blood improves the balance between pro- and anti-inflammatory cytokines after cardiac surgery
    Gabel, Jakob
    Westerberg, Martin
    Bengtsson, Anders
    Jeppsson, Anders
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2013, 44 (03) : 506 - 511
  • [24] Suction-induced hemolysis at various vacuum pressures: Implications for intraoperative blood salvage
    Gregoretti, S
    TRANSFUSION, 1996, 36 (01) : 57 - 60
  • [25] Pericardial suction blood separation attenuates inflammatory response and hemolysis after cardiopulmonary bypass
    Skrabal, Christian A.
    Khosravi, Amir
    Choi, Yeong H.
    Kaminski, Alexander
    Westphal, Bernd
    Steinhoff, Gustav
    Liebold, Andreas
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2006, 40 (04) : 219 - 223
  • [26] Effect of Vibration Conditions on the Seed Suction Performance of an Air-Suction Precision Seeder for Small Seeds
    Wang, Yu
    Zhang, Wenhang
    Luo, Xiwen
    Zang, Ying
    Ma, Ligang
    Zhang, Wenpeng
    Liu, Jiahao
    Zeng, Shan
    AGRICULTURE-BASEL, 2024, 14 (04):
  • [27] EFFECTS OF INFUSION OF CARDIOTOMY SUCTION BLOOD DURING EXTRACORPOREAL-CIRCULATION FOR CORONARY-ARTERY BYPASS SURGERY
    OKIES, JE
    GOODNIGHT, SH
    LITCHFORD, B
    CONNELL, RS
    STARR, A
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1977, 74 (03): : 440 - 444
  • [28] EFFECT OF SUCTION ON BLOOD-FLOW IN ISCHAEMIC LIMBS
    SMYTH, CN
    LANCET, 1969, 2 (7622): : 657 - &
  • [29] REDUCED PLATELET ACTIVATION AND IMPROVED HEMOSTASIS AFTER CONTROLLED CARDIOTOMY SUCTION DURING CLINICAL MEMBRANE-OXYGENATOR PERFUSIONS
    BOONSTRA, PW
    VANIMHOFF, GW
    EYSMAN, L
    KOOTSTRA, GJ
    VANDERHEIDE, JNH
    KARLICZEK, GF
    WILDEVUUR, CRH
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1985, 89 (06): : 900 - 906
  • [30] Effect of suction air pressure in friction spinning on yarn properties
    Konda, F
    Okamura, M
    Merati, AA
    TEXTILE RESEARCH JOURNAL, 1996, 66 (07) : 446 - 452